Abstract

Unit Pelayanan Zona 2 merupakan salah satu Zona yang terletak di bagian timur Kota Surabaya Dari data PDAM Surya Sembada Kota Surabaya pada tahun 2022 tingkat tekanan air di Zona 2 tidak sesuai dengan Peraturan Pemerintah PU No.18 Tahun 2007 yaitu masih dibawah 0.5 m. kurangnya tekanan air tersebut disebabkan tidak bisanya PDAM menyesuaikan dengan pertumbuhan pelanggan sehingga menyebabkan tekanan di wilayah servis area rendah. Dilakukannya evaluasi di Zona 2 agar mampu memenuhi kebutuhan air bersih secara merata dengan kualitas, kuantitas dan kontinuitas serta tekanan air yang mencukupi. Analisis evaluasi ang dilakukan meliputi analisis teknis. Analisis teknis dilakukan berdasarkan data yang didapatkan di lapangan dan analisis simulasi sistem distribusi dilakukan dengan program Watergems. Hasil evaluasi didapatkan hasil bahwa tekanan air di beberapa wilayah memiliki tekanan yang kecil dibawah standar perencanaan yaitu 0.3 atm dan beberapa wilayah yang mengalami kecepatan aliran yang rendah dengan nilai dibawah standar perencanaan 0.5 m/s. upaya perbaikan yang dilakukan adalah dengan penyesuaian diameter pipa atau penggantian pipa
=================================================================================================================================
Unit Service Zone 2 is one of the zones located in the eastern part of Surabaya City. Based on data from PDAM Surya Sembada Kota Surabaya in 2022, the water pressure level in Zone 2 does not comply with Government Regulation PU No. 18 of 2007, as it is still below 0.5 m. The lack of water pressure is due to PDAM's inability to adjust to the growing number of customers, resulting in low pressure in the service area. An evaluation was conducted in Zone 2 to ensure the even distribution of clean water with sufficient quality, quantity, continuity, and adequate water pressure. The evaluation analysis includes technical analysis, which was carried out based on field data and simulation analysis of the distribution system using the Watergems program. The evaluation results indicated that some areas had water pressure below the planning standard of 0.3 atm, and some areas experienced low flow velocity with values below the planning standard of 0.5 m/s. Efforts to improve the situation involve adjusting pipe diameters or replacing pipes..

Item Type: Thesis (Other)
Uncontrolled Keywords: Watergems, Zona 2, PDAM, Evaluasi Jaringan Distribusi
Subjects: T Technology > TD Environmental technology. Sanitary engineering > TD481 Water distribution systems