Sistem Kontrol Otomatis Level Air Pada Tandon Dengan Safety Pump Berbasis Mikrokontroler Arduino

Putri, Vellina Ayu (2024) Sistem Kontrol Otomatis Level Air Pada Tandon Dengan Safety Pump Berbasis Mikrokontroler Arduino. Diploma thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 2042201082-Undergraduate_Thesis.pdf] Text
2042201082-Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 October 2026.

Download (3MB) | Request a copy

Abstract

Pemanasan pada pompa air sering terjadi dalam pemakaian rumah tangga dan dapat disebabkan oleh beberapa faktor. Salah satu faktor umum adalah operasi dry-run, di mana pompa beroperasi tanpa air yang cukup atau tanpa air sama sekali, mengakibatkan motor cepat panas karena tidak ada pendinginan yang memadai. Selain itu, sumbatan pada saluran masuk dan keluar pompa memaksa motor bekerja lebih keras, meningkatkan beban dan suhu motor. Fluktuasi tegangan listrik yang tidak stabil juga menyebabkan motor bekerja tidak efisien, menghasilkan lebih banyak panas. Pemanasan ini dapat menyebabkan kerusakan serius pada komponen internal pompa, bahkan menyebabkan kegagalan total jika tidak segera diatasi. Untuk mengatasi masalah ini, penelitian ini merancang sistem safety pump menggunakan Thermal Overload Relay (TOR). Sistem ini bekerja dengan memantau suhu motor dan memutus aliran listrik jika suhu melebihi batas aman. TOR dipasang pada rangkaian listrik pompa dan secara konstan mengukur arus yang mengalir ke motor. Jika arus melebihi nilai yang telah ditentukan, TOR akan memutus sirkuit, sehingga mencegah motor dari overheating dan kerusakan lebih lanjut. Komponen utama yang digunakan dalam sistem ini meliputi TOR, sensor ultrasonik, relay, dan mikrokontroler Arduino Mega2560. TOR adalah komponen utama yang bertugas memutus aliran listrik ketika terjadi overheat. Konfigurasi safety pump pada pengisian tandon air melibatkan kontrol level otomatis yang dilengkapi dengan sistem safety pump ini. Ketika level air di tandon mencapai setpoint yang telah ditentukan yaitu batas bawah 35cm pompa menyala dan pada batas atas 60cm pompa mati. Serta pada percobaan kelebihan arus listrik pada pompa yang mencapai 1,7A TOR mampu mendeteksi adanya kelebihan arus dan memutuskan kontak pompa. Hal tersebut membuktikan bahwa sistem telah berjalan dengan baik dan sesuai dengan sistem yang telah dirancang.
==============================================================================================================================
Heating of water pumps is common in domestic use and can be caused by several factors. One common factor is dry-run operation, where the pump operates without sufficient water or no water at all, resulting in the motor heating up quickly as there is no adequate cooling. In addition, blockages at the pump inlet and outlet force the motor to work harder, increasing motor load and temperature. Unstable electrical voltage fluctuations also cause the motor to work inefficiently, generating more heat. This heating can cause serious damage to the pump's internal components, even leading to complete failure if not addressed immediately. To solve this problem, this research designs a safety pump system using a Thermal Overload Relay (TOR). The system works by monitoring the temperature of the motor and cutting off power if the temperature exceeds safe limits. The TOR is installed on the pump's electrical circuit and constantly measures the current flowing into the motor. If the current exceeds a predetermined value, the TOR will cut off the circuit, thus preventing the motor from overheating and further damage. The main components used in this system include the TOR, ultrasonic sensor, relay, and Arduino Mega2560 microcontroller. TOR is the main component in charge of cutting off electricity when overheating occurs. The safety pump configuration on the water reservoir filling involves automatic level control equipped with this safety pump system. When the water level in the reservoir reaches a predetermined setpoint, namely the lower limit of 35cm the pump turns on and at the upper limit of 60cm the pump turns off. As well as in the experiment of excess electric current in the pump which reached 1.7A TOR was able to detect the excess current and disconnect the pump contact. This proves that the system has run well and in accordance with the system that has been designed.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Tandon air, Level Air, Safety Pump, Thermal Overload Relay, Reservoir, Water Level
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK5103.8 Switching systems
Divisions: Faculty of Vocational > Instrumentation Engineering
Depositing User: Vellina Ayu Putri
Date Deposited: 22 Aug 2024 04:34
Last Modified: 22 Aug 2024 04:34
URI: http://repository.its.ac.id/id/eprint/114501

Actions (login required)

View Item View Item