Sistem Pengujian dan Kalibrasi Sensor Flow pada Aliran Cairan Dialisat Mesin Hemodialisis

Valerina, Anida Maura (2024) Sistem Pengujian dan Kalibrasi Sensor Flow pada Aliran Cairan Dialisat Mesin Hemodialisis. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 5023201040-Undergraduate_Thesis.pdf] Text
5023201040-Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 October 2026.

Download (5MB) | Request a copy

Abstract

Mesin hemodialisis terdiri dari instrumentasi yang kompleks, sehingga mesin harus memiliki akurasi yang baik sebelum layak digunakan untuk pasien cuci darah. Salah satu bagian yang penting untuk meningkatkan akurasi yaitu kalibrasi sensor flow untuk mendeteksi adanya aliran cairan dialisat. Flow atau laju aliran cairan dialisat diperoleh dari volume (mililiter) yang dibutuhkan selama cairan dialisat dialirkan menuju dialiser dalam waktu satu menit. Rentang nilai laju aliran pada mesin hemodialisis berada pada 500-800 ml/menit tergantung kebutuhan pasien. Penelitian sebelumnya melakukan kalibrasi sensor flow menggunakan filter sehingga memperoleh eror 2,5%. Pada penelitian saat ini, pengujian sensor flow dialisat menunjukkan hasil eror 2,95% dan akurasi 97%. Hal ini menunjukkan terdapat penurunan 0,45% dari penelitian sebelumnya yang sudah melakukan kalibrasi sensor flow. Namun, kalibrasi dan pengujian yang dilakukan penelitian sebelumnya dilakukan pada sistem yang berbeda di luar mesin HD, sehingga pengondisiannya berbeda dan pembacaan sensor flow erornya lebih kecil. Sedangkan pada penelitian ini, kalibrasi dan pengujian sensor flow dilakukan di mesin HD sehingga memungkinan pembacaan yang erornya lebih besar akibat mesin HD yang terlalu banyak beban. Berdasarkan pembacaan flow rate dialisat pada pengujian pertama dengan darah, flow rate yang diperoleh dengan kontrol PWM yaitu 238,01 ml/menit dan 237,09 ml/menit, laju aliran dialisat tersebut berada dibawah rentang flow dialisat pada umumnya. Sedangkan pada pengujian kedua, flow rate dialisat pada masing-masing pengujian adalah 456,61 ml/menit, 608,62 ml/menit, dan 502,49 ml/menit. Hal ini menunjukkan bahwa kontrol pompa dengan kontroler dapat menstabilkan flow rate dialisat dalam rentang 500 – 800 ml/menit.
=================================================================================================================================
Hemodialysis machines consist of complex instrumentation, so they must have good accuracy before they can be used for dialysis patients. One subsystem that is important to improve accuracy is the calibration of the flow sensor to detect the flow of dialysate fluid. Flow or dialysate fluid flow rate obtained from the volume (milliliters) required for dialysate fluid to flow into the dialyser within one minute. The range of flow rate values on hemodialysis machines is 500-800 ml/min depending on the patient's needs. Previous research calibrated the flow sensor using a filter to obtain an error of 2.5%. In the current study, dialysate flow sensor testing showed an error of 2.95% and an accuracy of 97%. This shows a decrease of 0.45% from previous research that has calibrated the flow sensor. However, the calibration and testing carried out by previous research was carried out on a different system outside the HD machine, so the conditioning was different and the flow sensor reading error was smaller. Whereas in this study, calibration and testing of the flow sensor were carried out on the HD machine so that it is possible that the error reading is greater due to the HD machine being overloaded. Based on the dialysate flow rate reading in the first test with blood, the flow rate obtained with PWM control is 238.01 ml/min and 237.09 ml/min, the dialysate flow rate is below the dialysate flow range in general. While in the second test, the dialysate flow rate in each test was 456.61 ml/min, 608.62 ml/min, and 502.49 ml/min. This shows that the pump control with controller can stabilize the dialysate flow rate in the range of 500 - 800 ml/min.

Item Type: Thesis (Other)
Uncontrolled Keywords: dialisat, flow, hemodialisis, kalibrasi, laju aliran, sensor, pengujian, dialysate, hemodialysis, calibration, flow rate, testing
Subjects: Q Science > QA Mathematics > QA278.2 Regression Analysis. Logistic regression
Divisions: Faculty of Intelligent Electrical and Informatics Technology (ELECTICS) > Biomedical Engineering > 11410-(S1) Undergraduate Thesis
Depositing User: Anida Maura Valerina
Date Deposited: 27 Aug 2024 02:22
Last Modified: 27 Aug 2024 02:22
URI: http://repository.its.ac.id/id/eprint/112053

Actions (login required)

View Item View Item