Optimisasi Plantwide Control pada Naphta Hydrotreater Refinery Oil and Gas Plant

Hidayaturrahman, Andi Naufal (2023) Optimisasi Plantwide Control pada Naphta Hydrotreater Refinery Oil and Gas Plant. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 02311940000027-Undergraduate_Thesis.pdf] Text
02311940000027-Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 October 2025.

Download (2MB) | Request a copy

Abstract

Dalam beberapa tahun terakhir ini Indonesia memiliki kebutuhan akan bahan bakar minyak yang selalu lebih tinggi dibandingkan dengan produksi yang dihasilkan dari pabrik dalam negeri. Minyak mentah yang diambil melalui proses eksplorasi tentunya mengandung banyak senyawa ataupun zat yang tidak diinginkan sehingga diperlukan adanya beberapa proses pengolahan agar minyak mentah tadi memiliki nilai jual yang tinggi dan dapat digunakan dengan aman oleh konsumen. Salah satu proses penting dalam proses pengolahan minyak dan gas bumi adalah proses treating. Proses ini dilakukan pada plant yang bernama Naphta Hydrotreater. Plant ini memiliki tugas dan fungsi untuk menghilangkan impuritas-impuritas yang terkandung didalam Naphta seperti sulfur, nitrogen, dan lainnya. Nantinya produk dari Naphta Hydrotreater ini akan menjadi feed bagi plant Platforming Unit yang menghasilkan bahan bakar minyak gasoline. Untuk memaksimalkan kinerja dari plant agar energi yang digunakan tidak berlebihan, menjaga stabilitas plant, dan meningkatkan profit maka dalam penelitian ini digunakan metode kontrol plantwide untuk menjaga kestabilan plant dan memaksimalkan profit. Perancangan PWC yang dirancang pada plant Naphta Hydrotreater berhasil meningkatkan stabilitas dari proses yang ditunjukkan dengan maximum overshoot, error steady state, settling time, dan integral absolute error yang lebih kecil jika dibandingkan ketika plant yang hanya diterapkan metode pengendalian PID. Saat laju produksi tidak stabil baik mengalami peningkatan maupun penururnan, plant yang diterapkan metode PWC dapat menghemat penggunaan energi sebesar 112 kWh dan 692 kWh dibandingkan dengan metode pengendalian PID. Dari segi ekonomi, saat produksi naik metode PWC meningkatkan keuntungan hingga 20.877.747 IDR/jam dan saat produksi turun meningkatkan keuntungan sebesar 18.340.914 IDR/jam dibandingkan dengan plant ketika hanya menggunakan pengendali PID saja.
=================================================================================================================================
In recent years, Indonesia has had a higher demand for petroleum fuels compared to the production generated by domestic refineries. Crude oil extracted through exploration processes naturally contains numerous unwanted compounds and substances, necessitating several refining processes to enhance its market value and ensure safe usage by consumers. One essential process in oil and gas refining is the treating process, which takes place in a plant called Naphta Hydrotreater. This plant's task and function are to remove impurities present in Naphta, such as sulfur, nitrogen, and others. The resulting product from Naphta Hydrotreater serves as feed for the Platforming Unit plant, which produces petroleum fuels with an octane rating of 92. To maximize the performance of the plant, ensuring that energy usage is not excessive, maintaining plant stability, and increasing profit, this study utilizes plantwide control (PWC) methodology. The PWC design implemented in the Naphta Hydrotreater plant successfully enhances process stability, as indicated by reduced maximum overshoot, steadystate error, settling time, and integral absolute error compared to a plant employing only PID control. When the production rate is unstable, experiencing both increases and decreases, the PWC method saves energy consumption by 112 kWh and 692 kWh compared to PID control. Economically, during production increases, the PWC method increases profits by 20.877.747 IDR per hour, and during production decreases, it increases profits by 18.340.914 IDR per hour hour compared to using PID control alone.

Item Type: Thesis (Other)
Uncontrolled Keywords: Energy, Plantwide Control, Energi, Naphta Hydrotreater, Kontrol Plantwide
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ222 Supervisory control systems.
Divisions: Faculty of Industrial Technology and Systems Engineering (INDSYS) > Physics Engineering > 30201-(S1) Undergraduate Thesis
Depositing User: Hidayaturrahman Andi Naufal
Date Deposited: 04 Aug 2023 06:41
Last Modified: 30 Aug 2023 01:09
URI: http://repository.its.ac.id/id/eprint/101951

Actions (login required)

View Item View Item