Studi Kasus Pipe Support Hanger Pada Pipa Fire Hydrant Mengunakan Material Ss400 Berdasarkan Beban Yang Bekerja

Prasetyo, Dhimas Bagus (2023) Studi Kasus Pipe Support Hanger Pada Pipa Fire Hydrant Mengunakan Material Ss400 Berdasarkan Beban Yang Bekerja. Diploma thesis, Insitut Teknologi Sepuluh Nopember.

[thumbnail of 10211910000046_Undergraduate_Thesis.pdf] Text
10211910000046_Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 October 2025.

Download (2MB) | Request a copy

Abstract

Perancangan sistem perpipaan yang baik dan aman sangat dibutuhkan untuk menjamin kelangsungan proses produksi serta menjamin keamanan. Pada tanggal 15 Juli 2015 saluran pipa di fasilitas pasir minyak Long Lake di Alberta utara. Ketika salah satu sambungan siku pipa pecah, membocorkan sekitar 31.500 barel emulsi minyak. Tumpahan menutupi sekitar 16.000 meter persegi tetapi sebagian besar berada di dalam jalur pipa yang tepat. Oleh karena itu, perlu dilakukan perhitungan analisis tegangan untuk mengetahui berapa besar tegangan yang dapat ditanggung oleh pipa dan peralatan pendukungnya tanpa terjadi kegagalan. Untuk mengatasi besarnya tegangan yang terjadi akibat pembebanan maka diperlukan analisis. Pada tugas akhir ini akan dianalisis beban yang bekerja pada pipe Support pipa fire hydrant. Penelitian ini dilakukan pada studi kasus hanger support pada sistem pepipaan fire hydrant. Data dikumpulkan dalam bentuk pertanyaan yang ditanyakan kepada enginner lapangan mengenai spesifikasi sistem perpipaan fire hydrant dan komponen hanger support. dengan menghitung allowable span (jarak maksimum support) berdasarkan batas maksimum stress dan batas defleksi dan dilanjutkan mengitung beban yang bekerja pada hanger support di setiap komponen Dilanjutkan olah data kuantitatif dengan perhitungan teoritis dan simulasi pembebanan sesuai kapasitas yang dibutuhkan menggunakan perangkat lunak untuk mendapatkan data mengenai beban yang berkerja pada komponen hanger support. Selanjutnya dilakukan verifikasi untuk melihat selisih antara perhitungan secara teoritis dan simulasi. Pada hasil allowable span ( jarak maksimum support) berdasarkankan batas stress maksimum dan batas defleksi dan diambil paling pendek sebesar 3,64 untuk pipa 4 inch dan 2,68 untuk pipa 2,5 inch..Agar dapat mencapai parameter keamanan pemasangan pipe support sendiri tidak diletakkan pada jarak maksimum allowable span, hal ini sebagai safety factor agar tidak terjadi over stress walaupun sudah masuk dalam jarak allowablenya, dalam hal ini Pemasangan pipe support untuk pipa 4 inch dan 2,5inch menggunakan jarak antar support sejauh 2,2 meter. Dengan spesifikasi desain Fire Hydrant tersebut Hasil dari perhitungan simulasi dari hasil dengan spesifikasi desain Hanger Support tersebut didapatkan perhitungan beban yang bekerja pada komponen Bracket L didapatkan nilai tegangan maksimum von mises sebesar 5,678 MPa material SS 400, Hanger Rod sebesar 13,917 MPa material SS 400, Berdasarkan data tegangan izin material SS 400 sebesar 57,14 MPa dengan batas nilai safety factor sebesar 3.5. Untuk hasil selisih hasil simulai dan teoritis dengan spesifikasi desain Hanger Support tersebut pada komponen Bracket L 0,047 dengan presentase 0,65%, Hanger Rod sebesar 0,16 dengan presentase 8,33%. =================================================================================================================================
The design of a good and safe piping system is needed to guarantee the recovery of the production process and ensure safety. On July 15, 2015 a pipeline at the Long Lake oil sands facility in northern Alberta. When one of the pipe elbow joints ruptured, it leaked approximately 31,500 barrels of oil emulsion. The spill covered about 16,000 square meters but most of it was within the proper pipeline. Therefore, it is necessary to do a stress analysis calculation to find out how much stress can be borne by the pipe and its supporting equipment without failure. To overcome the amount of stress that occurs due to loading, analysis is needed. In this final project will be analyzed the load acting on the fire hydrant pipe support pipe.This research was conducted on a hanger support case study on a fire hydrant piping system. Data is collected in the form of questions asked to field engineers regarding the specifications of the fire hydrant piping system and hanger support components. by calculating the allowable span (maximum support distance) based on the maximum stress limit and deflection limit and continuing to calculate the load acting on the hanger support in each component. acting on the hanger support component. Furthermore, verification is carried out to see the difference between theoretical calculations and simulations. he results of the allowable span (maximum support distance) are based on the maximum stress limit and deflection limit and are taken as the shortest of 3.64 for a 4 inch pipe and 2.68 for a 2.5 inch pipe. In order to achieve safety parameters, the pipe support installation itself is not placed at the maximum allowable span distance, this is a safety factor so that over stress does not occur even though it is within the allowable distance, in this case the installation of pipe supports for 4 inch and 2.5 inch pipes uses a distance between supports of 2.2 meters. With these Fire Hydrant design specifications, the results of the simulation calculations from the results with the Hanger Support design specifications obtained from the calculation of the load acting on the L-Bracket component obtained the maximum von Mises stress value of 5.678 MPa for SS 400 material, for Hanger Rod at 13.917 MPa for SS 400 material, based on Permissible stress data for SS 400 material is 57.14 MPa with a safety factor limit of 3.5. For the results of the difference between the simulation and theoretical results with the Hanger Support design specifications for the L Bracket component of 0.047 with a percentage of 0.65%, Hanger Rod of 0.16 with a percentage of 8.33%

Item Type: Thesis (Diploma)
Uncontrolled Keywords: sistem perpipaan,allowable span, Beban
Subjects: Q Science
Q Science > Q Science (General)
Divisions: Faculty of Vocational > Mechanical Industrial Engineering
Depositing User: DIMAS Bagus Prasetyo
Date Deposited: 27 Nov 2023 08:29
Last Modified: 27 Nov 2023 08:29
URI: http://repository.its.ac.id/id/eprint/103697

Actions (login required)

View Item View Item