Aldiva, Fhadila Putri (2023) Simulasi Kinerja Sistem AC Hemat Energi Menggunakan Phase Change Material (PCM). Other thesis, Institut Teknologi Sepuluh Nopember.
Text
5019211178-Undergraduate_Thesis.pdf - Accepted Version Restricted to Repository staff only until 1 September 2025. Download (3MB) | Request a copy |
Abstract
AC (Air Conditioner) merupakan sebuah pendingin ruangan yang biasanya digunakan pada bangunan untuk mengatur suhu udara ruangan serta kelembapan ruangan. Jumlah penggunaan AC pada bangunan saat ini semakin meningkat dikarenakan suhu atmosfer yang semakin panas. Dengan meningkatnya jumlah penggunaan AC menyebabkan nilai energi di dunia semakin meningkat pula, oleh sebab itu penelitian ini dilakukan untuk menciptakan AC hemat energi yang membantu mengurangi penggunaan energi. Hal ini dapat dilakukan dengan penambahan phase change material (PCM), dimana PCM merupakan material yang menyimpan energi thermal dengan memanfaatkan fenomena perubahaan fasa alaminya dengan menjaga suhu sekitarnya dengan menyimpan panas laten dalam jumlah besar. Dengan melakukan simulasi menggunakan software aspen HYSYS dan CFD Ansys. Dengan model yang telah disimulasikan pada aspen hysys didapatkan nilai COP pada AC konvensional lebih
rendah jika dibandingkan dengan nilai COP pada AC Hybrid, yang mana hal tersebut dapat menyatakan bahwa AC hybrid lebih hemat dalam penggunaan energi dibandingkan AC Konvensional, dengan nilai COP AC konvensional sebesar 6,4 sedangkan untuk AC Hybrid dengan Freon 50% ke PCM Chamber 6,86, Freon 40% ke PCM Chamber 6,74, dan Freon 30% ke PCM Chamber adalah 6,62. Lama waktu pembekuan PCM pada variasi aliran berbeda, semakin banyak aliran Freon ke PCM Chamber semakin sedikit waktu yang dibutuhkan untuk proses pembekuan PCM, sebagaimana dengan data aliran PCM 50% adalah 8343.34 detik atau 2 jam 31 menit, aliran PCM 40% adalah 8668.30 detik atau 2 jam 40 menit, dan untuk aliran PCM 30% adalah 9017.99 detik atau 2 jam 50 menit. Pada AC konvensional lama proses pendinginan ruangan dengan set suhu 20 oC dalam 5 menit didapatkan rata-rata suhu di ruangan adalah 23 oC sedangkan pada AC Hybrid lama proses pendinginan ruangan dengan set suhu 20 oC dalam waktu 5 menit adalah 22,57 oC. Waktu yang dibutuhkan untuk mendingkan AC konvensional dan AC hybrid tidak begitu jauh, namun AC Konvensional dapat mendinginkan lebih cepat jika dibandingkan dengan AC Hybrid
====================================================================================================================================
AC (Air Conditioner) that is usually used in buildings to regulate room air temperature and room humidity. The amount of AC use in buildings is currently increasing due to increasingl hot atmospheric temperaturs. With the increasing number of AC uses, the value of energy in the world is also increasing, therefore this research is carried out to create energyefficient air cinditioners that help reduce energy use. This can be done with the addition of phase change material (PCM), where PCM is a material that stores thermal energy by utilizing its natural phase change phenomenon by maintaining the surrounding temperatur by storing large amounts of latent heat. By simulating using aspen HYSYS dan ansys CFD software. With the model that has been simulated on aspen hysys, it is found that the COP vale of conventional AC is lower when compared to the COP value of hybrid AC, which can state that hybrid AC is more efficient in energy use than conventional AC, with a conventional AC COP value is 6,4 while for Hybrid AC with 50% Freon to the PCM Chamber 6.86, 40% Freon to the PCM Chamber 6.74, and 30% Freon to the PCM Chamber is 6.62. The length of time the PCM freezes at different flow variations, the more Freon flows into the PCM Chamber the less time it takes for the PCM freezing process, as with 50% PCM flow data is 8343.34 seconds or 2 hours 31 minutes, 40% PCM flow is 8668.30 seconds or 2 hours 40 minutes, and for 30% PCM flow is 9017.99 seconds or 2 hours 50 minutes. In conventional air conditioners, the length of the process of cooling the room with a set temperatur of 20 oC in 5 minutes obtained the average temperatur in the room is 23 oC while in Hybrid AC the length of the process of cooling the room with a set temperatur of 20 oC in 5 minutes is 22.57 oC. The time needed to cool conventional air conditioners and hybrid air conditioners is not so far away, but Conventional ACs can cool faster when compared to Hybrid AC
Item Type: | Thesis (Other) |
---|---|
Uncontrolled Keywords: | Perfoma, COP, Suhu, Velocity, Energi; Perfomance, COP, Temperatur, Velocity, Energi |
Subjects: | T Technology > TJ Mechanical engineering and machinery > TJ263 Heat exchangers |
Divisions: | Faculty of Marine Technology (MARTECH) > Marine Engineering > 36202-(S1) Undergraduate Thesis |
Depositing User: | Fhadila Putri Aldiva |
Date Deposited: | 28 Aug 2023 01:31 |
Last Modified: | 28 Aug 2023 01:40 |
URI: | http://repository.its.ac.id/id/eprint/102168 |