Desain Alat Bantu Pengujian Ultrasonik Immersion Menggunakan Teknik Phased Array Untuk Pengujian Restak Pada Baut Komponen Kapal

Nagoro, Adhika Reshworo Sakstyo (2023) Desain Alat Bantu Pengujian Ultrasonik Immersion Menggunakan Teknik Phased Array Untuk Pengujian Restak Pada Baut Komponen Kapal. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 04111740000074-Undergraduate_Thesis.pdf] Text
04111740000074-Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 October 2025.

Download (6MB) | Request a copy

Abstract

Baut merupakan suatu material yang menghubungkan komponen-komponen kapal sehingga menjadi suatu rangkaian hingga akhirnya membentuk sebuah kapal. Namun, kerap kali ditemukan keretakan pada baut kapal sehingga hal ini dapat menganggu kinerja dari suatu kapal yang dapat menyebabkan kecelakaan kapal. Pada kondisi ini diperlukan suatu cara untuk mempermudah perawatan dan pemeriksaan baut kapal. Penelitian ini dibuat agar dapat membantu para engineer maupun inspector dalam menemukan keretakan pada baut kapal. Penelitian ini dilakukan menggunakan Immersion Phased Array Ultrasonic Test (PAUT) dengan mateial baut berbahan baja karbon dengan variasi ukuran diameter baut 8 mm, 10 mm, 12 mm, 14 mm, 16 mm, 18 mm, dan 20 mm. Baut yang diuji memiliki dua retak buatan pada bagian ulir dan pangkal baut. Kemudian probe yang digunakan adalah single probe berukuran 0.5 x 9 mm dan frekuensi 4.0 MHz. Tangki uji yang digunakan sebagai alat bantu dari penelitian ini terbuat dari akrilik dengan tebal 3 mm, dimensi ukuran tangki uji yang digunakan adalah 150 x 150 x 10 mm. Hasil dari penelitian ini menunjukan bahwa alat bantu uji ultrasonic testing immersion phased array ini dapat mendeteksi retak pada baut diameter 10 mm, 12 mm, 14 mm, 16 mm, 18 mm, dan 20 mm. Baut 8 mm tidak dapat terdeteksi karena diameter baut terlalu kecil sehingga gelombang yang dipancarkan tidak sempurna. Pengujian yang dilakukan membandingkan hasil yang didapatkan pada penelitian UT Immersion menggunakan probe normal dengan penelitian UT Immersion dengan metode phased array ini dapat disimpulkan bahwa hasil pada penelitian UT Immersion dengan metode phased array memiliki tingkat keakuratan yang lebih rendah dibandingkan penelitian UT Immersion dengan probe normal. Tingkat keakuratan dari pengujian yang telah dilakukan sebesar 92.25% pada crack 1, 96.23% pada crack 2, dan 96.1% pada backwall.
=====================================================================================================================================
Bolts are a material that connects the ship's components so that they become a series and finally form a ship. However, cracks are often found in the ship's bolts so that this can interfere with the performance of a ship which can cause a ship accident. In this condition, a method is needed to facilitate the maintenance and inspection of ship bolts. This research was made in order to help engineers and inspectors find cracks in ship bolts. This research was conducted with Phased Array Ultrasonic Test (PAUT) using bolts made of carbon steel with variations in bolt diameter sizes of 8 mm, 10 mm, 12 mm, 14 mm, 16 mm, 18 mm, and 20 mm. The tested bolt had two man-made cracks in the threaded portion and the base of the bolt. Then the probe used is a single probe measuring 0.5 x 9 mm and a frequency of 4.0 MHz. The test tank used as a tool for this research is made of acrylic with a thickness of 3 mm, the dimensions of the test tank size are 15 x 15 x 10 cm. The results of this study indicate that the ultrasonic testing immersion phased array test tool can detect cracks in bolts with diameters of 10 mm, 12 mm, 14 mm, 16 mm, 18 mm, and 20 mm. The 8 mm bolt cannot be detected because the bolt diameter is too small so that the waves emitted are not perfect. The test carried out compared the result obtained in the UT Immersion study using normal probes with the UT Immersion study using the phased array method, it can be concluded that the results in the UT Immersion study using the phased array method have a lower level of accuracy than the UT Immersion study with normal probes. The level of accuracy of the tests that have been carried out is 92.25% on crack 1, 96.23% on crack 2, and 98.61% on backwall.

Item Type: Thesis (Other)
Uncontrolled Keywords: Baut, Retak, Tangki Uji, UT Immersion, Phased Array; Bolts, Crack, Test Tank, UT Immersion, Phased Array
Subjects: V Naval Science > VM Naval architecture. Shipbuilding. Marine engineering
Divisions: Faculty of Marine Technology (MARTECH) > Naval Architecture and Shipbuilding Engineering > 36201-(S1) Undergraduate Thesis
Depositing User: Adhika Reshworo Sakstyo Nagoro
Date Deposited: 30 Aug 2023 00:57
Last Modified: 30 Aug 2023 04:10
URI: http://repository.its.ac.id/id/eprint/104893

Actions (login required)

View Item View Item