Peningkatan Efisiensi Energi di Zona Banjarmasin Utara dari Layanan Pompa Booster Banua Anyar di Perusahaan Air Minum Bandarmasih Kota Banjarmasin

Monangin, Galvani Amideo (2023) Peningkatan Efisiensi Energi di Zona Banjarmasin Utara dari Layanan Pompa Booster Banua Anyar di Perusahaan Air Minum Bandarmasih Kota Banjarmasin. Masters thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 6014221041-Master_Thesis.pdf] Text
6014221041-Master_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 April 2026.

Download (8MB) | Request a copy

Abstract

Salah satu permasalahan booster yang dialami oleh BUMD air minum adalah kurangnya efisiensi operasional yang berdampak pada kurangnya pembiayaan perusahaan air minum dalam pengembangan sistem penyediaan air minum. Kurangnya efisiensi operasional BUMD air minum dapat disebabkan oleh tingginya beban energi karena penggunaan energi yang tidak efisien. Topografi wilayah Kota Banjarmasin merupakan dataran sehingga sistem pengaliran menggunakan sistem perpompaan. Pompa booster Banua Anyar merupakan pompa distribusi yang mengalirkan air ke sebagian zona Banjarmasin Utara. Booster Banua anyar memiliki 3 buah pompa dengan efisiensi ketiganya dibawah 60 persen. Dibandingkan juga dengan 2 pompa booster lainnya yaitu booster S.Parman dan Gerilya, nilai SEC booster Banua Anyar adalah yang tertinggi dengan nilai sebesar 0,13. Biaya listrik pompa booster Banua Anyar pada tahun 2022 mencapai Rp. 1.521.737.167. Penelitian ini bertujuan untuk peningkatan efisiensi energi booster Banua Anyar. Perlunya upaya peningkatan efisiensi energi dengan melakukan pengukuran pemakaian energi, efisiensi kinerja pompa, dan analisis kondisi eksisting berupa simulasi hidrolis jaringan dengan menggunakan EPANET 2.2. Hasil tersebut akan digunakan sebagai dasar penentuan strategi peningkatan efisiensi energi jaringan distribusi dari pompa booster Banua Anyar. Berbagai alternatif strategi tersebut antara lain optimasi pompa, pengaturan VSD, dan pembangunan elevated reservoir. Upaya peningkatan efisiensi energi dikaji secara teknis, finansial dan aspek operasional untuk mengetahui kelayakannya. Hasil dari penelitian ini adalah adanya upaya peningkatan efisiensi energi berupa optimasi pompa (alternatif A) menghasilkan penghematan biaya listrik sebesar Rp. 87.107.040 per tahun , sedangkan pengaturan VSD (alternatif B) sebesar Rp. 122.015.520 per tahun dan pembangunan elevated reservoir (alternatif C) sebesar Rp. 194.983.560. Analisis aspek teknis untuk ketiga alternatif layak karena memenuhi syarat tekanan minimum sebesar 7,5 meter. Analisis aspek finansial menunjukkan bahwa alternatif A dan B layak secara finansial untuk dilaksanakan sehingga menjadi rekomendasi untuk dapat diterapkan di Perusahaan Air Minum Bandarmasih Kota Banjarmasin. Strategi dalam rangka penguatan aspek operasional di daerah layanan booster Banua Anyar antara lain pengembangan SDM bidang efisiensi energi, melengkapi peralatan dan SOP bidang efisiensi energi.
=================================================================================================================================
One of the challenges faced by the Regional Drinking Water Company (BUMD) is the lack of operational efficiency, leading to insufficient financing for the development of the water supply system. The operational inefficiency of BUMD can be attributed to the high energy load due to inefficient energy usage. The topography of Banjarmasin City is flat, requiring a pumping system for water distribution.. The Banua Anyar booster pump is a distribution pump that supplies water to parts of North Banjarmasin. The booster Banua Anyar has three pumps, each with an efficiency below 60 percent. Compared to two other booster pumps, namely S.Parman and Gerilya, the Specific Energy Consumption (SEC) value of the Banua Anyar booster is the highest at 0.13. The electricity cost for the Banua Anyar booster pump in 2022 reached IDR 1,521,737,167. This study aims to improve energy efficiency in the Banua Anyar booster. Efforts are needed to improve energy efficiency by measuring energy consumption, pump performance efficiency, and analyzing the existing conditions through hydraulic network simulation using EPANET 2.2. The results will be used as a basis for determining strategies to enhance the energy efficiency of the Banua Anyar booster pump distribution network. Various alternative strategies include pump optimization, Variable Speed Drive (VSD) regulation, and elevated reservoir construction. Efforts to improve energy efficiency are assessed technically, financially, and operationally to determine feasibility. The results of this research include efforts to improve energy efficiency through pump optimization (Alternative A), resulting in electricity cost savings of IDR 87,107,040 per year. Meanwhile, Variable Speed Drive regulation (Alternative B) provides savings of IDR 122,015,520 per year, and elevated reservoir construction (Alternative C) amounts to IDR 194.983.560. Technical analysis for all three alternatives shows feasibility as they meet minimum pressure requirements to 7,5 meters. Financial aspect analysis indicates that Alternatives A and B are financially viable and are recommended for implementation in the Bandarmasih City Water Company. Strategies to strengthen operational aspects in the Banua Anyar booster service area include human resource development in the field of energy efficiency, equipment upgrades, and the establishment of Standard Operating Procedures (SOP) in the field of energy efficiency.

Item Type: Thesis (Masters)
Uncontrolled Keywords: Air minum, Efisiensi energi, jaringan distribusi, pompa booster, Drinking water, Energy efficiency, Distribution network, Booster pump
Subjects: T Technology > TD Environmental technology. Sanitary engineering > TD259.2 Drinking water. Water quality
T Technology > TD Environmental technology. Sanitary engineering > TD395 Reservoirs (water supply)
T Technology > TD Environmental technology. Sanitary engineering > TD481 Water distribution systems
Divisions: Faculty of Civil, Planning, and Geo Engineering (CIVPLAN) > Environmental Engineering > 25101-(S2) Master Thesis
Depositing User: Galvani Amideo Monangin
Date Deposited: 15 Jan 2024 08:18
Last Modified: 15 Jan 2024 08:18
URI: http://repository.its.ac.id/id/eprint/105495

Actions (login required)

View Item View Item