Alam, Rizki Faizal (2024) Studi Numerik Pengaruh Variasi Jumlah Sudu Impeller Terhadap Performa Pompa Slurry Sentrifugal Semi Open Impeller. Other thesis, Institut Teknologi Sepuluh Nopember.
Text
2039201054-undergraduate_Thesis for D4 Program.pdf - Accepted Version Restricted to Repository staff only until 1 October 2026. Download (6MB) | Request a copy |
Abstract
Pompa adalah peralatan mekanik yang memindahkan fluida cair dari tempat berenergi rendah ke tempat berenergi lebih tinggi melalui sistem perpipaan. Pompa sentrifugal adalah salah satu jenis pompa yang paling umum digunakan di dunia saat ini, dan banyak digunakan dalam industri, rumah tangga, dan bahkan di ruang angkasa. Nilai performa adalah indikator kualitas pompa sentrifugal. Head, daya, kapasitas, dan efisiensi adalah semua aspek kinerja pompa. Beberapa faktor memengaruhi kinerja pompa. Beberapa di antaranya adalah bentuk sudu, besar kecilnya sudut inlet dan outlet sudu, jarak antara casing dan impeller atau side clearance, dan jumlah sudu. Penelitian ini mengkaji pengaruh variasi jumlah sudu impeller terhadap performa pompa slurry sentrifugal dengan semi open impeller melalui studi numerik. Performa pompa ini sangat dipengaruhi oleh desain impeller, khususnya jumlah sudu yang digunakan.Tujuan penelitian ini adalah untuk memahami bagaimana perubahan jumlah sudu pada impeller mempengaruhi karakteristik aliran fluida dan efisiensi pompa. Metode penelitian yang digunakan adalah Computational Fluid Dynamics (CFD) untuk mensimulasikan aliran fluida dalam pompa dengan variasi jumlah sudu yang berbeda, yaitu 5, 6, 8, 9, 10, dan 12 sudu. Hasil pada penelitian ini menunjukkan bahwa modifikasi jumlah sudu dan membandingkan pengaruh fluida vikositas rendah dan tinggi terhadap performa pompa sentrifugal. Penggunaan viskositas berbeda akan mempengaruhi performa pompa sentrifugal. Dimana fluida air memiliki efisiensi lebih tinggi pada jumlah sudu 9 sebesar 65,19% daripada fluida slurry dengan nilai efisiensi 62% .Sedangkan Dengan peningkatan jumlah sudu, terjadi peningkatan head dan efisiensi pompa, namun dengan batas tertentu di mana penambahan jumlah sudu tidak lagi memberikan peningkatan signifikan atau bahkan menurunkan performa akibat peningkatan gesekan dan turbulensi aliran. Head tertinggi pada penggunaan fluida slurry dengan nilai 32,8 m pada kapasitas 108 m^3/h . Sedangkan saat menggunakan fluida Air, nilai head sebesar 32,3 m pada kapasitas 108 m^3/h . Sehingga didapat jumlah sudu yang optimal pada semi open impeller yaitu 9 sudu.
===========================================================
A pump is a mechanical device that transfers liquid fluids from a lower energy level to a higher energy level through a piping system. Centrifugal pumps are one of the most commonly used types of pumps in the world today, extensively used in industries, households, and even in space. Performance values are indicators of the quality of a centrifugal pump. Head, power, capacity, and efficiency are all aspects of pump performance. Several factors influence pump performance, including the blade shape, the inlet and outlet blade angles, the side clearance between the casing and impeller, and the number of blades. This research the impact of varying the number of impeller blades on the performance of a centrifugal slurry pump with a semi-open impeller through numerical analysis. The performance of this pump is heavily influenced by the impeller design, particularly the number of blades used. The objective of this research is to understand how changes in the number of blades on the impeller affect fluid flow characteristics and pump efficiency. The research method used is Computational Fluid Dynamics (CFD) to simulate fluid flow in the pump with different numbers of blades, namely 5, 6, 8, 9, 10, and 12 blades. The results of this study show that modifying the number of blades and comparing the impact of fluids with low and high viscosity on the performance of the centrifugal pump. The use of different viscosities will affect the performance of the centrifugal pump. Water, as a fluid, has a higher efficiency at 9 blades with 65.19% compared to slurry fluid with an efficiency value of 62%. As the number of blades increases, there is an increase in head and pump efficiency, but only up to a certain point where adding more blades does not provide significant improvement or may even decrease performance due to increased friction and flow turbulence. The highest head for slurry fluid was 32.8 m at a capacity of 108 m³/h, whereas for water, the head was 32.3 m at the same capacity. Therefore, the optimal number of blades for a semi-open impeller is 9 blades.
Item Type: | Thesis (Other) |
---|---|
Uncontrolled Keywords: | Pompa Slurry Sentrifugal, Impeller, Jumlah Sudu, Head Pompa, Efisiensi Pompa, Computational Fluid Dynamics (CFD).Centrifugal Slurry Pump, Impeller, Blade Number, Pump Head, Pump Efficiency, Computational Fluid Dynamics (CFD). |
Subjects: | T Technology > T Technology (General) T Technology > TJ Mechanical engineering and machinery > TJ935 Pipe--Fluid dynamics. Tubes--Fluid dynamics |
Divisions: | Faculty of Vocational > Mechanical Industrial Engineering (D4) |