Modifikasi Perencanaan Struktur Gedung RSUD Banten Menggunakan Struktur Baja Komposit Dengan Sistem Eccentrically Braced Frame (EBF)

Halim, Muliady (2024) Modifikasi Perencanaan Struktur Gedung RSUD Banten Menggunakan Struktur Baja Komposit Dengan Sistem Eccentrically Braced Frame (EBF). Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 03111940000080-Undergraduate_Thesis.pdf] Text
03111940000080-Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 October 2026.

Download (30MB) | Request a copy

Abstract

Indonesia, sebagai negara dengan populasi keempat terbesar di dunia, menghadapi tantangan mendesak dalam menyediakan fasilitas kesehatan yang memadai. Meskipun pertumbuhan populasi Kota Serang mencatat peningkatan, jumlah rumah sakit umum yang hanya mencapai 7 menunjukkan ketidakseimbangan yang signifikan. Dengan rasio perbandingan 102.908 antara jumlah penduduk dan fasilitas kesehatan yang terbatas, diperlukan langkah-langkah strategis untuk memenuhi kebutuhan tersebut. Selain itu, Provinsi Banten terus menerima dampak gempa bumi, menyebabkan kerusakan pada fasilitas umum dan meningkatkan risiko korban jiwa. Oleh karena itu, proyek penelitian ini memiliki tujuan ganda: pertama, meningkatkan jumlah dan kualitas rumah sakit sebagai respons terhadap pertumbuhan populasi, dan kedua, membangun rumah sakit yang tahan gempa untuk mengurangi dampak negatif dari bencana alam. Tugas Akhir ini akan menggunakan metode modifikasi pada Rumah Sakit Umum Daerah (RSUD) Banten, yang awalnya berdiri setinggi 8 lantai. Melalui modifikasi, gedung ini direncanakan akan meningkat menjadi 20 lantai dengan menggunakan konstruksi struktur baja berbasis Eccentrically Braced Frame (EBF) dengan konsep struktur komposit. Fondasi akan dirancang untuk menanggung beban gravitasi dan gaya lateral dari gempa dan angin, sementara pemilihan RSUD Banten dilatarbelakangi oleh kapasitas ruangan yang memadai. Berdasarkan hasil analisis dan perancangan yang dilakukan didapatkan hasil perencanaan diantaranya berupa tebal pelat lantai 10 cm untuk ruang lainnya selain koridor dan 11 cm untuk koridor. Balok Induk dan Link Arah X menggunakan profil baja WF 600x300x12x20, Balok Induk dan Link Arah Y menggunakan profil baja WF 700x300x13x20. Kolom menggunakan CFT 500x500x25, CFT 800x800x35, dan CFT 900x900x40. Bresing menggunakan profil WF 350x350x12x19. Direncanakan panjang link menggunakan 80 cm untuk arah x dan 60 cm untuk arah Y, pondasi menggunakan Spun Pile dari WIKA dengan diameter D100 dengan kedalaman 17 meter dengan jumlah tiang 6 buah. dimensi poer, olom pedestal, dan sloof menggunakan secara berturut turut berupa 7 m x 4,5 m x 1 m untuk dimensi poer, 1,3 m x 1,3m untuk dimensi kolom pedestal, dan 400x600 untuk sloof
=====================================================================================================================================
Indonesia, as the fourth most populous country in the world, faces an urgent challenge in providing adequate healthcare facilities. Although the population growth of Serang City has increased, the number of public hospitals has only reached 7, indicating a significant imbalance. With a ratio of 102,908 between the population and limited healthcare facilities, strategic steps are needed to meet these needs. In addition, Banten Province continues to be affected by earthquakes, causing damage to public facilities and increasing the risk of loss of life. Therefore, this research project has a dual purpose: first, to increase the number and quality of hospitals in response to population growth, and second, to build earthquake-resistant hospitals to reduce the negative impacts of natural disasters. This Final Project will use a modification method on the Banten Regional General Hospital (RSUD), which originally stood 8 floors high. Through modification, this building is planned to increase to 20 floors using steel structure construction based on Eccentrically Braced Frame (EBF) with a composite structure concept. The foundation will be designed to withstand gravity loads and lateral forces from earthquakes and wind, while the selection of RSUD Banten is based on adequate room capacity. Based on the results of the analysis and design carried out, the planning results include a floor plate thickness of 10 cm for other rooms besides the corridor and 11 cm for the corridor. The Main Beam and X Direction Link use WF 600x300x12x20 steel profiles, the Main Beam and Y Direction Link use WF 700x300x13x20 steel profiles. Columns use CFT 500x500x25, CFT 800x800x35, and CFT 900x900x40. Bracing uses WF 350x350x12x19 profiles. The planned link length uses 80 cm for the x direction and 60 cm for the Y direction, the foundation uses Spun Pile from WIKA with a diameter of D100 with a depth of 17 meters with a total of 6 poles. The dimensions of the poer, pedestal column and sloof are respectively 7 m x 4.5 m x 1 m for the poer dimensions, 1.3 m x 1.3 m for the pedestal column dimensions and 400 x 600 for the sloof

Item Type: Thesis (Other)
Uncontrolled Keywords: Earthquake Resistant, Eccentrically Braced Frame (EBF) Steel Structure, Composite Steel-Concrete Structure
Subjects: T Technology > TA Engineering (General). Civil engineering (General) > TA658 Structural design
T Technology > TH Building construction > TH1095 Earthquakes and building
Divisions: Faculty of Civil, Planning, and Geo Engineering (CIVPLAN) > Civil Engineering > 22201-(S1) Undergraduate Thesis
Depositing User: Muliady Halim
Date Deposited: 01 Aug 2024 13:20
Last Modified: 17 Sep 2024 06:38
URI: http://repository.its.ac.id/id/eprint/109572