Sa'diyah, Siti Aminatus (2023) Analisis Kuantitatif Estimasi Dosis Efektif CT Scan Head pada Pasien Tumor Otak di RSUD Karsa Husada Batu. Other thesis, Institut Teknologi Sepuluh Nopember.
Text
01111940000007-Undergraduate_Thesis.pdf - Accepted Version Restricted to Repository staff only until 1 October 2025. Download (3MB) | Request a copy |
Abstract
Telah dilakukan penelitian yang berjudul “Analisis Kuantitatif Estimasi Dosis Efektif CT Scan Head pada Pasien Tumor Otak di RSUD Karsa Husada Batu” yang bertujuan untuk menganalisis hasil estimasi dosis efektif yang diterima pasien tumor otak pada pemeriksaan CT Scan head di RSUD Karsa Husada Batu serta membandingkan dosis efektif yang diterima pasien tumor otak dengan dosis efektif yang ditetapkan oleh BAPETEN. Penelitian ini dilakukan dengan cara observasi langsung terhadap objek yang diamati, dalam penelitian ini adalah alat CT Scan Hitachi tipe Scenaria / CT-WS-19A dengan nomor seri tabung 55496P6. Setelah proses scanning dilakukan maka pada layar komputer akan muncul nilai keluaran CTDIvol dan DLP dari pesawat CT Scan. Data yang didapatkan berupa 6 data rekam medis dengan format DICOM yang kemudian diolah untuk mendapatkan nilai dosis efektifnya. Dosis efektif merupakan perkalian antara nilai DLP dengan faktor bobot jaringan. Dari hasil penelitian menunjukkan dosis efektif rerata perhitungan dengan IndoseCT berturut-turut adalah 0,80 mSv dan 1,01 mSv pada pemeriksaan CT Scan non kontras. Dengan nilai maksimum dan minimalnya berturut-turut adalah 1,04 mSv dan 1,34 mSv serta 0,64 mSv dan 0,77 mSv. Diketahui bahwa nilai batas dosis efektif yang ditetapkan oleh BAPETEN sebesar 2,94 mSv untuk kepala, dengan membandingkan nilai rerata yang diperoleh pada perhitungan yaitu 1,01 mSv maka dosis yang diterima masih di bawah ambang batas dosis. Sehingga pesawat CT Scan Hitachi yang berada di Instalasi Radiologi RSUD Karsa Husada Batu masih layak dan aman digunakan untuk pemeriksaan CT Scan bagian kepala.
=================================================================================================================================
A research entitled "Quantitative Analysis of Effective Dose Estimation of CT Scan Head in Brain Tumor Patients at RSUD Karsa Husada Batu" has been conducted, which aims to analyze the results of effective dose estimation received by brain tumor patients on CT Scan head examination at RSUD Karsa Husada Batu and compare the effective dose received by brain tumor patients with the effective dose determined by BAPETEN. This research is conducted by direct observation of the object observed, in this research is Hitachi CT Scan tool type Scenaria / CT-WS-19A with tube serial number 55496P6. After the scanning process is done, the CTDIvol and DLP output values from the CT Scan aircraft will appear on the computer screen. The data obtained is in the form of 6 medical record data in DICOM format which is then processed to obtain the effective dose value. The effective dose is the multiplication between the DLP value and the tissue weighting factor. The results showed that the average effective dose calculated with IndoseCT was 0.80 mSv and 1.01 mSv in non-contrast CT Scan examination, respectively. The maximum and minimum values were 1.04 mSv and 1.34 mSv and 0.64 mSv and 0.77 mSv, respectively. It is known that the effective dose limit value set by BAPETEN is 2.94 mSv for the head, by comparing the average value obtained in the calculation which is 1.01 mSv, the dose received is still below the dose threshold. So that the Hitachi CT Scan aircraft in the installation of RSUD Karsa Husada Batu is still feasible and safe to use for CT Scan examination of the head.
Item Type: | Thesis (Other) |
---|---|
Uncontrolled Keywords: | DLP, Dosis Efektif, Tumor Otak, Brain Tumor, Effective Dose. |
Subjects: | Q Science > QC Physics R Medicine > RC Internal medicine > RC78 Diagnosis, Radioscopic--Examinations, questions, etc. |
Divisions: | Faculty of Science and Data Analytics (SCIENTICS) > Physics > 45201-(S1) Undergraduate Thesis |
Depositing User: | Siti Aminatus Sa'diyah |
Date Deposited: | 08 Aug 2023 02:40 |
Last Modified: | 08 Aug 2023 02:40 |
URI: | http://repository.its.ac.id/id/eprint/103972 |
Actions (login required)
View Item |