Pemantauan daya dan beban pada suatu sistem sangat diperlukan untuk memantau daya dan menjaga sistem terus berjalan dengan optimal. Penelitian ini menambahkan suatu sistem monitoring deteksi dan pantau pada sistem Standing Water Detector (SWD) yang terdapat pada laboratorium terbuka lantai 2 Fisika ITS. SWD sendiri adalah sebuah sensor untuk mengukur ketinggian air menggunakan prinsip kapasitansi. Tujuan penelitian ini adalah untuk memantau dan mendiagnosa kerusakan yang terjadi pada sistem SWD secara realtime serta untuk menjaga sistem tersebut agar terus bekerja secara optimal. Metode yang digunakan yaitu dengan menambahkan sensor tegangan dan sensor arus untuk memantau daya pada PLTS, aki, dan antena. Selain itu, sensor arus INA219 dipasang untuk mendeteksi arus yang masuk pada modul sensor SWD, guna memeriksa apakah sistem mengalami kerusakan atau tidak. Hasil tegangan dan arus setelah dilakukan kalibrasi menunjukkan data dan perhitungan error menunjukkan hasil grafik yang linear dengan kalibrator dan dengan hasil eror yang kecil. Dari hasil perhitungan error dapat dikatakan bahwa sensor tegangan dan sensor arus yang digunakan mendapatkan hasil eror dibawah 1% sehingga memiliki tingkat presisi yang tinggi dan sangat mendekati nilai kalibrator, sehingga sensor ini dapat diaplikasikan untuk memonitoring dan mendeteksi kerusakan pada sistem SWD. Sensor tegangan dan arus akan mendeteksi kerusakan pada konektor SWD kemudian mengirimkan ke database server melalui jaringan wifi agar dilakukan perbaikan secepatnya agar terhindar dari kerusakan sistem yang lebih parah.

============================================================

Monitoring power and load in a system is crucial to ensure optimal operation. This research adds a monitoring and detection system to the Standing Water Detector (SWD) system located in the open laboratory on the 2nd floor of the Physics Department at ITS. SWD is a sensor that measures water level using the principle of capacitance. The goal of this research is to monitor and diagnose real-time damage to the SWD system and to ensure the system continues to operate optimally. The method used involves adding voltage and current sensors to monitor power in the PV system, battery, and antenna. Additionally, an INA219 current sensor is installed to detect the current entering the SWD sensor module to check for potential system malfunctions. After calibration, the voltage and current results show data and error calculations that present a linear graph with the calibrator and with minimal error. The error calculations indicate that the voltage and current sensors used have an error rate below 1%, which implies high precision and very close alignment with the calibrator values. Therefore, these sensors can be applied to monitor and detect malfunctions in the SWD system. The voltage and current sensors will detect damage to the SWD connectors and then send this information to a database server via Wi-Fi for prompt repairs to prevent further system damage.

Item Type: Thesis (Other)
Uncontrolled Keywords: Current Sensor, Detection System, Monitoring System, Standing Water Detector, Voltage Sensor, Sensor Arus, Sensor Tegangan, Sistem Deteksi, Sistem Monitoring, Standing Water Detector
Subjects: Q Science > QC Physics > QC100.5 Measuring instruments (General)
Q Science > QC Physics > QC271.8.C3 Calibration
Divisions: Faculty of Science and Data Analytics (SCIENTICS) > Physics > 45201-(S1) Undergraduate Thesis
Depositing User: Muhammad Alfreda Yoga Nugraha
Date Deposited: 13 Aug 2024 06:46
Last Modified: 13 Aug 2024 06:46
URI: http://repository.its.ac.id/id/eprint/115198

Actions (login required)

View Item View Item