Khalisha, Rania Amanta (2024) Desain Modifikasi dan Analisis Penerapan Sistem Buckling Restrained Braced Frames (BRBF) dan Struktur Baja Komposit pada Gedung Tower 3 ITS Surabaya. Other thesis, Institut Teknologi Sepuluh Nopember.
Text
5012201010-Undergraduate_Thesis.pdf - Accepted Version Restricted to Registered users only until 1 October 2026. Download (24MB) | Request a copy |
Abstract
Pulau Jawa memiliki potensi gempa hingga mencapai maksimum magnitudo 8,8 akibat pengaruh Zona Megathrust pada sisi selatan Pulau Jawa (BMKG, 2019). Oleh karena itu, untuk mencegah kerusakan yang tidak diinginkan ketika bencana gempa bumi terjadi, struktur bangunan harus direncanakan sebaik mungkin agar tahan terhadap gempa. Salah satu jenis konstruksi baja yang dapat digunakan adalah Bresing Baja Tahan Tekuk atau Buckling Restrained Braced Frame (BRBF). Dalam tugas akhir ini struktur Gedung Tower 3 ITS yang berada di Kota Surabaya dan terdiri dari 12 lantai dengan sistem struktur beton bertulang dan dinding geser akan dimodifikasi dengan sistem struktur BRBF dengan konfigurasi inverted V-braced atau chevron. Penggunaan material baja dalam perencanaan struktur dipilih karena memiliki daktilitas dan kekuatan yang relatif tinggi. BRBF sendiri dinilai memiliki kekakuan lateral yang lebih baik daripada MRF dan dapat meningkatkan disipasi energi. Pada BRBF, bresing dapat memiliki kekuatan yang sama saat terjadi tarik dan tekan sehingga dapat mengurangi potensi terjadinya buckling. Analisis perencanaan dilakukan dengan menggunakan program bantu ETABS V21. Dari hasil analisis perencanaan yang sudah dilakukan diperoleh dimensi pelat dengan tebal 11 cm, dimensi balok induk terbesar adalah WF 600 x 300 x 12 x 20, dan dimensi kolom CFT terbesar adalah 800 x 800 x 32. Profil bresing terbesar menggunakan CoreBrace BRB dengan luas inti baja 12 in2. Direncanakan pondasi menggunakan spun pile diameter 60 cm dengan kedalaman 34 m. Dimensi pilecap terbesar adalah 4,2 m x 9,6 m, dimensi kolom pedestal terbesar adalah 1,1 m x 1,1 m dan dimensi sloof adalah 400 x 600 mm. Pada tugas akhir ini juga dilakukan komparasi antara struktur eksisting dengan struktur rencana. Beberapa hal yang dibandingkan antara lain berat struktur, periode getar alami struktur, gaya geser seismic, simpangan lantai, dan kebutuhan pondasi. Dari hasil perbandingan tersebut didapatkan bahwa berat struktur rencana adalah 40% lebih ringan dibandingkan struktur eksisting dan kebutuhan pondasinya adalah 55% lebih sedikit dibandingkan struktur eksisting.
========================================================================================================================
The island of Java has the potential for earthquakes reaching a maximum magnitude of 8.8 due to the influence of the Megathrust Zone on the southern side of Java Island (BMKG, 2019). Therefore, to prevent unwanted damage when earthquakes occur, building structures must be planned as best as possible to withstand earthquakes.. Buckling Restrained Braced Frame (BRBF) is one of those type of steel structures that can be used. In this final project, the structure of Tower 3 ITS located in Surabaya, consisting of 12 floors with a reinforced concrete structure and shear walls, will be modified with the Buckling Restrained Braced Frame (BRBF) structural system with an inverted V-braced or chevron configuration. The use of steel material in structural planning is chosen because it has relatively high ductility and strength. BRBF itself is considered to have better lateral stiffness than MRF and can increase energy dissipation. In BRBF, the braces can have the same strength when tensile and compressive so as to reduce the potential for buckling. The analysis is conducted using ETABS V21. From the analysis of the planning obtained results include the slab thickness is 11 cm, the largest main beam profile is 600 x 300 x 12 x 20, and the largest column profile is CFT 800 x 800 x 32. The largest bracing used is CoreBrace BRB with steel core area of 12 in2. The foundation is planned to use 60 cm spun pile in the depth of 34 m. The largest dimension of pilecap is 4,2 m x 9,6 m, the largest pedestal column is 1,1 m x 1,1 m, and the sloof dimension is 400 mm x 600 mm. This final project also includes a comparison between the existing structure and the planned structure. Several aspects compared include structure weight, natural period of vibration, seismic shear force, floor displacement, and foundation requirements. From this comparison, it is found that the planned structure is 40% lighter than the existing structure and requires 55% less foundation.
Item Type: | Thesis (Other) |
---|---|
Uncontrolled Keywords: | Struktur Baja, Tahan Gempa, Bresing Tahan Tekuk, Tower 3 ITS, Surabaya, Steel Structure, Earthquake Resistant, Buckling Restrained Braced Frame, ITS Tower 3 |
Subjects: | T Technology > TA Engineering (General). Civil engineering (General) > TA645 Structural analysis (Engineering) T Technology > TA Engineering (General). Civil engineering (General) > TA658 Structural design |
Divisions: | Faculty of Civil, Planning, and Geo Engineering (CIVPLAN) > Civil Engineering > 22201-(S1) Undergraduate Thesis |
Depositing User: | RANIA AMANTA KHALISHA |
Date Deposited: | 31 Jul 2024 06:50 |
Last Modified: | 31 Jul 2024 06:50 |
URI: | http://repository.its.ac.id/id/eprint/109645 |