Analisis Dosis Efektif Dan Dosis Radiasi Organ Mata Pasien Pemeriksaan Ct Kepala Menggunakan Indosect Dan Multimeter Raysafe X2

Jayandini, Oryza Fortunesty Dita (2023) Analisis Dosis Efektif Dan Dosis Radiasi Organ Mata Pasien Pemeriksaan Ct Kepala Menggunakan Indosect Dan Multimeter Raysafe X2. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 01111940000025-Undergraduate_Thesis.pdf] Text
01111940000025-Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 October 2025.

Download (2MB) | Request a copy

Abstract

Dosis efektif adalah ukuran radiasi yang mencerminkan jumlah energi radiasi yang diserap oleh seluruh tubuh atau bagian tubuh tertentu dan potensi kerusakan biologis yang terkait. Sedangkan dosis organ mengacu pada jumlah radiasi yang diterima oleh organ-organ tertentu dalam tubuh. Dosis efektif dan dosis organ memiliki hubungan yang erat karena dosis organ merupakan komponen yang digunakan untuk menghitung dosis efektif. Penelitian tugas akhir ini bertujuan untuk menganalisis nilai dosis efektif dari CT Scan kepala berdasarkan usia dan jenis kelamin pada Instalasi Radiologi RSUD Simpang Lima Gumul Kediri, memverifikasi nilai dosis efektif CT Scan kepala sesuai dengan aturan komisi Internasional American Association of Physicists in Medicine (AAPM), membandingkan dan menganalisis nilai dosis radiasi pada mata berdasarkan tegangan dan arus tabung menggunakan Multimeter Raysafe X2 dan Software IndoseCT, dan memverifikasi nilai dosis radiasi pada mata nilai ambang dosis yang ditetapkan oleh Badan Pengawas Tenaga Nuklir (Bapeten). Metode yang digunakan dalam penelitian ini yaitu dengan mengumpulkan sampel pasien CT Scan kepala RSUD Simpang Lima Gumul Kediri dengan mengelompokkan usia menjadi enam kategori kemudian dianalisa data dosis efektif dan dosis organ mata dengan menggunakan software IndoseCT. Kemudian dilakukan uji fantom kepala dengan variasi parameter tegangan sebesar 90 kV dengan arus tabung 230 mAs dan tegangan sebesar 120 kV dengan arus tabung 329 mAs untuk membandingkan nilai dosis organ pada mata menggunakan perhitungan software IndoseCT dan multimeter RaySafe X2. Setelah diperoleh data kemudian data dianalisis dan diverifikasi menggunakan ketentuan lembaga berwenang yaitu BAPETEN dan AAPM. Dari hasil analisis yang dilakukan nilai dosis efektif dipengaruhi oleh besarnya nilai DLP (mGy). Nilai dosis radiasi mata dipengaruhi oleh parameter yang digunakan yaitu tegangan dan arus tabung terbukti dengan hasil uji korelasi yang telah dilakukan yaitu antara tegangan dan dosis radiasi mata nilai sig. sebesar 0,00 < 0,05 dan nilai korelasi sebesar 0,540 sedangkan antara arus tabung dan dosis radiasi mata sebesar 0,00 < 0,05 dan nilai korelasi sebesar 0,897. Uji pengukuran dosis radiasi pada mata dengan fantom kepala menunjukkan bahwa dengan menggunakan software IndoseCT nilai dosis radiasi yang diterima mata lebih besar dibandingkan multimeter RaySafe X2. Kemudian setelah dianalisis nilai dosis efektif dan dosis organ pada mata tidak ada yang melebihi ketentuan BAPETEN dan AAPM.
================================================================================================================================
The effective dose measures the radiation that reflects the amount of radiant energy absorbed by the whole body or a specific body part and the associated biological damage potential. Meanwhile, organ dose refers to the amount of radiation received by specific organs in the body. Effective dose and organ dose have a close relationship because organ dose is the component used to calculate the effective dose. This final project research aims to analyze the effective dose value of head CT scan based on age and gender in the Radiology Installation of Simpang Lima Gumul Hospital Kediri, verify the effective dose value of head CT scan in accordance with the rules of the International Commission of the American Association of Physicists in Medicine (AAPM), compare and analyze the value of radiation dose to the eye based on tube voltage and current using the Multimeter Raysafe X2 and IndoseCT Software, and verify the value of the radiation dose to the eye the dose threshold value set by the Nuclear Energy Supervisory Agency (Bapeten). The method used in this study was to collect a sample of CT Scan patients at Simpang Lima Gumul Hospital, Kediri, by grouping their ages into six categories, then analyzing the effective dose data and eye organ doses using the IndoseCT software. Then a head phantom test was carried out with a variation of the parameter voltage of 90 kV with a tube current of 230 mAs and a voltage of 120 kV with a tube current of 329 mAs to compare the dose values of organs in the eye using the calculation software IndoseCT and multimeter RaySafe X2. After obtaining the data, the data was analyzed and verified using the provisions of the authorized institutions, namely BAPETEN and AAPM. From the results of the analysis carried out, the value of the effective dose is influenced by the value of the DLP (mGy). The value of eye radiation dose is influenced by the parameters used, namely the voltage and current of the tube as evidenced by the results of the correlation test that has been carried out, namely between voltage and eye radiation dose the sig value. of 0,00 < 0,05 and a correlation value of 0,540 while between tube current and eye radiation dose of 0,00 < 0,05 and a correlation value of 0,897. The test for measuring radiation dose to the eye with a head phantom shows that by using the IndoseCT software, the value of the radiation dose received by the eye is greater than the multimeter RaySafe X2. Then after analyzing the value of the effective dose and organ dose in the eye, nothing exceeds the provisions of BAPETEN and AAPM.

Item Type: Thesis (Other)
Uncontrolled Keywords: CT-Scan, Dosis Efektif, Dosis Organ, IndoseCT, Multimeter RaysafeX2, Effective Dose, Organ Dose
Subjects: Q Science > QC Physics
Divisions: Faculty of Science and Data Analytics (SCIENTICS) > Physics > 45201-(S1) Undergraduate Thesis
Depositing User: Oryza Fortunesty Dita Jayandini
Date Deposited: 09 Aug 2023 02:29
Last Modified: 09 Aug 2023 02:29
URI: http://repository.its.ac.id/id/eprint/103764

Actions (login required)

View Item View Item