Pembuatan dan Pengujian Integrated Cervical and Lumbar Traction

Kevin, Adam (2024) Pembuatan dan Pengujian Integrated Cervical and Lumbar Traction. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 02111940000120-UnderGraduate_Thesis.pdf] Text
02111940000120-UnderGraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only

Download (16MB) | Request a copy

Abstract

Pada saat ini di zaman yang teknologi sangat berkembang dengan cepat. Hampir seluruh aktifitas yang dilakukan manusia berada didepan layar komputer sehingga membuat manusia akan menjalani harinya duduk dibelakang meja. Hal ini tanpa disadari dapat menyebabkan banyak dari mereka yang mengalami nyeri punggung ataupun leher.Berdasarkan data dari Badan Pusat Statistik (2018), terdapat 26,74% penduduk usia 15 tahun keatas yang bekerja mengalami keluhan dan gangguan kesehatan (Kemenkes RI, 2019). Semakin tua usia, semakin lama masa kerja dan semakin berisiko posisi saat bekerja maka responden cenderung lebih sering mengalami keluhan nyeri punggung bawah (Kumbea et al., 2021). Namun didalam penelitian ini juga banyak responden yang berada diusia 15 - 25 tahun yang mengalami nyeri punggung. Hal ini menegaskan bahwa nyeri punggung tidak memandang usia untuk menyerang siapapun. Karena sejatinya nyeri punggung pada usia 15 – 25 tahun ini, disebabkan oleh kesalahan postur tubuh ketika bekerja dalam jangka waktu yang lama. Untuk mengatasi masalah tersebut diatas, telah dirancang alat traksi lumbar dan servikal terintegrasi. Setelah tahap perancangan selesai, selanjutnya alat traksi lumbar dan servical dibuat menjadi sebuah prototipe. Oleh karena itu, pada tugas akhir ini akan dilakukan pembuatan dan pengujian prototipe alat traksi lumbar dan survikal dalam sebuah alat, dan dapat digunakan secara bersamaan. Langkah-langkah pada tugas akhir ini adalah studi literatur, dilanjutkan dengan perancangan proses manufaktur untuk direalisasi menjadi prototipe. Beberapa bagian dari alat traksi ada yang sudah tersedia di pasaran dan sisanya akan dilakukan proses manufacturing. Selanjutnya dilakukan perakitan komponen secara menyeluruh hingga menjadi sebuah prototipe. Langkah berikutnya adalah uji fungsi alat sesuai dengan standar. Dari rancangan yang sudah ditetapkan, selanjutnya dibuat sebuah prototipe traksi servikal dan lumbar dengan proses manufaktur yang paling utama adalah: Proses pemotongan dan pengelasan dengan menggunakan las SMAW. Perakitan dilakukan dengan merangkai beberapa komponen seperti kaki, main frame, traksi, hingga dongkrak. Berdasarkan dari hasil pengujian yang telah dilakukan, alat traksi yang telah dimanufaktur memiliki kekuatan rangka dan fungsi yang baik dan juga memiliki kekuatan tarik hingga mencapai 443,8 N.Pada hasil pengujian RULA bagian tubuh kiri mendapatkan hasil yang baik dengan skor 2, sedangkan pada tubuh bagian kanan mendapatkan skor 4 akibat dari responden memutar sendiri handle pemutar traksi secara mandiri. Hasil pengujian terhadap efek penurunan tingkat nyeri hanya mendapatkan hasil yang belum memuaskan. Dimana tingkat penurunan nyeri yang dihasilnya hanya berkisar pada 11,25%. Hal ini disebabkan karena pengujian masih membutuhkan waktu yang lebih lama dan respondennya yang memiliki kondisi kesehatan yang baik.
====================================================================================================================================
At this time in an age that technology is very rapidly developing. Almost all activities carried out by humans are in front of a computer screen so that humans will live their day sitting behind a desk. This can unwittingly cause many of them to experience back or neck pain. Based on data from the Central Statistics Agency (2018), there are 26.74% of people aged 15 years and over who work experiencing complaints and health problems (Ministry of Health RI, 2019). The older the age, the longer the working period and the more risky the work attitude, respondents tend to experience complaints of low back pain more often (Kumbea et al., 2021) But in this study also many respondents aged 15-25 years who experience back pain, this confirms that back pain does not look at age to attack anyone. Because true back pain at the age of 15-25 years, caused by postural errors when working for a long time. To overcome the above problems, integrated lumbar and cervical traction devices have been designed. After the design phase is complete, then tbbhe lumbar and cervical traction devices are made into a prototype. Therefore, in this final project, a prototype of lumbar and survikal traction devices will be made and tested in a tool and can be used simultaneously. The steps in this final project are a literature study, followed by designing the manufacturing process to be realized into a prototype. Some parts of the traction equipment are already available on the market and the rest will be carried out in the manufacturing process. Furthermore, a thorough assembly of components is carried out until it becomes a prototype. The next step is to test the functionality of the tool according to the standard. From the design that has been determined, then a cervical and lumbar traction prototype is made with the most important manufacturing process is: Cutting and welding process using SMAW welding. Assembly is done by assembling several components such as legs, main frame, traction, to jacks. Based on the results of the tests that have been carried out, traction tools that have been manufactured have good frame strength and function and have tensile strength up to 443.8 N. In the RULA test results the left body gets good results with a score of 2, while on the right body gets a score of 4 due to respondents turning the traction turning handle independently. The results of testing on the effect of reducing pain levels only get unsatisfactory results. Where the resulting pain reduction rate is only around 11.25%. This is because testing still takes longer and the respondents have good health conditions

Item Type: Thesis (Other)
Uncontrolled Keywords: Chronic Low Back Pain, Cervical Traction, Lumbar Traction
Subjects: T Technology > TS Manufactures > TS170 New products. Product Development
Divisions: Faculty of Industrial Technology and Systems Engineering (INDSYS) > Mechanical Engineering > 21201-(S1) Undergraduate Thesis
Depositing User: Adam Kevin
Date Deposited: 15 Feb 2024 03:43
Last Modified: 15 Feb 2024 03:43
URI: http://repository.its.ac.id/id/eprint/107169

Actions (login required)

View Item View Item