Audit dan Konservasi Energi pada Rumah Pompa Kandangan PDAM Surya Sembada Kota Surabaya

Rifaldi, Reza (2023) Audit dan Konservasi Energi pada Rumah Pompa Kandangan PDAM Surya Sembada Kota Surabaya. Masters thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 6014221034-Master_Thesis.pdf] Text
6014221034-Master_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 June 2026.

Download (5MB) | Request a copy

Abstract

Pada tahun 2022, konsumsi energi di PDAM Surya Sembada Kota Surabaya sebesar 91.893.660 kWh/tahun. Berdasarkan Peraturan Menteri Energi dan Sumber Daya Mineral Republik Indonesia Nomor 14 Tahun 2012 Tentang Manajemen Energi, pengguna energi yang menggunakan energi lebih besar atau sama dengan 6.000 ton minyak/tahun atau sekitar 70.000.000 kWh/tahun wajib melakukan Manajemen Energi. Manajemen Energi yang dimaksud dilakukan dengan Audit dan Konservasi Energi. Penelitian ini bertujuan sebagai langkah awal PDAM dalam memenuhi kewajiban pengguna energi untuk melakukan manajemen energi. Berdasar hal tersebut, sebagai langkah awal manajemen energi secara menyeluruh pada PDAM maka dilakukan manajemen energi pada Rumah Pompa Kandangan yang merupakan salah satu rumah pompa yang berada pada PDAM Surya Sembada. Audit energi dilakukan dengan menganalisis kondisi eksisting pompa dan konsumsi energi. Metode analisis yang digunakan dalam penelitian ini adalah analisis jaringan distribusi dengan software WaterGEMS. Pada tahap konservasi energi dilakukan dengan menganalisis beberapa sumber energi baru terbarukan yang dapat diterapkan pada Rumah Pompa Kandangan. Analisis kelayakan finansial dengan metode PP dan BCR, dan analisis kelembagaan dengan metode SWOT. Hasil audit energi menunjukkan bahwa kondisi eksisting pompa dan konsumsi energi masih sangat baik, dengan nilai SEC ≤ 0,4 kWh/m3 dan efisiensi pompa ≥ 60%. Oleh karena itu dilakukan proyeksi pertumbuhan pelanggan untuk 5 tahun kedepan untuk melihat apakah kondisi pompa dan jaringan eksisting masih memadai. Hasil analisis teknis menunjukkan bahwa pompa dan jaringan eksisting saat ini tidak dapat melayani pelanggan dengan optimal pada 5 tahun kedepan. Biaya investasi untuk pembangunan elevated reservoir sebesar Rp. 2.362.500.000 dinilai kurang layak dari aspek finansial dengan nilai BCR 0,708. Hasil analisis peluang penerapan konservasi energi dinilai paling memungkinkan untuk diterapkan pada Rumah Pompa Kandangan adalah penggunaan solar panel dengan memanfaatkan sumber energi matahari. Biaya investasi yang dibutuhkan untuk penerapan konservasi energi sebesar Rp. 1.496.750.000. dinilai layak untuk diterapkan dengan indikator nilai BCR sebesar 3,987.
===================================================================================================================================
In 2022, the energy consumption at PDAM Surya Sembada in Surabaya City was 91,893,660 kWh per year. According to the Regulation of the Minister of Energy and Mineral Resources of the Republic of Indonesia Number 14 Year 2012 Regarding Energy Management, energy users with consumption equal to or greater than 6,000 metric tons of oil per year or approximately 70,000,000 kWh per year are required to implement Energy Management. The specified Energy Management involves both Energy Audit and Conservation. This research serves as the initial step for PDAM in fulfilling the energy user obligation to conduct energy management. Based on this, as an initial comprehensive energy management step at PDAM, energy management is implemented at the Kandangan Pump House, which is one of the pump houses located within PDAM Surya Sembada. The energy audit is conducted by analyzing the existing pump conditions and energy consumption. The analysis method employed in this research is distribution network analysis using WaterGEMS software. In the energy conservation phase, an analysis is carried out to assess several renewable energy sources that can be applied to the Kandangan Pump House. Financial feasibility analysis is performed using the Payback Period (PP) and Benefit-Cost Ratio (BCR) methods, along with institutional analysis using the SWOT method. The results of the energy audit indicate that the existing pump conditions and energy consumption are still very good, with a Specific Energy Consumption (SEC) value of ≤ 0.4 kWh/m3 and pump efficiency of ≥ 60%. Therefore, a customer growth projection for the next 5 years is conducted to assess whether the existing pump and network conditions are still adequate. Technical analysis results show that the current pumps and network cannot optimally serve customers in the next 5 years. The investment cost for the construction of an elevated reservoir is Rp. 2,362,500,000, deemed financially infeasible with a Benefit-Cost Ratio (BCR) of 0.708. The analysis of energy conservation opportunities indicates that the most viable option for the Kandangan Pump House is the implementation of solar panels, utilizing solar energy. The required investment cost for energy conservation implementation is Rp. 1,496,750,000, considered feasible with a BCR value of 3.987.

Item Type: Thesis (Masters)
Uncontrolled Keywords: Manajemen Energi, Audit Energi, Konservasi Energi, Energy Management, Energy Audit, Energy Conservation
Subjects: T Technology > TD Environmental technology. Sanitary engineering > TD233 Water consumption
T Technology > TD Environmental technology. Sanitary engineering > TD395 Reservoirs (water supply)
Divisions: Faculty of Civil, Planning, and Geo Engineering (CIVPLAN) > Environmental Engineering > 25101-(S2) Master Thesis
Depositing User: Reza Rifaldi
Date Deposited: 22 Jan 2024 00:21
Last Modified: 22 Jan 2024 00:21
URI: http://repository.its.ac.id/id/eprint/105572

Actions (login required)

View Item View Item