Evaluasi Dosis Radiasi dan Kualitas Citra pada Pemeriksaan CT Scan Kepala Anak Menggunakan Fantom Pediatri

Damayanti, Eka (2023) Evaluasi Dosis Radiasi dan Kualitas Citra pada Pemeriksaan CT Scan Kepala Anak Menggunakan Fantom Pediatri. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 01111940000013-Undergraduate_Thesis.pdf] Text
01111940000013-Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 September 2025.

Download (3MB) | Request a copy

Abstract

Fabrikasi fantom antropomorfik telah dilakukan berdasarkan referensi dari citra CT Scan pasien. Penelitian ini bertujuan untuk mengevaluasi kesetaraan jaringan fantom kepala pediatri dengan data pasien sesungguhnya dan untuk mengetahui dan menganalisis pengaruh metode Automatic Exposure Control (AEC) terhadap hasil dosis radiasi dan kualitas citra signal to noise ratio (SNR) fantom kepala pediatri pada pemeriksaan CT Scan kepala. Metode yang digunakan pada penelitian ini adalah fabrikasi fantom, pemindaian fantom dengan CT Scan, analisis nilai HU, analisis nilai keseragaman citra, analisis nilai SNR, analisis nilai CTDIvol dan DLP, dan analisis nilai dosis efektif dan risiko tumbuh kanker. Berdasarkan nilai HU dan uji keseragaman, fantom kepala yang telah dibuat sudah sesuai dengan jaringan asli pada pasien sesungguhnya untuk semua organ kecuali pada organ hidung yang memiliki selisih 11,74% jika dibandingkan dengan seluruh parameter dan 27,76% jika dibandingkan dengan parameter scanning yang paling mendekati yaitu 120 kV dan 300 mAs dengan 120 kV dengan 387 mAs. Pengaruh metode AEC terhadap dosis yang dihasilkan adalah jika berdasarkan dosis efektif, parameter 120 kV dan 500 mAs tidak sesuai dengan rekomendasi ICRP 102 yang melebihi nilai 1,0 2,8 mSv. Sedangkan berdasarkan DLP, 5 parameter yang telah dilakukan bisa digunakan untuk rekomendasi scanning untuk anak-anak dengan nilai DLP yang tidak melebihi 1391 mGy.cm. Sedangkan untuk CTDIvol tertinggi sebesar 55,3 mGy terdapat pada parameter 120 kV dan 500 mAs dan sesuai dengan teori yang ada. Pengaruh metode AEC terhadap kualitas citra yang dihasilkan nilai SNR yang paling baik diantara tegangan dan arus lainnya dengan parameter 120 kV dan 200 mAs.
=====================================================================================================================================
Anthropomorphic phantom fabrication has been carried out based on references from the patient's CT scan image. This study aims to evaluate the equivalence of pediatric head phantom tissue with actual patient data and to determine and analyze the effect of the Automatic Exposure Control (AEC) method on the results of radiation dose and image quality of the signal-to-noise ratio (SNR) of pediatric head phantoms on head CT scans. The methods used in this study were phantom fabrication, phantom scanning with CT Scan, analysis of HU values, analysis of image uniformity values, analysis of SNR values, analysis of CTDIvol and DLP values, and analysis of effective dose values and the risk of developing cancer. Based on the HU value and uniformity test, the head phantom that has been made is in accordance with the original tissue in the actual patient for all organs except for the nose organ, which has a difference of 11.74% when compared to all parameters and 27.76% when compared to the scanning parameters used, the closest is 120 kV and 300 mAs with 120 kV with 387 mAs. The effect of the AEC method on the resulting dose is that based on the effective dose, the parameters 120 kV and 500 mAs are not in accordance with the ICRP 102 recommendation, which exceeds the value of 1.0 2.8 mSv. Meanwhile, based on DLP, the 5 parameters that have been carried out can be used for scanning recommendations for children with DLP values that do not exceed 1391 mGy.cm. Meanwhile, the highest CTDIvol of 55.3 mGy is found in the parameters 120 kV and 500 mAs which are in accordance with existing theory. In addition, the effect of the AEC method on the resulting image quality produced the best SNR values among other voltage and current with parameters 120 kV and 200 mAs.

Item Type: Thesis (Other)
Uncontrolled Keywords: Automatic Exposure Control (AEC), Pediatric Anthropomorphic Pediatric, Signal to Noise Ratio (SNR); Automatic Exposure Control (AEC), Fantom Antropomorfik Pediatri, Signal to Noise Ratio (SNR).
Subjects: Q Science
Q Science > QC Physics
R Medicine > R Medicine (General)
R Medicine > RJ Pediatrics
Divisions: Faculty of Science and Data Analytics (SCIENTICS) > Physics > 45201-(S1) Undergraduate Thesis
Depositing User: Eka Damayanti
Date Deposited: 31 Aug 2023 04:29
Last Modified: 31 Aug 2023 04:29
URI: http://repository.its.ac.id/id/eprint/102713