Analisis Sebaran Dosis Pesawat Sinar X Konvensional Dengan Menggunakan Thermoluminescence Dosimeter

Cindyanti, Nabilla Putri (2022) Analisis Sebaran Dosis Pesawat Sinar X Konvensional Dengan Menggunakan Thermoluminescence Dosimeter. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 01111840000093-Undergraduate_Thesis.pdf] Text
01111840000093-Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only until September 2024.

Download (1MB)

Abstract

Penelitian bertujuan untuk mengetahui persebaran dosis dan kesesuaian standar pada pesawat sinar-X konvensional. Penelitian diawali dengan proses annealing pada thermoluminescence dosimeter kemudian diikuti dengan pengelompokkan TLD sesuai dengan kepekaan masing-masing. Penyinaran TLD oleh pesawat sinar-x konvensional dilakukan dengan menempatkan TLD-100 pada posisi titik yang dipetakan dengan menggunakan isolasi plastik yang di tempel pada lantai di dalam area kolimator. Proses pemetaan dilakukan dengan dua variasi ketinggian yang berbeda terhadap sumber radiasi yaitu 1 meter dan 2 meter dan juga menempatkan dua titik TLD-100 diluar ukuran bidang kalimator dengan setiap jaraknya 1 cm. Nilai dosis serap radiasi hasil pembacaan dari TLD Reader Harshaw model 3500 yang terintegrasi dengan software WinREMS memiliki nilai sebesar 0.74 mGy pada ketinggian 2 meter dan sebesar 2.4 mGy pada ketinggian 1 meter dari sumber pada koordinat (0,0). Untuk pengukuran di luar ukuran bidang kolimator (area sumber radiasi) memberikan bacaan dosis dengan nilai tertinggi 0.25 mGy untuk ketinggian 2 meter dan 0.28 mGy untuk ketinggian 1 meter. Berdasarkan hasil pemetaan, dapat diketahui nilai dosis serap pada ketinggian 1 meter lebih besar dibandingkan pada ketinggian 2 meter, hal ini menunjukkan hubungan intensitas radiasi berkurang dengan meningkatnya jarak dari sumber radiasi. Hal ini disebut juga dengan hukum kuadrat terbalik. Hukum kuadrat terbalik dapat artikan bila jarak dari sumber radiasi meningkat dua kali lipat, maka dosis menurun menjadi ¼ dari semula. Terdapat pula nilai error yang tidak diinginkan terjadi pada saat pembacaan nilai dosis serap, hal ini dikarenakan adanya faktor anomali dari adanya tegangan listrik di sekitar ruangan radiografi, adanya debu-debu di sekitar tempat pembacaan tld yang berpendar ketika berlangsungnya proses pembacaan TLD-100.
================================================================================================================================
The aim of the study was to determine the dose distribution and conformity of standards on conventional X-ray machines. The research began with the annealing process on the thermoluminescence dosimeter then followed by grouping the TLD according to their respective sensitivities. TLD irradiation by conventional x-ray machines is carried out by placing the TLD-100 at the position of the mapped points using plastic insulation attached to the floor in the collimator area. The mapping process is carried out with two different height variations of the radiation source, 1 meter and 2 meters and also placing two TLD-100 points outside the size of the collimator area with a distance of 1 cm each. The value of absorbed radiation dose reading from TLD Reader Harshaw model 3500 which is integrated with WinREMS software has a value of 0.74 mGy at a height of 2 meters and 2.4 mGy at a height of 1 meter from the source at coordinates (0,0). For measurements outside the collimator field size (radiation source area) it provides a voltage response with the highest value of 0.25 mGy for a height of 2 meters and 0.28 mGy for a height of 1 meter. Based on the mapping results, it can be seen that the absorbed dose value at a height of 1 meter is greater than at a height of 2 meters, this shows that the relationship between radiation intensity decreases with increasing distance from the radiation source. This is also known as the inverse square law. The inverse square law means that if the distance from the radiation source is doubled, the dose will decrease to from the original. There is also an unwanted error value that occurs when reading the absorbed dose value, this is due to anomalous factors from the electrical voltage around the radiography room, the presence of dust around the TLD-100 reading area that glows during the TLD-100 reading process

Item Type: Thesis (Other)
Additional Information: RSFi 616.075 7 Cin a-1
Uncontrolled Keywords: Thermoluminescence Dosimeter , Sinar-X, Dosis Radiasi
Subjects: Q Science > QC Physics > QC100.5 Measuring instruments (General)
Divisions: Faculty of Science and Data Analytics (SCIENTICS) > Physics > 45201-(S1) Undergraduate Thesis
Depositing User: Mr. Tondo Indra Nyata
Date Deposited: 07 Mar 2024 04:39
Last Modified: 07 Mar 2024 04:39
URI: http://repository.its.ac.id/id/eprint/107782

Actions (login required)

View Item View Item