Uji Efektivitas Jumlah Pasang Plat Kapasitor Pada Standing Water Detector

Rachmanda, Mochammad Aditya (2024) Uji Efektivitas Jumlah Pasang Plat Kapasitor Pada Standing Water Detector. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 5001201072-Undergraduate_Thesis.pdf] Text
5001201072-Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 October 2026.

Download (4MB) | Request a copy

Abstract

Penelitian ini mengkaji jumlah pasang plat kapasitor yang ada pada standing water detector. Tujuan dari penelitian ini adalah untuk mengetahui variasi jumlah pasang plat kapasitor yang lebih efektif kepresisiannya dan keakuratannya untuk pengukuran ketinggian air. Metode yang digunakan adalah metode kuantitatif dimana peneliti mengambil data secara langsung pada purwarupa rancang bangun standing water detector dengan membandingkan antara 1 pasang plat kapasitor, 2 pasang plat kapasitor, 3 pasang plat kapasitor, dan 4 pasang plat kapasitor. Dengan menggunakan metode tersebut, didapatkan data berupa ketinggian air dari tiap pengukuran pasang plat kapasitor beserta perbandingan ukuran real-nya dengan menggunakan penggaris. Data yang didapatkan berupa Relative Standard Deviation (RSD) yang merupakan representatif kepresisian dengan variasi terbaik adalah pada 3 pasang plat kapasitor dengan nilai RSD 0,5%, Selain itu nilai akurasi didapat dari persen eror terkecil yang menjadi toleransi dari pengukuran yang mana pada variasi 2 pasang plat kapasitor adalah yang terbaik dengan nilai toleransi ±9%. Dari penelitian ini diharapkan dapat menjadi evaluasi untuk dijadikan acuan perbaikan dan pengembangan sistem standing water detector.
============================================================================================
This research examines the number of pairs of capacitor plates in the standing water detector. The purpose of this research is to determine variations pair numbers of capacitor plates that are more effective in their precision and accuracy for measuring water level. The method that used is a quantitative method where researchers collect data directly on the prototype of the standing water detector design by comparing between 1 pair of capacitor plates, 2 pairs of capacitor plates, 3 pairs of capacitor plates, and 4 pairs of capacitor plates. By using this method, data is obtained in the form of water levels from each measurement of pairs of capacitor plates along with a comparison of their true measurement using a ruler. The obtained data is in the form of Relative Standard Deviation (RSD) which is a representative of precision with the best variation being in 3 pairs of capacitor plates with an RSD value of 0.5%. Moreover, the accuracy value is obtained from the smallest percent error which is the measurement tolerance at 2 pairs of capacitor plates is the best with a tolerance value of ±9%. This research hoped that can be used as an evaluation or used as a reference for improvement and development of the standing water detector system.

Item Type: Thesis (Other)
Uncontrolled Keywords: Dielectric, Error Factor, Hydroplanning, Relative Standard Deviation (RSD), Standard Deviation, Parallel Plate Capacitor Sensor, Standing Water Detector, Water Level Sensor. Dielektrik, Faktor Error, Hydroplanning, Relative Standard Deviation (RSD), Standar Deviasi, Sensor Kapasitor Plat Sejajar, Sensor Ketinggian Air, Standing Water Detector.
Subjects: Q Science
Q Science > QC Physics
Q Science > QC Physics > QC1 Dielectrics
Q Science > QC Physics > QC100.5 Measuring instruments (General)
Q Science > QC Physics > QC271.8.C3 Calibration
Q Science > QC Physics > QC585 Dielectrics
Q Science > QC Physics > QC925 Rain and rainfall
Divisions: Faculty of Science and Data Analytics (SCIENTICS) > Physics > 45201-(S1) Undergraduate Thesis
Depositing User: Mochammad Aditya Rachmanda
Date Deposited: 12 Aug 2024 12:57
Last Modified: 12 Aug 2024 12:57
URI: http://repository.its.ac.id/id/eprint/113833

Actions (login required)

View Item View Item