Putra, Edo Fernando (2022) Analisis Harmonisa Akibat Rekonfigurasi Sistem Distribusi AC Menjadi DC Dengan Sumber Listrik Hybrid Diesel Generator Dan Sel Photovoltaic Pada Kapal Tanker. Other thesis, Institut Teknologi Sepuluh Nopember.
Text
04211840000037-Undergraduate_Thesis.pdf - Accepted Version Restricted to Repository staff only until 1 October 2026. Download (2MB) | Request a copy |
Abstract
Harmonisa merupakan distorsi gelombang yang dihasilkan oleh beban non linier pada sistem distribusi listrik. Beban non linier bersumber dari converter, dan beban statis. Harmonisa akan dianalisis pada 2 sistem distribusi yakni AC, dan DC. Terbagi menjadi 4 kondisi yakni, at port, leaving arriving, loading unloading, dan sailing. Analisis dilakukan dengan tujuan untuk mengetahui pengaruh harmonisa pada rekonfigurasi sistem distribusi AC menjadi DC. Analisis dilakukan menggunakan perangkat lunak simulator sistem distribusi listrik. Dihasilkan nilai harmonisa terbesar pada sistem distribusi AC terdapat pada kondisi at port pada bus DB L-6 yakni 3,75%. Pada sistem distribusi DC dihasilkan nilai harmonisa terbesar pada kondisi loading unloading Bus Floor 1 dengan nilai 13,90% THD. Dalam melakukan rekonfigurasi sistem distribusi AC menjadi DC terjadi kenaikan pada harmonisa di sistem distribusi DC. Beberapa busbar sistem distribusi DC tidak memenuhi standar yang dikeluarkan oleh aturan BKI vol. IV part 1 sec. 4 bagian 11.1 mengatur bahwa total harmonic distortion (THD) tidak boleh lebih dari 8%. Sehingga dibutuhkan filter harmonisa untuk mengurangi distorsi gelombang. Setelah pemasangan filter Seluruh busbar sudah memenuhi nilai THD yang ditetapkan oleh BKI.
===================================================================================================================================
Harmonics are wave distortions produced by non-linear loads on an electrical distribution system. Non-linear loads are sourced from the converter, and static loads. Harmonics will be analyzed in 2 distribution systems, namely AC and DC. It is divided into 4 conditions, namely, at port, leaving arriving, loading unloading, and sailing. The analysis was carried out with the aim of knowing the effect of harmonics on reconfiguring the AC distribution system to DC. The analysis was carried out using simulator electrical distribution software. The largest harmonic values are generated in the condition of the AC distribution system at port in DB L 6 which is 3.75%. The DC distribution system produces the greatest harmonic values in the conditions at loading unloading conditions of the 1st Floor Bus with a value of 13.90% THD. In reconfiguring the AC distribution system to DC, the harmonics in the DC distribution system increase. Some DC busbar distribution systems do not the standards issued by BKI rules vol. IV part 1 second. 4 section 11.1 regulate that the total harmonic distortion (THD) cannot be more than 8%. So we need a harmonic filter to reduce wave distortion. After installing the harmonic filter, the results all of bus not under 8%.
Item Type: | Thesis (Other) |
---|---|
Additional Information: | RSPe 621.319 Put a-1 2022 |
Uncontrolled Keywords: | Harmonisa, Sistem Distribusi AC, Sistem Distribusi DC, Total Harmonic Distortion (THD), Harmonic, AC Distribution System, DC Distribution System, Total Harmonic Distortion |
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK3030 Electric power distribution systems T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK3226 Transients (Electricity). Electric power systems. Harmonics (Electric waves). |
Divisions: | Faculty of Marine Technology (MARTECH) > Marine Engineering > 36202-(S1) Undergraduate Thesis |
Depositing User: | - Davi Wah |
Date Deposited: | 30 May 2024 08:13 |
Last Modified: | 30 May 2024 08:13 |
URI: | http://repository.its.ac.id/id/eprint/107971 |