Modifikasi Elektroda Karbon Untuk Penentuan Ion Klorida (Cl-) Menggunakan Metode Voltammetri

Mustakim, Fahriyan (2023) Modifikasi Elektroda Karbon Untuk Penentuan Ion Klorida (Cl-) Menggunakan Metode Voltammetri. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 01211940000035_Undergraduate_Thesis.pdf] Text
01211940000035_Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 October 2025.

Download (2MB) | Request a copy

Abstract

Dalam penentuan kualitas air, diagnosis penyakit, dan pemantauan proses industri, analisis ion klorida (Cl-) yang akurat dan cepat sangat penting. Salah satu metode yang sering digunakan untuk menentukan ion klorida adalah metode elektrokimia, terutama voltammetri. Sensitivitas dan selektivitas metode voltammetri dipengaruhi oleh jenis dan komposisi elektroda kerja yang digunakan. Oleh karena itu, dilakukan pengembangan modifikasi pada elektroda kerja untuk mencapai hasil yang lebih akurat. Modifikasi elektroda CA-PPy dipilih sebagai pendekatan yang menjanjikan untuk meningkatkan sensitivitas dan respons elektroda. CA-PPy merupakan singkatan dari Karbon Aerogel-Polipirol, yang merupakan jenis modifikasi elektroda yang terdiri dari struktur karbon aerogel dengan lapisan polipirol. Elektroda CA disintesis menggunakan metode sol-gel dengan resorsinol dan formaldehid sebagai prekursor, kemudian dilapisi dengan polipirol melalui metode siklik voltammetri. Sifat elektrokimia dari elektroda CA-PPy dianalisis menggunakan metode CV (Cyclic Voltammetry) dan DPV (Differential Pulse Voltammetry). Uji CV dalam larutan K3[Fe(CN)6] menunjukkan bahwa elektroda modifikasi CA-PPy memiliki arus puncak oksidasi terbesar, yaitu 0,0266 mA, yang menunjukkan aktivitas elektrokimia yang tinggi. Reversibilitas elektroda juga meningkat setelah dilakukan modifikasi, ditandai dengan peningkatan perbandingan Ipa: ipc elektroda antara karbon, C-PPy, dan CA-PPy, yaitu 0,6754; 0,8; 0,8778. Hasil uji DPV menunjukkan bahwa elektroda CA-PPy memiliki sensitivitas yang baik terhadap larutan klorida. Respons elektroda meningkat secara linier seiring dengan peningkatan konsentrasi klorida yang diuji. Hal ini juga dibuktikan oleh peningkatan nilai gradien dari elektroda karbon, C-PPy, dan CA-PPy sebelum dan sesudah dilakukan modifikasi, yaitu 0,071; 0,3238; 0,3335.
=================================================================================================================================
Accurate and rapid analysis of chloride ions (Cl-) is highly important in determining water quality, diagnosing diseases, and monitoring industrial processes. One commonly used method for determining chloride ions is electrochemical analysis, particularly voltammetry. The sensitivity and selectivity of the voltammetry method are influenced by the type and composition of the working electrode used. Therefore, modifications to the working electrode are developed to achieve more accurate results. The CA-PPy electrode modification is chosen as a promising approach to enhance sensitivity and electrode response. CA-PPy stands for Carbon Aerogel-Polypyrrole, which is a modified type of electrode consisting of a carbon aerogel structure with a polypyrrole coating. The CA electrode is synthesized using a sol-gel method with resorcinol and formaldehyde as precursors, and then coated with polypyrrole through cyclic voltammetry. The electrochemical properties of the CA-PPy electrode are analyzed using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods. CV testing in a K3[Fe(CN)6] solution demonstrates that the modified CA-PPy electrode exhibits the highest peak oxidation current, specifically 0.0266 mA, indicating high electrochemical activity. The electrode's reversibility also improves after modification, as evidenced by the increased Ipa:ipc ratio of the electrode between carbon, C-PPy, and CA-PPy, namely 0.6754, 0.8, and 0.8778. DPV results indicate that the CA-PPy electrode has good sensitivity to chloride solutions. The electrode response increases linearly with the tested chloride concentration. This is further supported by the increased slope values of the carbon, C-PPy, and CA-PPy electrodes before and after modification, which are 0.071, 0.3238, and 0.3335, respectively.

Item Type: Thesis (Other)
Uncontrolled Keywords: CA-PPy, Chloride, CV, DPV, Sensitivity,CA-PPy, CV, DPV, Klorida, Sensitifitas.
Subjects: Q Science > QD Chemistry > QD75.2 Chemistry, Analytic
Divisions: Faculty of Science and Data Analytics (SCIENTICS) > Chemistry > 47201-(S1) Undergraduate Thesis
Depositing User: Fahriyan Mustakim
Date Deposited: 08 Aug 2023 01:41
Last Modified: 08 Aug 2023 01:41
URI: http://repository.its.ac.id/id/eprint/103778

Actions (login required)

View Item View Item