Mumtazy, Muhammad Robich (2024) Studi Pemilihan Titik Lokasi Pentanahan Tunggal Terhadap Sambaran Petir Langsung pada Sistem Panel Surya. Other thesis, Institut Teknologi Sepuluh Nopember.
Text
5022201233-Undergraduate_Thesis.pdf - Accepted Version Restricted to Repository staff only until 1 October 2026. Download (6MB) | Request a copy |
Abstract
Panel surya merupakan salah satu alternatif teknologi ramah lingkungan yang berperan penting dalam pembangkitan listrik. Namun, pemasangan panel surya di tempat terbuka juga meningkatkan risiko terjadinya sambaran petir langsung sehingga dapat peralatan panel surya meskipun telah dilengkapi dengan sistem perlindungan petir. Sistem pentanahan menjadi faktor penting dalam mengatasi sambaran petir. Tanpa adanya sistem pentanahan yang baik, panel surya dan komponen pendukungnya rentan mengalami kerusakan fatal. Oleh karena itu, penelitian ini dilakukan untuk mengkaji rancangan sistem pentanahan yang efektif dalam menanggulangi tegangan berlebih yang mungkin terjadi pada panel surya. Studi ini berfokus pada penggunaan titik pentanahan tunggal pada sistem panel surya dengan titik pentanahan yang terhubung dengan frame atau mounting dari panel surya. Penelitian ini bertujuan untuk mengetahui pengaruh titik pentanahan terhadap karakteristik tegangan jatuh. Penelitian ini dilakukan dengan melakukan variasi terhadap nilai resistivitas tanah untuk mengetahui karakteristik tegangan jatuh yang terukur. Berdasarkan hasil simulasi yang dilakukan, semakin tinggi nilai resistivitas tanah yang digunakan mengakibatkan tegangan puncak yang terukur mengalami kenaikan yang cukup signifikan. Kenaikan ini disebabkan nilai resistivitas tanah menyebabkan impedansi pada sistem pentanahan mengalami kenaikan. Pada variasi selanjutnya, dilakukan percobaan dengan melakukan variasi pada titik lokasi pentanahan. Berdasarkan data percobaan, untuk titik lokasi pentanahan yang jauh dari sumber petir menunjukkan bahwa jalur petir menuju titik pentanahan semakin jauh sehingga nilai puncak tegangan semakin meningkat. Sebaliknya, jika titik pentanahan semakin dekat dengan sumber petir maka nilai puncak tegangan yang terukur semakin rendah. Melalui hasil simulasi juga didapatkan hasil berupa penggunaan dua titik grounding mampu menurunkan nilai tegangan puncak pada pemodelan rangkaian. Dari penelitian ini, diharapkan penelitian ini dapat memberikan pemahaman yang lebih mendalam tentang pentanahan pada panel surya serta membantu dalam merancang sistem pentanahan yang aman dan efisien.
=================================================================================================================================
Solar panels are one of the environmentally friendly technology alternatives that play an important role in power generation. However, installing solar panels in open spaces also increases the risk of direct lightning strikes, which can damage solar panel equipment even though it is equipped with a lightning protection system. The grounding system is an important factor in overcoming lightning strikes. Without a good grounding system, solar panels and their supporting components are prone to fatal damage. Therefore, this study is conducted to assess the design of an effective grounding system in dealing with overvoltage that may occur in solar panels. This study focuses on the use of a single grounding point on a solar panel system with a grounding point connected to the frame or mounting of the solar panel. This study aims to determine the effect of the grounding point on the characteristics of the voltage drop. This study was conducted by varying the soil resistivity value to determine the characteristics of the measured voltage drop. Based on the results of the simulation, the higher the soil resistivity value used, the more significant the measured peak voltage increases. This increase is caused by the soil resistivity value causing the impedance on the grounding system to increase. In the next variation, an experiment was conducted by varying the grounding location point. Based on experimental data, for grounding locations that are far from the lightning source, the path of lightning to the grounding point is further away so that the peak voltage value increases. Conversely, if the grounding point is closer to the lightning source, the measured peak voltage value is lower. Through the simulation results, the results were also obtained in the form of using two grounding points to reduce the peak voltage value in the circuit modeling. From this study, it is hoped that this study can provide a deeper understanding of grounding in solar panels and help in designing a safe and efficient grounding system.
Item Type: | Thesis (Other) |
---|---|
Uncontrolled Keywords: | solar panels, lightning, grounding system, soil resistivity, panel surya, petir, sistem pentanahan, tahanan tanah. |
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK153 Electric power factor. Lightning protection. |
Divisions: | Faculty of Intelligent Electrical and Informatics Technology (ELECTICS) > Electrical Engineering > 20201-(S1) Undergraduate Thesis |
Depositing User: | Muhammad Robich Mumtazy |
Date Deposited: | 29 Jul 2024 02:58 |
Last Modified: | 29 Jul 2024 02:58 |
URI: | http://repository.its.ac.id/id/eprint/109524 |
Actions (login required)
View Item |