Analisis dan Simulasi Parameter Akustik Ruang pada Auditorium Sekolah CHS sebagai Multifunction Room

Widyastuti, Yurina (2024) Analisis dan Simulasi Parameter Akustik Ruang pada Auditorium Sekolah CHS sebagai Multifunction Room. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 5001201092-Undergraduate_Thesis.pdf] Text
5001201092-Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 April 2026.

Download (12MB) | Request a copy

Abstract

Pentingnya kualitas akustik dalam ruang auditorium sebagai tempat multifungsi menjadi fokus utama penelitian ini. Gedung Auditorium CHS, yang sering menjadi tuan rumah berbagai acara penting, menjadi objek kajian untuk mengevaluasi dan mengoptimalkan parameter akustiknya. Penelitian ini bertujuan untuk melakukan dan mengetahui optimasi serta evaluasi parameter-parameter akustik yang digunakan pada Gedung CHS sebagai multifunction room dan untuk melakukan perancangan perbaikan akustik ruang Gedung Auditorium CHS. Metode yang digunakan pada penelitian ini yaitu dengan menggunakan metode impulse response dengan pengukuran melalui simulasi software Ease 4.3 dan pengukuran secara langsung. Analisis dimulai dengan mengamati nilai Background Noise pada Noise Criteria (NC), waktu dengung (RT), clarity (C80), definition (D50), serta sebaran SPL. Berdasarkan hasil pengukuran nilai NC adalah 30 dB. Hal ini menandakan bahwa kebisingan dalam ruangan tersebut termasuk dalam batas wajar karena sudah sesuai dengan standar preferensi. Kedua, untuk SPL pada sumber depan selisihnya sebesar 7 dBA, hal ini menandakan persebaran SPL pada ruangan tersebut belum merata. Ketiga, waktu dengung pada ruangan tersebut bernilai 1,12 s -1,69 s pada semua frekuensi dengan sumber panggung, sedangkan pada frekuensi 1000 Hz dengan sumber panggung bernilai 1, 16 s – 1,58 s. Hal ini menandakan waktu dengung pada ruang tersebut sudah sesuai dengan preferensi sehingga suara yang dihasilkan dapat terdengar jelas. Keempat, nilai clarity sebesar -2 – 2,2 dBA, hal ini menandakan bahwa nilai clarity sudah memenuhi standar preferensi. Sehingga kualitas kejelasan musik pada ruangan ini sudah bagus dan layak. Kelima, nilai definition sebesar 45% sehingga sudah sesuai dengan preferensi yang ada terkait kejelasan ucapan. Untuk merancang perbaikan kualitas akustik ruang pada Gedung CHS, dilakukan dengan melakukan penambahan speaker pada area tengah samping kanan dan samping kiri. Hal ini dilakukan guna meningkatkan kualitas SPL yang lebih merata daripada sebelumnya. Terbukti setelah ditambahkan speaker nilai selisih SPL dari titik terjauh dan terdekat sebesar 5 dBA.
=================================================================================================================================
The importance of acoustic quality in auditorium spaces as multifunctional venues is the main focus of this study. The CHS Auditorium Building, which often hosts various important events, is the object of study to evaluate and optimize its acoustic parameters. This study aims to conduct and determine the optimization and evaluation of acoustic parameters used in the CHS Building as a multifunction room and to design acoustic improvements in the CHS Auditorium Building space. The method used in this study is to use the impulse response method with measurements through Ease 4.3 software simulations and direct measurements. The analysis begins by observing the Background Noise value on Noise Criteria (NC), reverberation time (RT), clarity (C80), definition (D50), and SPL distribution. Based on the measurement results, the NC value is 30 dB. This indicates that the noise in the room is within reasonable limits because it is in accordance with the preference standard. Second, for the SPL at the front source the difference is 7 dBA, indicating that the SPL distribution in the room is uneven. Third, the reverberation time in the room is 1.12 s -1.69 s at all frequencies with the stage source, while at a frequency of 1000 Hz with the stage source it is 1.16 s - 1.58 s. This indicates that the reverberation time in the room is in accordance with preferences so that the sound produced can be heard clearly. Fourth, the clarity value is -2 - 2.2 dBA, this indicates that the clarity value has met the preference standard. So that the quality of music clarity in this room is good and feasible. Fifth, the definition value is 45% so that it is in accordance with existing preferences regarding speech clarity. To design improvements to the acoustic quality of space in the CHS Building, it is done by adding speakers to the center area on the right side and left side. This is done to improve the quality of SPL which is more evenly distributed than before. It is proven that after adding speakers the SPL difference value from the farthest and closest points is 5 dBA.

Item Type: Thesis (Other)
Uncontrolled Keywords: Akustik Ruang Multifungsi, Impulse Response, Parameter Akustik, Acoustic Parameters, Multifunctional Room Acoustics
Subjects: Q Science > QC Physics > QC221 Acoustics. Sound
Divisions: Faculty of Science and Data Analytics (SCIENTICS) > Physics > 45201-(S1) Undergraduate Thesis
Depositing User: Yurina Widyastuti
Date Deposited: 28 Feb 2024 03:22
Last Modified: 28 Feb 2024 03:22
URI: http://repository.its.ac.id/id/eprint/107728

Actions (login required)

View Item View Item