Analisa Pengaruh Kinerja Heat Exchanger Shell and Tube Terhadap Produksi Desalination Plant Pada PLTGU Kapasitas 1500MW

Azhari, Ahmad Reza (2024) Analisa Pengaruh Kinerja Heat Exchanger Shell and Tube Terhadap Produksi Desalination Plant Pada PLTGU Kapasitas 1500MW. Diploma thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 2039201048-Undergraduate_Thesis for D4.pdf] Text
2039201048-Undergraduate_Thesis for D4.pdf - Accepted Version
Restricted to Repository staff only until 1 October 2026.

Download (4MB) | Request a copy

Abstract

Brine heater merupakan salah satu alat penukar panas dalam proses desalinasi air laut yang berfungsi untuk memanaskan air laut meggunakan uap (saturated) dari LP steam hingga mencapai temperatur tertentu (top brine temperature), di mana temperatur air keluaran brine heater dapat mempengaruhi proses penguapan pada evaporator. Brine heater merupakan alat penukar panas (heat exchanger) jenis shell and tube dengan tipe aliran crossflow yang kinerjanya dapat mempengaruhi performa dari Desalination Plant tersebut. Analisa ini bertujuan menunjukkan pengaruh kinerja brine heater terhadap performa Desalination Plant. Selain itu Semakin lama heat exchanger digunakan akan menyebabkan penurunan kinerja heat exchanger seperti besarnya laju perpindahan panas aktual efektivitas dan fouling factor. Oleh karena itu dilakukan analisis heat exchanger untuk mengetahui pengaruh performa, laju perpindahan panas actual. dan efektivitas heat exchanger terhadap produksi desalination Plant. Metode penelitian yang digunakan ini berupa pengamatan langsung, mencari data dan perhitungan performa brine heater, wawancara dan diskusi dengan pihak – pihak terkait serta menganalisis kemungkinan pengaruh kinerja brine heater terhadap performa dari Desalination Plant berdasarkan data. Hasil perhitungan dan analisa menunjukan pengaruh efektifitas kinerja brine heater terhadap performa Desalination Plant cukup signifikan yaitu rata-rata sebesar 68%. Nilai efektivitas dan performa. Desalination Plant menunjukkan penurunan yang diakibatkan oleh penumpukan kerak dan perbedaan beban unit PLTGU.==================================================================================================================Brine heater is one of the heat exchangers in the seawater desalination process that functions to heat seawater using steam (saturated) from LP steam to reach a certain temperature (top brine temperature), where the temperature of the brine heater output water can affect the evaporation process on the evaporator. Brine heater is a shell and tube type heat exchanger with crossflow type whose performance can affect the performance of the Desalination Plant. This analysis aims to show the effect of brine heater performance on Desalination Plant performance. In addition, the longer the heat exchanger is used, it will cause a decrease in heat exchanger performance such as the magnitude of the actual heat transfer rate, effectiveness, and fouling factor. Therefore, heat exchanger analysis is carried out to determine the effect of performance, actual heat transfer rate. and the effectiveness of heat exchangers on desalination plant production. The research method used is in the form of direct observation, looking for data and calculation of brine heater performance, interviews and discussions with related parties and analyzing the possible effect of brine heater performance on the performance of the Desalination Plant based on data. The results of calculations and analysis show that the effect of brine heater performance on the performance of the Desalination Plant is quite significant, which is an average of 68%. Value effectiveness and performance. The Desalination Plant shows a decrease caused by scale buildup and differences in PLTGU unit loads.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Brine Heater, Performa, Desalination Plant, Brine Heater, Performance, Desalination Plant
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ263 Heat exchangers
Divisions: Faculty of Vocational > Mechanical Industrial Engineering (D4)
Depositing User: Ahmad Reza Azhari
Date Deposited: 06 Aug 2024 07:21
Last Modified: 06 Aug 2024 07:21
URI: http://repository.its.ac.id/id/eprint/111640

Actions (login required)

View Item View Item