Analisis Kestabilan Transient dan Penyempurnaan Sistem Load Shedding Pada PT Linde Gresik Akibat Pemindahan Supply dan Penambahan Beban

Dzakiri, Elyan Rizqi (2024) Analisis Kestabilan Transient dan Penyempurnaan Sistem Load Shedding Pada PT Linde Gresik Akibat Pemindahan Supply dan Penambahan Beban. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of Tugas Akhir FIX_Elyan Rizqi D.pdf] Text
Tugas Akhir FIX_Elyan Rizqi D.pdf - Accepted Version
Restricted to Repository staff only until 1 October 2026.

Download (9MB) | Request a copy

Abstract

Gas industri dan teknologi yang dikembangkan oleh Linde memiliki peran penting dalam berbagai aplikasi di Indonesia. Pada tahun 2023, PT Linde Gresik melakukan pemindahan dan penambahan pasokan listrik dari 20KV menjadi 150KV. Penambahan pasokan ini dilakukan sebagai respons terhadap peningkatan daya yang awalnya sebesar 32MW menjadi 55MW. Namun, peningkatan daya ini menyebabkan breaking ampere tidak mampu menanggung arus hubung singkat yang tinggi. Sebagai hasilnya, pasokan listrik dari PLN dipindahkan dari satu lokasi ke lokasi lainnya dan breaking ampere pada sirkuit pemutus arus ditingkatkan dari 22KA menjadi 40KA. Namun demikian, hal tersebut masih belum memadai, sehingga impedansi pada transformator juga ditingkatkan sebesar 22% dari PLN. Tugas akhir ini bertujuan untuk menganalisis kestabilan transient dengan studi kasus trip generator sebelum dan setelah PLN trip dan hubung singkat yang dilengkapi dengan skema pelepasan beban sesuai permintaan PT Linde. Pada penelitian ini diberikan rekomendasi pelepasan beban status minimal sebesar 28,7 MW ketika terjadi gangguan PLN trip ketika 4 pembangkit beroperasi dan ketika terjadi PLN serta generator trip ketika 5 pembangkit beroperasi. Sedangkan untuk pelepasan beban secara UFR dapat dilakukan pelepasan beban sebesar 29,9 MW pada kasus 1 generator trip dan 32,2 MW pada kasus 2 generator trip. Kemudian melakukan studi short circuit dengan mitigasi membuka CB dan studi motor starting dengan dipilih motor dengan beban terbesar (4,5 MW) didapatkan hasil frekuensi, tegangan, dan sudut rotor kembali stabil ke keadaan baru.
==================================================================
Industrial gases and technologies developed by Linde play a vital role in various applications across Indonesia. In 2023, PT Linde Gresik undertook the relocation and augmentation of its power supply from 20KV to 150KV. This power supply increase was implemented in response to a capacity expansion from an initial 32MW to 55MW. However, this capacity upgrade rendered the existing breaking ampere incapable of handling the high short-circuit current. Consequently, the power supply from PLN (Indonesia's state-owned power utility) was shifted from one location to another, and the breaking ampere on the circuit breaker was increased from 22KA to 40KA. Nonetheless, this measure remained insufficient, prompting an impedance increase of 22% in the transformer supplied by PLN. This thesis aims to analyze transient stability through a case study of generator trip before and after PLN trip and short circuit, incorporating load shedding schemes as requested by PT Linde. The study provides recommendations for minimum status load shedding of 28.7 MW during PLN trip events with 4 generators in operation, and 28.7 MW during PLN and generator trip events with 5 generators in operation. For UFR-based load shedding, a load shedding of 29.9 MW is recommended for 1 generator trip and 32.2 MW for 2 generator trip scenarios. Further analysis involving circuit breaker opening mitigation and motor starting studies, selecting the motor with the largest load (4.5 MW), revealed that the frequency, voltage, and rotor angle stabilize back to a new steady state.

Item Type: Thesis (Other)
Uncontrolled Keywords: Gangguan Transient, Pelepasan Beban, PT Linde Gresik, PLN Trip Transient Disturbance, Load Shedding
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK1010 Electric power system stability. Electric filters, Passive.
Divisions: Faculty of Electrical Technology > Electrical Engineering > 20201-(S1) Undergraduate Thesis
Depositing User: Elyan Rizqi Dzakiri
Date Deposited: 26 Jul 2024 02:49
Last Modified: 26 Jul 2024 02:49
URI: http://repository.its.ac.id/id/eprint/108939

Actions (login required)

View Item View Item