Analisis Pengaruh Jarak Antar Plat Elektroda Pada Sistem Pengolahan Air Pdam Pada Metode Elektrokoagulasi

Khoir, Fiqih Adhimul (2024) Analisis Pengaruh Jarak Antar Plat Elektroda Pada Sistem Pengolahan Air Pdam Pada Metode Elektrokoagulasi. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 5001201118-Undergraduate_Thesis.pdf] Text
5001201118-Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 October 2026.

Download (10MB) | Request a copy

Abstract

Air merupakan senyawa kimia yang sangat penting bagi kehidupan manusia dan tidak akan bisa digantikan oleh senyawa lain. Penggunaan air yang sangat utama adalah sebagai air minum. Berdasarkan Peraturan Menteri Kesehatan Republik Indonesia Nomor 492/Menkes/PerIV/2010 terkait persyaratan kualitas air minum maka, dilakukan penelitian ini dengan tujuan untuk mengetahui nilai penurunan turbidity, kestabilan pH, dan pengaruh jarak antar elektroda pada proses elektrokoagulasi dan filtrasi. Proses elektrokoagulasi ini menggunakan plat aluminium dengan variasi jarak antar plat sebesar 2cm; 2,5cm; dan 3cm untuk mengetahui penurunan nilai kekeruhan dan kestabilan pH pada air PDAM. Didapatkan hasil penurunan untuk nilai kekeruhan sebesar 76,2% namun dengan waktu yang berbeda pada tiap variasi jaraknya. Dengan variasi jarak antar plat elektroda sebesar 2cm memiliki waktu yang paling cepat dari pada variasi lainnya. Untuk pH pada air masih stabil pada rentan 6,5-8,5 untuk semua variasi jarak antar plat.
============================================================================================================
Water is a chemical compound that is very important for human life and cannot be replaced by other compounds. The main use of water is as drinking water. Based on the Regulation of the Minister of Health of the Republic of Indonesia Number 492/Menkes/Per/IV/2010 related to drinking water quality requirements, this research was conducted with the aim of knowing the value of turbidity reduction, pH stability, and the effect of distance between electrodes on the electrocoagulation and filtration process. This electrocoagulation process uses aluminum plates with variations in the distance between plates of 2cm, 2.5cm, and 3cm to determine the decrease in turbidity value and pH stability in PDAM water. The results obtained for the turbidity value decreased by 76.2% but with different times for each distance variation. With a variation in the distance between electrode plates of 2cm has the fastest time than other variations. The pH of the water is still stable at 6.5-8.5 for all variations of the distance between the plates.

Item Type: Thesis (Other)
Uncontrolled Keywords: Electrocoagulation, pH, Turbidity, Elektrokoagulasi, Turbidity.
Subjects: Q Science > QC Physics
Divisions: Faculty of Science and Data Analytics (SCIENTICS) > Physics > 45201-(S1) Undergraduate Thesis
Depositing User: Fiqih Adhimul Khoir
Date Deposited: 18 Aug 2024 01:25
Last Modified: 18 Aug 2024 01:25
URI: http://repository.its.ac.id/id/eprint/111639

Actions (login required)

View Item View Item