Fernandes, Nelia Noronha (2024) Pengukuran Dan Pendeteksian Carotid Arteri Pada Leher Dari Citra Mesin Usg Portable. Other thesis, Institut Teknologi Sepuluh Nopember.
Text
07311740007004-Undergraduate_Theses.pdf - Accepted Version Restricted to Repository staff only until 1 April 2026. Download (5MB) | Request a copy |
Abstract
Objek penelitian ini bertujuan untuk menambahkan informasi pada sistem ultrasound agar dapat membantu para ahli medis. Penggunaan mesin usg portable sudah banyak digunakan namun perlu penambahan fitur tertentu agar dapat berfungsi lebih baik. Tugas akhir ini bertujuan untuk melakukan pengambilan data citra carotid dari pasien menggunakan mesin usg portable, lalu citra ini kemudian diprosses lebih lanjut agar dapat di ukur property dari carotid tersebut. Arteri carotid adalah arteri besar dimana denyutnya dapat dirasakan pada pembuluh darah arteri di kedua sisi leher dibawah rahang. Pembuluh darah arteri carotis interna memasok aliran darah ke otak dan arteri carotis externa memasok persediaan darah ke wajah. Percabangan seperti garpu tala ini adalah situs/ daerah umum yang memungkinlan terjadinya aterosklerosis, suatu inflamasi penumpukan plak yang dapat mempersempit arteri externa atau interna. Penanganan untuk penyumbatan pembuluh darah dilakukan dengan metode katerisasi. Namun metode ini tidak aman dikarenakan metode ini masih menggunakan x-ray untuk menemukan kepala kateter. X-ray dapat mengakibatkan kanker apabila dilakukan terus menerus. Sehingga cara lain yang dapat digunakan yaitu dengan menggunakan ultrasonografi yang tergantung dengan posisi dan orientasi probe USG pada saat pengambilan citra. Dengan berbasis sinyal ultrasonic, alat ini dapat menghasilkan citra di bagian dalam tubuh. Dalam tugas akhir ini melakukan pengukuran luas keliling dari carotid arteri dengan menggunakan mesin citra USG portable pada sistem ultrasound, gambar citra yang didapat, kemudian diprosses dengan menggunakan python pada saat diprosses gambar citra melewati beberapa tahapan yaitu melakukan imag enhancement dengan meningkatkan kontras pada gambar lalu melakukan cropping pada daerah yang ingin diprosses. Kemudian di atur nilai pixel spacinnya. Di sini sangat penting untuk mengatur nilai pixel spacingnya karena jika tidak sesuai maka hasil yang didapatkan pun akan jauh berbeda dengan nilai aslinya sehingga dapat menimbulkan nilai error yang tinggi, disini nilai pixel spacing di atur [0.075, 0.078] dengan jarak antara sumbu x dan sumbo y untuk dapat memperoleh nilai dari area dan perimeter dari carotid arteri yang mendekati nilai asli. =================================================================================================================================
This research object aims to add information to the ultrasound system in order to help medical experts. The use of portable ultrasound machines has been widely used but needs the addition of certain features to function better. This final project aims to collect carotid image data from patients using a portable ultrasound machine, then this image is then processed further so that the property of the carotid can be measured. The carotid artery is a large artery whose pulsation can be felt in the arterial blood vessels on both sides of the neck under the jaw. The internal carotid arteries supply blood to the brain and the external carotid arteries supply blood to the face. These tuning fork-like branches are common sites for atherosclerosis, an inflammatory plaque buildup that can narrow the external or internal arteries. Handling for blockage of blood vessels is done by the catheterization method. However, this method is not safe because this method still uses x-rays to find the catheter head. X-rays can cause cancer if done continuously. So that another way that can be used is to use ultrasound which depends on the position and orientation of the ultrasound probe when taking the image. Based on ultrasonic signals, this tool can produce images on the inside of the body. In this final project, measuring the circumference of the carotid arteries using a portable ultrasound image machine on the ultrasound system, the images obtained are then processed using Python. When the images are processed, the images go through several stages, namely performing image enhancement by increasing the contrast in the image and then cropping the area to be processed. Then set the pixel spacing value. Here it is very important to set the pixel spacing value because if it is not appropriate then the results obtained will be much different from the original value so that it can cause a high error value, here the pixel spacing value is set [0.075, 0.078] with the distance between the x axis and the y axis to be able to obtain values from the area and perimeter of the carotid artery that are close to the original value.
Item Type: | Thesis (Other) |
---|---|
Uncontrolled Keywords: | Carotid Artery, Blood Vessel, Ultrasound |
Subjects: | R Medicine > R Medicine (General) > R856.2 Medical instruments and apparatus. R Medicine > RZ Other systems of medicine |
Divisions: | Faculty of Intelligent Electrical and Informatics Technology (ELECTICS) > Biomedical Engineering > 11410-(S1) Undergraduate Thesis |
Depositing User: | Nelia Noronha Fernandes |
Date Deposited: | 28 Feb 2024 02:47 |
Last Modified: | 28 Feb 2024 02:47 |
URI: | http://repository.its.ac.id/id/eprint/107723 |
Actions (login required)
View Item |