Analisis Pendistribusian Tekanan Pada Jaringan Pipa Gas Rumah Tangga di PT PGAS Solution (Studi Kasus di Pacar Kembang IV, Surabaya)

Kusadi, Regina Cahya (2024) Analisis Pendistribusian Tekanan Pada Jaringan Pipa Gas Rumah Tangga di PT PGAS Solution (Studi Kasus di Pacar Kembang IV, Surabaya). Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 2039201039-Undergraduate_Thesis.pdf] Text
2039201039-Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 October 2026.

Download (5MB) | Request a copy

Abstract

Kebutuhan energi di Indonesia diproyeksikan akan mengalami peningkatan sebesar 5,4% pada tahun 2023, hal ini didorong oleh pertumbuhan ekonomi dan populasi. Peningkatan ini menantang Indonesia untuk memenuhi kebutuhan energi industri secara efisien. Konsumsi energi terbesar terjadi pada sektor industri dan rumah tangga, terutama gas alam. Sektor industri dan rumah tangga memiliki peranan yang sangat besar dalam peningkatan kebutuhan energi di Indonesia khususnya gas alam. Pada tahun 2008 pemerintah mulai merencanakan pembangunan jaringan gas oleh PT PGAS Solution. Pembangunan jaringan gas merupakan upaya pemerintah untuk mewujudkan ketahanan energi serta meningkatkan kesejahteraan masyarakat. Dalam instalsi perpipaannya jaringan gas ini terdapat beberapa aksesoris perpipaan yang beragam atau sering kita sebut fitting seperti elbow, equal tee dan endcap. Dalam penelitian proyek akhir ini dilakukan untuk menganalisis tekanan pada pendistribusian gas rumah tangga dari RS (Regulator Sektor) ke titik lokasi pelanggan terjauh di Pacar kembang IV, Surabaya. Tahapan pada penelitian proyek akhir ini adalah dengan melakukan perhitungan secara analitis dan numerik (Pipe Flow Expert). Persamaan yang digunakan untuk menghitung mayor losses pada penelitian ini adalah persamaan Weymouth. Hasil dari penelitian ini adalah P2 (tekanan akhir) secara analitis sebesar 0,2328 barg. Sedangkan secara numerik sebesar 0,2341 barg. Hasil ini sesuai dengan data Perusahaan sebesar 0,23 barg. Perbandingan antara perhitungan analitis dan numerik sebesar 0,558% dimana prosentase error ini berada pada batas yang diijinkan, yaitu < 2%. Sehingga, dapat disimpulkan bahwasanya tekanan akhir yang sampai pada pelanggan terjauh dapat terpenuhi (P2 di titik pelanggan terjauh > P yang dibutuhkan tiap rumah tangga, yaitu 0,03 barg).
========================================================================================================================
Indonesia's energy demand is projected to increase by 5,4% by 2023, driven by economic and population growth. This increase challenges Indonesia to meet industrial energy needs efficiently. The largest energy consumption occurs in the industrial and household sectors, especially natural gas. The industrial and household sectors have a very large role in increasing energy demand in Indonesia, especially natural gas. In 2008, the government began planning the construction of a gas network by PT PGAS Solution. The construction of the gas network is the government's effort to realize energy security and improve the welfare of the community. In the gas network piping installation, there are various piping accessories or what we often call fittings such as elbow, equal tee and endcap. In this final project research was carried out to analyze the pressure in the distribution of household gas from the RS (Sector Regulator) to the furthest customer location point in Pacar Kembang IV, Surabaya. The stages of this final project research are to perform analytical and numerical calculations (Pipe Flow Expert). The equation used to calculate the mayor losses in this study is the Weymouth equation. The results of this study are P2 (final pressure) analytically of 0,2328 barg. While numerically it is 0,2341 barg. This result is in accordance with the Company's data of 0,23 barg. The comparison between analytical and numerical calculations is 0,558% where the percentage error is within the allowable limit, which is <2%. So, it can be concluded that the final pressure that reaches the farthest customer can be fulfilled (P2 at the farthest customer point > P required for each household, which is 0,03 barg).

Item Type: Thesis (Other)
Uncontrolled Keywords: Jaringan gas rumah tangga, persamaan Weymouth, Pipe Flow Expert, Household gas networks, Weymouth equation, Pipe Flow Expert
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ935 Pipe--Fluid dynamics. Tubes--Fluid dynamics
Divisions: Faculty of Vocational > Mechanical Industrial Engineering (D4)
Depositing User: Regina Cahya Kusadi
Date Deposited: 03 Aug 2024 04:15
Last Modified: 03 Aug 2024 04:19
URI: http://repository.its.ac.id/id/eprint/111265

Actions (login required)

View Item View Item