Evaluasi Indikasi Kontaminasi Radiasi dan Pemodelan Hamburan Radiasi Pesawat Sinar-X CT Scan terhadap Paparan Pendamping Pasien di Ruang Pengendalian CT Scan

Latif, Muh Rizkiawan (2023) Evaluasi Indikasi Kontaminasi Radiasi dan Pemodelan Hamburan Radiasi Pesawat Sinar-X CT Scan terhadap Paparan Pendamping Pasien di Ruang Pengendalian CT Scan. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 01111840000104-Undergraduate_Thesis.pdf] Text
01111840000104-Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 October 2025.

Download (9MB) | Request a copy

Abstract

Proteksi radiasi merupakan permasalahan yang sangat vital dalam operasional instalasi radiologi di rumah sakit. Dalam penerapannya, BAPETEN memandatkan fisikawan medik sebagai supervisi utama dalam menjalankan tugas sebagai petugas proteksi radiasi. Oleh sebab itu, penelitian ini dilakukan dengan maksud dan tujuan untuk membantu fisikawan medik rumah sakit X dalam peninjauan kembali pembatasan dosis di rumah sakit. Adapun fokus utama dalam penelitian ini yakni menetapkan nilai background radiation dan memodelkan hamburan radiasi pesawat sinar-X CT scan di dalam ruang pengendalian agar pertimbangan paparan medik yang diterima pendamping/keluarga pasien saat menemani pasien (balita-anak/lansia) dapat diminimalisir. Namun, seiring berjalannya penelitian, terdapat sebuah temuan kenaikan background radiation yang cukup signifikan di dalam ruang pengendalian sehingga hal tersebut dapat diindikasikan sebagai dugaan kontaminasi radiasi. Alat dan bahan dalam penelitian ini, yakni instalasi pesawat sinar-X CT scan (termasuk shielding tembok), survey meter, rol meter, dan laptop. Dalam proses pengolahan data, penelitian ini menggunakan metode analisis numerik mulai dari menyajikan data sampai dengan menarik kesimpulan, bahkan memprediksi sebuah kemungkinan-kemungkinan dengan pemodelan. Hasil yang didapat pada penelitian ini yakni nilai rata-rata background radiation berkisar antara 0,0908–0,1227 µSv/h; prediksi indikasi kontaminasi radiasi pada regresi polinomial sampai orde-4; pemodelan hamburan radiasi pesawat sinar-X CT scan dengan kontur dan simulasi partikel; dan nilai sensitivitas absorpsi shielding pada rentang 0,105–0,110 µSv/h.
=================================================================================================================================
Radiation protection is a very vital issue in the operation of radiology installations in hospitals. In practice, BAPETEN mandates medical physicists as the main supervisor in carrying out their duties as radiation protection officers. Therefore, this research was conducted with the intent and purpose of assisting medical physicists at X hospital in reviewing dose restrictions at the hospital. The main focus in this study is to determine the background radiation value and model the radiation scattering of CT scan X-rays in the control room so that medical exposure considerations received by the patient's companion/family when accompanying the patient (pediatric/elderly) can be minimized. However, as the research progresses, there is a finding of a significant increase in background radiation in the control room so that this can be indicated as a suspected radiation contamination. The tools and materials in this study are the installation of a CT scan X-ray machine (including wall shields), survey meters, meter rolls, and laptops. In the data processing process, this study uses numerical analysis methods starting from presenting data to drawing conclusions, even predicting possibilities with modeling. The results obtained in this study are the average value of background radiation ranging from 0.0908–0.1227 µSv/h; prediction of indications of radiation contamination in polynomial regression up to order-4; CT scan X-ray radiation scattering modeling with contour and particle simulation; and absorption shielding sensitivity values in the range of 0.105–0.110 µSv/h.

Item Type: Thesis (Other)
Uncontrolled Keywords: Indikasi Kontaminasi Radiasi, Metode Analisis Numerik, Pemodelan Hamburan Radiasi, Pesawat Sinar-X CT Scan, Survey Meter
Subjects: Q Science > QC Physics
Divisions: Faculty of Mathematics and Science > Physics > 45201-(S1) Undergraduate Thesis
Depositing User: Muh Rizkiawan Latif
Date Deposited: 08 Aug 2023 04:29
Last Modified: 08 Aug 2023 04:31
URI: http://repository.its.ac.id/id/eprint/103170

Actions (login required)

View Item View Item