Sistem Pengendalian Kualitas Limbah Cair Rumah Tangga Pada Waste Water Treatment Plant

Muhammad, Rasyid Ridha (2024) Sistem Pengendalian Kualitas Limbah Cair Rumah Tangga Pada Waste Water Treatment Plant. Diploma thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 2042201114-Undergraduate_Thesis.pdf] Text
2042201114-Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 October 2026.

Download (5MB) | Request a copy

Abstract

Sistem pengelolaan air limbah rumah tangga terlihat kurangnya perawatan dan pemeliharaan yang memadai, sehingga memberi dampak yang kurang baik bagi lingkungan maupun kesehatan. Untuk menjaga kadar air limbah rumah tangga diperlukan sistem pengendalian pada sistem pengelolaan air limbah. Fuzzy logic controller metode sugeno digunakan pada sistem pengendalian untuk memanipulasi kerja pompa dan solenoid valve sesuai dengan rentang nilai fuzzy untuk parameter pH, TDS, DO, dan gas NH3. Performa hasil yang didapatkan oleh fuzzy logic controller dapat menjaga kualitas limbah cair rumah tangga sesuai standar baku dengan nilai yang terlihat turun pada parameter pH, TDS, dan NH3 serta naik pada parameter DO hingga mencapai nilai standar yang telah digunakan. Pembacaan sensor yang digunakan pada plant juga memiliki nilai error pada parameter pH sebesar 3,238%, parameter TDS sebesar 0,245%, parameter DO sebesar 1,107%, dan parameter gas NH3 sebesar 25,467% ketika dibandingkan dengan validator dari masing-masing parameter tersebut.
========================================================================================================================
The household wastewater management system appears to lack adequate care and maintenance, resulting in a negative impact on the environment and health. To maintain household wastewater levels, a control system is needed in the wastewater management system. The Sugeno method fuzzy logic controller is used in the control system to manipulate the work of the pump and solenoid valve according to the fuzzy value range for the pH, TDS, DO and NH3 gas parameters. The performance results obtained by the fuzzy logic controller can maintain the quality of household liquid waste according to standard standards with values that appear to decrease in the pH, TDS and NH3 parameters and increase in the DO parameter until they reach the standard values that have been used. The sensor readings used in the plant also have an error value for the pH parameter of 3.238%, the TDS parameter of 0.245%, the DO parameter of 1.107%, and the NH3 gas parameter of 25.467% when compared with the validator for each of these parameters.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Air Limbah Rumah Tangga, Fuzzy Logic, pH, TDS, DO, NH3, Household Wastewater, Fuzzy Logic, pH, TDS, DO, NH3
Subjects: T Technology > TD Environmental technology. Sanitary engineering > TD433 Water treatment plants
Divisions: Faculty of Vocational > Instrumentation Engineering
Depositing User: Muhammad Rasyid Ridha
Date Deposited: 02 Aug 2024 05:49
Last Modified: 02 Aug 2024 05:49
URI: http://repository.its.ac.id/id/eprint/109946