Abstract

Indonesia merupakan negara yang rawan mengalami bencana gempa bumi, salah satunya adalah di wilayah provinsi Sumatera Utara. Perkembangan dunia konstruksi dan keterbatasan lahan pemukiman menjadi salah satu alasan saat ini sering ditemui pembangunan Gedung bertingkat tinggi untuk mengembangkan sektor perbelanjaan dan hunian. Kerusakan pada infrasturktur bangunan akibat gempa menjadi salah satu perhatian khusus, sehingga pada konsep perencanaan struktur bangunan tahan gempa hal yang harus diperhitungkan adalah kemampuan struktur dalam memikul beban-beban yang bekerja, diantaranya beban gravitasi dan beban lateral. Sebagai alternatif maka dapat direncanakan bangunan dengan struktur baja – beton komposit yang menggunakan sistem steel plate shear wall (SPSW) sebagai struktur utama pemikul beban lateral. Terdapat beberapa keuntungan yang diperoleh dari penggunaan sistem steel plate shear wall apabila dibandingkan dengan shearwall beton yaitu memiliki kapabilitas kemampuan yang relatif besar untuk mendisipasi energi, kekakuan awal yang relatif tinggi, massa lebih ringan, fabrifikasi yang lebih mudah, dsb. Pada tugas akhir ini, Gedung Mall Cibinong Extension semula menggunakan material beton bertulang dengan pemikul utama beban lateralnya adalah shear wall beton yang memiliki tinggi 16 lantai dan dibangun di Kabupaten Bogor akan dimodifikasi ulang untuk dapat dibangun di Kota Dolok Sanggul, Sumatera Utara dengan penambahan menjadi 20 lantai menggunakan struktur baja – beton komposit dan pemikul utama beban lateralnya adalah steel plate shear wall tanpa pengaku (unstiffened). Studi literatur mengacu pada peraturan SNI 1729-2020, SNI 1726-2019, SNI 2847-2019, SNI 1727-2020, SNI 7860-2020, SNI 7972-2020, SNI 8460-2017, AISC 341-16, AISC 358-16, AISC 360-16, buku ajar dan jurnal yang berkaitan. Pada perencanaan ini diharapkan bahwa Gedung Mall Cibinong Extension dapat diaplikasikan untuk dibangun di Sumatera Utara dengan inovasi penggunaan struktur baja – beton komposit dengan sistem steel plate shear wall. Pemodelan struktur menggunakan ETABS yang disesuaikan dengan peraturan – peraturan yang digunakan. Berdasarkan hasil analisis dan perhitungan struktur, hasil yang diperoleh untuk perencanaan ini adalah menggunakan pelat lantai baja dengan tebal 90 – 110 mm. Balok induk komposit dengan profil baja WF 700x300x13x24, dimensi kolom terbesar adalah CFT 900x900x25. Untuk sistem SPSW profil yang digunakan berupa pelat baja yang membentang sepanjang 8 m dengan ketebalan paling besar 6 mm, VBE menggunakan CFT 900x900x85, HBE menggunakan profil baja WF 900x300x16x28. Pada sambungan baseplate digunakan ukuran pelat 110x110 cm dengan tebal 50 mm. Pondasi yang direncanakan adalah spun pile diameter 100 cm ddengan kedalaman 12 m dibawah permukaan tanah, dimensi kolom pedestal 1,2 m x 1,2 m yang dipasang sloof dengan dimensi 450x700 mm.
=================================================================================================================================
Indonesia is a country prone to earthquakes, one of which is in the province of North Sumatra. The development of world construction and settlement restrictions is one of the reasons currently often found the construction of high-rise buildings to develop the world and residential sectors. Damage to building infrastructure due to earthquakes is of particular concern, so that in the concept of earthquake resistant building is planning the thing that must be considered of structures ability to carry working loads, including gravity loads and lateral structural loads. As an alternative, a steel-concrete composite structure can be planned to use a steel plate shear wall (SPSW) system as the main structure for carrying lateral loads. There are several advantages to be gained from using a steel plate shear wall system when compared to concrete shear wall, such as having a relatively large capability for energy dissipation, relatively high initial stiffness, lighter mass, easier fabrication, etc. In this final project, the Cibinong Extension Mall Building originally used reinforced concrete material with the main bearer of the lateral load being a concrete shear wall which has a height of 16 floors and was built in Bogor Regency. It will be modified again to be built in Dolok Sanggul City, North Sumatra with an increase of 20 The floor uses a composite steel-concrete structure and the main bearer of the lateral load is a steel plate shear wall with stiffeners. Literature study refers to the regulations SNI 1729-2020, SNI 1726-2019, SNI 2847-2019, SNI 1727-2020, SNI 7860-2020, SNI 7972-2020, SNI 8460-2017, AISC 341-16, AISC 358-16, AISC 360-16, related textbook and journal. In this plan, it is hoped that the Cibinong Extension Mall Building can be applied to be built in North Sumatra with the innovative use of a composite steel-concrete structure with a steel plate shear wall system. Structural modeling uses ETABS which is adapted to the regulations used. Based on the results of structural analysis and calculations, the results obtained for this plan were to use steel floor plates with a thickness of 90 – 110 mm. Composite main beam with steel profile WF 700x300x13x24, largest column dimension is CFT 900x900x25. For the SPSW system, the profile used is a steel plate that stretches 8 m with a maximum thickness of 6 mm, VBE uses CFT 900x900x85, HBE uses WF 900x300x16x28 steel profile. For the baseplate connection, a plate size of 110x110 cm with a thickness of 50 mm is used. The planned foundation is a spun pile with a diameter of 100 cm with a depth of 12 m below the ground surface, pedestal column dimensions of 1.2 m x 1.2 m installed with a sloof with dimensions of 450x700 mm.

Item Type: Thesis (Other)
Uncontrolled Keywords: Gempa, Steel Plate Shear Wall, Struktur Baja – Beton Komposit.
Subjects: T Technology > TA Engineering (General). Civil engineering (General) > TA645 Structural analysis (Engineering)
T Technology > TA Engineering (General). Civil engineering (General) > TA658 Structural design
T Technology > TA Engineering (General). Civil engineering (General) > TA660.C6 Columns
T Technology > TA Engineering (General). Civil engineering (General) > TA775 Foundations.
Divisions: Faculty of Civil, Planning, and Geo Engineering (CIVPLAN) > Civil Engineering > 22201-(S1) Undergraduate Thesis