Perhitungan Time Dial Setting Inverse Time Overcurrent Relay Dengan Metode Adaptive Modified Firefly Algorithm Pada Sistem Kelistrikan PT. Linde Gresik

Shabira, Mahila (2024) Perhitungan Time Dial Setting Inverse Time Overcurrent Relay Dengan Metode Adaptive Modified Firefly Algorithm Pada Sistem Kelistrikan PT. Linde Gresik. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 5022201079_Undergraduate_Thesis.pdf] Text
5022201079_Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 October 2026.

Download (11MB) | Request a copy

Abstract

Dalam sistem kelistrikan suatu industri, menjaga kelancaran pasokan tenaga listrik sangat penting agar proses produksi dapat berjalan tanpa hambatan. Sistem proteksi tenaga listrik yang terkoordinasi dengan baik dibutuhkan untuk mencegah terjadinya kesalahan koordinasi, blackout, dan hal-hal yang tidak diinginkan lainnya. Selain diperlukanya peralatan yang handal untuk menunjang sistem proteksi, pemilihan parameter proteksi yang tepat pada sistem proteksi kelistrikan suatu industri juga sangat diperlukan. Salah satu parameter tersebut adalah Time Dial Setting (TDS) yang berfungsi mengatur waktu operasi rele untuk mengamankan gangguan. Umumnya nilai TDS koordinasi proteksi rele arus lebih didapatkan dari perhitungan manual untuk mendapatkan nilai minimumnya dan menggunakan metode trial and error dengan menggeser kurva rele untuk mendapatkan nilai CTI yang tepat. Untuk memudahkan dan mendapatkan hasil TDS yang tepat maka dapat digunakan suatu algoritma khusus. Pada penelitian ini akan dibahas tentang cara perhitungan time dial setting inverse time overcurrent relay dengan metode adaptive modified firefly algorithm pada sistem kelistrikan PT. Linde Gresik untuk mendapatkan nilai TDS yang minimum. Hasil akhir penelitian ini yakni memperoleh setting TDS yang tepat dengan waktu operasi dan CTI yang minimum serta pemilihan kurva TCC guna mengetahui bahwa koordinasi proteksi sudah tepat. Hasil dari tugas akhir ini adalah program yang mampu menghasilkan nilai Time Dial Setting (TDS) minimum yang akurat sesuai dengan perhitungan manual. Program ini juga memastikan waktu operasi dan Coordination Time Interval (CTI) yang minimum beserta plot kurva Time Current Characteristic (TCC) untuk memastikan bahwa koordinasi proteksi sudah tepat.
===================================================================================================================================
In the electrical system of an industrial plant, ensuring a smooth power supply is crucial for uninterrupted production processes. A well-coordinated power protection system is necessary to prevent coordination errors, blackouts, and other undesirable incidents. In addition to reliable equipment to support the protection system, selecting the appropriate protection parameters in the electrical system of an industrial plant is highly important. One of these parameters is the Time Dial Setting (TDS), which regulates the operating time of relays to secure against faults. Generally, the TDS values for coordinated overcurrent relay protection are obtained through manual calculations to find the minimum values, using trial and error methods by shifting the relay curves to achieve the appropriate CTI (Coordination Time Interval) value. To simplify and obtain accurate TDS values, a specific algorithm can be utilized. This thesis will discuss the calculation of the time dial setting for inverse time overcurrent relays using the adaptive modified firefly algorithm in the electrical system of PT. Linde Gresik to obtain the minimum TDS value. The result of this thesis is a program that can produce accurate minimum TDS values according to manual calculations. This program also ensures minimum operation time and Coordination Time Interval (CTI) and includes a plot of the Time Current Characteristic (TCC) curve to make sure that the protection coordination is correct.

Item Type: Thesis (Other)
Uncontrolled Keywords: Koordinasi Proteksi, Time Dial Setting, Adaptive Modified Firefly Algorithm, Protection Coordination
Subjects: Q Science > QA Mathematics > QA9.58 Algorithms
T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK2861 Electric relays. Protective relays--Security measures.
Divisions: Faculty of Intelligent Electrical and Informatics Technology (ELECTICS) > Electrical Engineering > 20201-(S1) Undergraduate Thesis
Depositing User: Mahila Shabira
Date Deposited: 30 Jul 2024 06:00
Last Modified: 30 Jul 2024 06:00
URI: http://repository.its.ac.id/id/eprint/108909

Actions (login required)

View Item View Item