Evaluasi Pengaruh Frekuensi B-Mode Ultrasound dan Kedalaman Lesi pada Kualitas Citra In-House Phantom untuk Jaminan Mutu dan Kontrol Kualitas Ultrasonografi

Hanifah, Zhafira Rakhma (2024) Evaluasi Pengaruh Frekuensi B-Mode Ultrasound dan Kedalaman Lesi pada Kualitas Citra In-House Phantom untuk Jaminan Mutu dan Kontrol Kualitas Ultrasonografi. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 5001201100-Undergraduate_Thesis.pdf] Text
5001201100-Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only

Download (2MB) | Request a copy

Abstract

Ultrasonografi merupakan teknik pencitraan medis dengan menggunakan gelombang suara dengan frekuensi yang tinggi untuk menghasilkan citra gambar internal dari tubuh manusia yang dibutuhkan dalam kedokteran diagnostik untuk mendeteksi dan mendiagnosis berbagai kondisi medis. Dalam pelaksanaannya, dibutuhkan fantom sebagai alat pengganti jaringan tubuh yang digunakan untuk menguji kualitas gambar dan performa sistem ultrasonografi. Penelitian ini bertujuan untuk membuat in-house ultrasound phantom Sun Nuclear model 040GSE, mengevaluasi kualitas citra (uniformity, SNR, CNR) dari in-house ultrasound phantom berdasarkan frekuensi untuk jaminan mutu dan kontrol kualitas dan mengevaluasi kemampuan kepenggunaan kembali (repeatability) dari in-house ultrasound phantom yang telah dibuat. Teknik yang digunakan adalah citra B-mode ultrasound dengan transduser linear array probe dengan frekuensi 8 MHz, 10 MHz, dan 12 MHz. Fantom yang dibuat berbahan dasar PVC 7% dengan penambahan dioctyl terephthalate plasticizer (DOP) 83% dan gliserin 10%. Hasil pengujian didapatkan bahwa kedalaman lesi tidak terlalu berpengaruh pada kualitas citra dengan parameter CNR dikarenakan tidak adanya perbedaan nilai CNR yang signifikan diantara kedalaman 1 sampai 3 cm. Pada keseragaman citra, frekuensi 8 MHz menunjukkan nilai keseragaman citra yang lebih seragam dibanding dengan frekuensi 10 dan 12 MHz. Pada SNR, frekuensi 10 dan 12 MHz cenderung lebih baik digunakan daripada frekuensi 8 MHz. Pada CNR, frekuensi 12 MHz lebih baik untuk menilai kontras antara lesi dan latar belakang seiring dengan kedalaman lesi. Nilai SNR dan CNR cukup stabil dengan diukur dari waktu ke waktu mengindikasikan bahwa in-house phantom dapat digunakan dengan layak untuk jaminan mutu dan kontrol kualitas ultrasonografi.
======================================================================================================================================
Ultrasonography is a medical imaging technique that uses high-frequency sound waves to produce internal images of the human body, which are needed in diagnostic medicine to detect and diagnose various medical conditions. In its implementation, a phantom is required as a substitute for the body tissue used to test the image quality and performance of the ultrasound system. This study aims to create an in-house ultrasound phantom Sun Nuclear model 040GSE, evaluate the image quality (uniformity, SNR, and CNR) of the in-house ultrasound phantom based on frequency for quality assurance and quality control, and evaluate the reusability of the in-house ultrasound phantom that has been created. B-mode ultrasound imaging with a linear array probe transducer with frequencies of 8 MHz, 10 MHz, and 12 MHz was used. The phantom was made of 7% PVC with 83% dioctyl terephthalate plasticizer (DOP) and 10% glycerin. The test results showed that the depth of the lesion did not significantly affect the image quality with the CNR parameter, because there was no significant difference in CNR values between depths of 1–3 cm. In terms of image uniformity, the frequency of 8 MHz showed a more uniform image uniformity value than the frequencies of 10 and 12 MHz. For the SNR, the frequencies of 10 and 12 MHz tended to be better used than the frequency of 8 MHz. In CNR, a frequency of 12 MHz was better for assessing the contrast between the lesion and the background, along with the depth of the lesion. The SNR and CNR values were quite stable when measured over time, indicating that the in-house phantom can be used for the quality assurance and quality control of ultrasonography.

Item Type: Thesis (Other)
Uncontrolled Keywords: Frekuensi, Jaminan Mutu, Kontrol Kualitas, Phantom Ultrasound, Repeatability, Frequency, Quality Assurance, Quality Control, Phantom Ultrasound, Repeatability
Subjects: Q Science > QC Physics > QC795.5 Radioactivity and radioactive Instruments and apparatus (General)
R Medicine > R Medicine (General) > R856.2 Medical instruments and apparatus.
R Medicine > R Medicine (General) > R857.M3 Biomedical materials. Biomedical materials--Testing.
R Medicine > RC Internal medicine > RC78.7.U4 Ultrasonic imaging.
Divisions: Faculty of Science and Data Analytics (SCIENTICS) > Physics > 45201-(S1) Undergraduate Thesis
Depositing User: Zhafira Rakhma Hanifah
Date Deposited: 12 Aug 2024 05:26
Last Modified: 06 Jan 2026 08:15
URI: http://repository.its.ac.id/id/eprint/114489

Actions (login required)

View Item View Item