Evaluasi Dosis dan Kualitas Citra pada Pemeriksaan CT Scan Toraks Anak Usia 12 Tahun Menggunakan Fantom Antropomorfik Pediatri

Rahmah, Alvina Maulidah (2023) Evaluasi Dosis dan Kualitas Citra pada Pemeriksaan CT Scan Toraks Anak Usia 12 Tahun Menggunakan Fantom Antropomorfik Pediatri. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 01111940000006-Undergraduate_Thesis.pdf] Text
01111940000006-Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 September 2025.

Download (3MB) | Request a copy

Abstract

Penelitian ini dilakukan dengan tujuan untuk mengevaluasi kesetaraan fantom antropomorfik pediatri dengan jaringan sesungguhnya pada pemeriksaan Computed Tomography (CT) Scan toraks, mengevaluasi pengaruh mode manual dan Automatic Exposure Control (AEC) terhadap dosis pada fantom antropomorfik pediatri usia 12 tahun, dan mengevaluasi pengaruh mode manual dan AEC terhadap kualitas citra (noise, signal to noise ratio) pada fantom antropomorfik pediatri usia 12 tahun. Penelitian ini menggunakan Multi Slice Computed Tomography (MSCT) Scan 128 slice untuk akuisisi data dosis dan kualitas citra. Pada mode manual tegangan yang digunakan adalah 90, 100, dan 120 kV dan arus tetap 200 mili ampere second (mAs) serta tegangan 120 kV dengan arus 78, 199, dan 298 mAs, pada mode AEC digunakan nilai tegangan 120 kV dan terjadi penyesuaian arus tabung. Berdasarkan nilai HU, fantom antropomorfik toraks pediatri yang dibuat peneliti sudah sesuai dengan jaringan sesungguhnya untuk semua organ kecuali pada jantung, tulang rusuk, dan sumsum tulang belakang karena nilainya mempunyai perbedaan dengan nilai referensi pasien. Pengaruh mode manual dan AEC terhadap dosis yaitu semakin besar nilai tegangan dan arus tabung, semakin meningkat pula nilai dosis yang dihasilkan. Mode AEC menghasilkan nilai dosis yang lebih rendah yaitu 10,7 mGy dibandingkan dengan mode manual yaitu 14,2 mGy. Pengaruh mode manual dan AEC terhadap kualitas citra adalah semakin besar nilai tegangan dan arus tabung, semakin rendah kualitas citranya. Mode AEC menghasilkan nilai SNR yang rendah yaitu -25,9 dibandingkan dengan mode manual sebesar -24,7.
====================================================================================================================================
This study was conducted with the aim of evaluating the equivalence of pediatric anthropomorphic phantom with real tissue on a thorax Computed Tomography (CT) Scan examination, evaluating the effect of manual mode and Automatic Exposure Control (AEC) on dose in pediatric anthropomorphic phantom aged 12 years, and evaluating the effect of manual mode and AEC on image quality (noise, signal to noise ratio) in a 12 years old pediatric anthropomorphic phantom. This research uses Multi Slice Computed Tomography (MSCT) Scan 128 slices for dose data acquisition and image quality. In manual mode the voltage used is 90, 100, and 120 kV and a fixed current of 200 milliamperes second (mAs) and a voltage of 120 kV with a current of 78, 199, and 298 mAs, in AEC mode a voltage value of 120 kV is used and there is a current adjustment tube. Based on the HU value, the pediatric thoracic anthropomorphic phantom made by the researchers corresponds to the real tissue for all organs except for the heart, ribs, and spinal cord because the values differ from the patient's reference values. The effect of manual mode and AEC on the dose is that the greater the value of the tube voltage and current, the higher the resulting dose value. The AEC mode produces a lower dose value of 10.7 mGy compared to the manual mode which is 14.2 mGy. The effect of manual mode and AEC on image quality is that the greater the value of the tube voltage and current, the lower the image quality. The AEC mode produces a low SNR value of -25.9 compared to the manual mode of -24.7.

Item Type: Thesis (Other)
Uncontrolled Keywords: AEC, Computed Tomography, Fantom Antropomorfik Pediatri; AEC, Computed Tomography, Pediatric Anthropomorphic Phantom
Subjects: Q Science > Q Science (General)
Q Science > QC Physics
R Medicine > R Medicine (General)
R Medicine > RJ Pediatrics
Divisions: Faculty of Science and Data Analytics (SCIENTICS) > Physics > 45201-(S1) Undergraduate Thesis
Depositing User: Alvina Maulidah Rahmah
Date Deposited: 11 Sep 2023 01:10
Last Modified: 11 Sep 2023 01:10
URI: http://repository.its.ac.id/id/eprint/102808

Actions (login required)

View Item View Item