Air merupakan salah satu elemen yang penting bagi makhluk hidup. Jumlah total air yang ada di bumi tetap konstan berkat adanya siklus hidrologi yang terus berlangsung. Namun, hal tersebut sedikit berbeda dengan kondisi air bersih yang tersedia. Kebutuhan air bersih selalu meningkat tiap waktu seiring bertambahnya jumlah populasi makhluk hidup yang ada. Kebutuhan akan air bersih harus terpenuhi bagi setiap makhluk hidup, oleh karena itu dibutuhkan metode pengolahan air. Salah satu metode pengolahan air adalah metode elektrokaogulasi. Elektrokoagulasi merupakan metode pengolahan air yang menggunakan prinsip elektrokimia. Metode tersebut dapat dikombinasikan dengan filtrasi agar hasil pemurnian air dapat lebih maksimal. Pada penelitian kali ini dibuat sistem pengolahan air menggunakan metode elektrokoagulasi untuk mengolah air PDAM menjadi air siap minum. Sistem pengolahan air dapat digunakan secara otomatis sehingga lebih mudah dalam penggunaannya. Sistem ini dibuat menggunakan Arduino Uno R3, water level sensor sebagai pendeteksi ketinggian air, DFROBOT SEN0189 sebagai pendeteksi kekeruhan air, PH4502C sebagai sensor pH. Proses ini dilakukan dengan metode elektrokoagulasi dan filtrasi secara terus menerus hingga sesuai dengan kebijakan terkait air minum. Pada penelitian kali ini proses elektrokoagulasi dapat berjalan secara optimal dengan menggunakan 10 buah plat elektroda. Nilai kekeruhan mengalami penurunan hingga 78,8% dengan nilai kekeruhan awal 7,905 NTU dan nilai kekeruhan akhir 1,675 NTU. Pada pengukuran tersebut didapatkan nilai pH yang stabil pada rentang 6,5 hingga 8,5.
=================================================================================================================================
Water is one of the essential elements for living beings. The total amount of water on Earth remains constant due to the ongoing hydrological cycle. However, this is slightly different from the condition of available clean water. The need for clean water continues to increase over time as the population of living beings grows. The need for clean water must be met for every living being, hence the need for water treatment methods. One such method is electrocoagulation. Electrocoagulation is a water treatment method that uses electrochemical principles. In this study, a water treatment system was developed using the electrocoagulation method to process PDAM water into drinking water. The water treatment system can be used automatically, making it easier to use. This system was created using Arduino Uno R3, a water level sensor to detect water height, DFROBOT SEN0189 as a turbidity sensor, and PH4502C as a pH sensor. This process is carried out through continuous electrocoagulation and filtration until it meets the standards for drinking water. In this study, the electrocoagulation process can operate optimally using 10 electrode plates. The turbidity value decreased by 78.8%, with an initial turbidity value of 7.905 NTU and a final turbidity value of 1.675 NTU. The pH measurement remained stable in the range of 6.5 to 8.5.

Item Type: Thesis (Other)
Uncontrolled Keywords: Air, Elektrokoagulasi, Elektroda, Kekeruhan, pH, Electrocoagulation, Electrode, pH, Turbidity, Water
Subjects: Q Science > QC Physics > QC100.5 Measuring instruments (General)
Q Science > QC Physics > QC173.4.C63 Composite materials
Q Science > QC Physics > QC610.3 Electric conductivity
Divisions: Faculty of Science and Data Analytics (SCIENTICS) > Physics > 45201-(S1) Undergraduate Thesis