Kinasih, Titah Anggraeni Putri (2022) Analisis Tomografi 3D Pada Lapangan Panas Bumi Dengan Menggunakan Metode Local Earthquake Tomography. Other thesis, Institut Teknologi Sepuluh Nopember.
Text
03411840000019-Undergraduate_Thesis.pdf - Accepted Version Restricted to Repository staff only until 1 October 2024. Download (3MB) | Request a copy |
Abstract
Pada wilayah penelitian aktivitas microearthquake merupakan fenomena yang sering terjadi. Microearthquake pada wilayah penelitian sering terjadi akibat adanya aktivitas dari injeksi fluida yang bertekanan tinggi. Salah satu hal yang bisa dilakukan untuk menunjang hal tersebut dapat dilakukan dengan menggunakan bantuan tomografi seismik. Tomografi seismik menggambarkan pencitraan berdasarkan pengukuran data gelombang microearthquake yang tergambar pada suatu wilayah lapangan panas bumi. Maka dari itu tujuan dari penelitian ini adalah menyelidiki wilayah panas bumi berdasarkan struktur Vp, Vs, dan rasio Vp/Vs serta distribusi sebaran fluida melalui metode local earthquake tomography. Metode yang digunakan merupakan metode yang memanfaatkan data microearthquake yang banyak tersebar secara aktif pada suatu wilayah lapangan panas bumi. Data input yang digunakan dalam penelitian ini berupa data koordinat stasiun, waktu tiba gelombang P dan S, model kecepatan 1D, serta data dari lokasi hiposenter. Data tersebut akan diolah dengan menggunakan perangkat lunak SIMULPS12, lalu akan dilakukan pengujian menggunakan checkerboard resolution test sehingga didapatkan wilayah yang diinterpretasi berdasarkan anomali dari model kecepatan gelombang. Kemudian akan dilanjutkan dengan dilakukannya inversi yang nantinya akan menghasilkan model kecepatan gelombang P dan S. Setelah itu, akan dilakukan iterasi hingga ditemukan nilai RMS yang <1 dan apabila masih belum memenuhi standar akan dilakukan pengulangan pada tahapan inversinya. Berdasarkan peta Vp, Vs, dan Vp/Vs zona uap di bagian utara penelitian dengan elevasi -1.5 hingga 0 km dan semakin dalam menuju ke selatan dengan mengalami kenaikan hingga 1 km. Lalu pada bagian timur dengan lebar berkisar 2 km yang memiliki nilai Vp/Vs rendah dengan rentang nilai 1.6 – 1.70. Kemudian zona air berada tepat di bawah zona uap dengan nilai Vp/Vs yang tinggi diantara 1.78 – 1.85. Secara umum jenis fluida yang berada di lapangan penelitian ini merupakan jenis zona fluida uap yang digunakan pada wilayah produksi. Akan tetapi adanya aktivitas injeksi air meteorik di sekitar lokasi penelitian menyebabkan bawah lapisan fluida uap tersebut memiliki fluida cair di bawahnya, yang membentuk cyclic system. Model bawah permukaan dari wilayah penelitian terdiri dari dua lapisan yang utama, yaitu steam-saturated rock, dan water-saturated rock.
========================================================================================================================================
In the research area, microearthquake activity is a common phenomenon. Microearthquakes in the research area often occur due to the activity of high-pressure fluid injection. One of the things that can be done to support this can be done using the help of seismic tomography. Seismic tomography describes imaging based on measurements of microwave earthquake data depicted in an area of a geothermal field. Therefore, the purpose of this study is to investigate the geothermal area based on the structure of Vp, Vs, and the ratio Vp/Vs as well as the distribution of fluid distribution through the local earthquake tomography method. The method used is a method that utilizes micro earthquake data which is widely spread actively in a geothermal field area. The input data used in this research are station coordinate data, arrival time of P and S waves, 1D velocity model, and data from the hypocenter location. The data will be processed using SIMULPS12 software, then will be tested using a checkerboard resolution test to obtain areas that can later be interpreted further. Then it will be continued with the inversion which will produce a P and S wave velocity model. After that, it will be carried out iterations until the RMS value is <1 and if it still does not meet the standard, it will be repeated at the inversion stage. Based on the Vp, Vs, and Vp/Vs peda the steam zone in the northern part of the study with an elevation of -1.5 to 0 km and gets deeper towards the south with an increase of up to 1 km. Then in the east with a width of around 2 km which has a low Vp/Vs value with a value range of 1.6 – 1.70. Then the water zone is just below the steam zone with a high Vp/Vs value between 1.78 – 1.85. In general, the type of fluid in the research field is the type of vapor fluid zone used in the production area. However, the activity of meteoric water injection in the vicinity of the research site causes the vapor fluid layer below to have liquid fluid below it, which forms a cyclic system. The subsurface model of the research area consists of two main layers, namely steam-saturated rock, and water-saturated rock.
Item Type: | Thesis (Other) |
---|---|
Additional Information: | RSGf 551.22 Kin a-1 2022 |
Uncontrolled Keywords: | Geothermal Fields, Fluids Distribution, Microearthquake |
Subjects: | Q Science > QE Geology > QE538.5 Seismic tomography; Seismic waves. Elastic waves |
Divisions: | Faculty of Civil, Planning, and Geo Engineering (CIVPLAN) > Geophysics Engineering > 33201-(S1) Undergraduate Thesis |
Depositing User: | - Davi Wah |
Date Deposited: | 31 Oct 2023 08:37 |
Last Modified: | 31 Oct 2023 08:37 |
URI: | http://repository.its.ac.id/id/eprint/105021 |
Actions (login required)
View Item |