Analisis Koordinasi Proteksi Penyulang Kuta, Novotel, dan Teluk Awang Dengan Incoming Trafo dan Pengaruhnya Terhadap Keandalan Distribusi Zero Down Time Sirkuit Mandalika

Alam, Muhammad Syaiful (2024) Analisis Koordinasi Proteksi Penyulang Kuta, Novotel, dan Teluk Awang Dengan Incoming Trafo dan Pengaruhnya Terhadap Keandalan Distribusi Zero Down Time Sirkuit Mandalika. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 5022201051-Undergraduate_Thesis.pdf] Text
5022201051-Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 October 2026.

Download (3MB) | Request a copy

Abstract

Sirkuit Mandalika merupakan tempat diselengarakannya gelaran ajang balap bertaraf internasional contohnya MotoGP. Dalam menunjang pagelaran acara yang diselengarakan di Sirkuit Mandalika maka diperlukan suplai listrik yang andal agar acara dapat berjalan tanpa kendala. Pihak PT PLN (Persero) Selaku pihak penyedia kelistrikan sirkuit mandalika merancang sebuah sistem Zero Down Time (ZDT) pada jaringan distribusi kawasan Sirkuit Mandalika. Sistem Zero Down Time atau dikenal juga dengan sistem jaringan listrik tanpa padam merupakan sistem dengan keadalan tinggi yang biasanya diterapkan pada kawasan VIP atau kawasan yang membutuhkan layanan listrik tanpa padam. Untuk memenuhi keandalan tinggi dari sistem ZDT selain dilihat dari konfigurasi jaringannya, koordinasi proteksi rele pengaman Overcurrent Relay (OCR) dan Ground Faulth Relay (GFR) sistem juga menjadi faktor yang memiliki andil besar dalam menjaga keandalan Kawasan Distribusi Sirkuit Mandalika. Dengan adanya 2 penyulang pararel Mandalika 1 dan Mandalika 2 yang terhubung dengan bus yang terkoneksi dengan 3 penyulang lainnya yaitu penyulang kuta, novotel dan teluk awang maka apabila terdapat gangguan yang berasal dari 3 penyulang tersebut apabila tidak diamankan maka dapat menggangu sistem distribusi Sirkuit Mandalika. Selain itu koordinasi proteksi antar rele proteksi yang berada pada incoming trafo GI kuta dengan masing-masing penyulang harus dipastikan bekerja sesuai dengan semestinya, demi mencegah kesalahan koordinasi trip. Pada sistem ini selain menggunakan grid dari PLN apabila terdapat gangguan yang menyebabkan suplai dari semua penyulang terputus maka terdapat suplai listik terakhir yang berasal dari genset dan dipasang UPS untuk mencegah kedip tegangan ketika dilakukan manuver beban. Dari hasil penelitian di usulkan perubahan jenis kurva dari standart inverse menjadi very inverse pada relay Bay trafo dan untuk kapasitas UPS ditentukan sesuai dengan pertimbangan beban dan manuver beban ketika terjadi gangguan.
==================================================================================================================================
The Mandalika Circuit is a venue for hosting international racing events such as MotoGP. To support these events, it is crucial to have a reliable power supply to ensure the event runs smoothly without interruptions. PT PLN (Persero), as the electricity provider for the Mandalika Circuit, has designed a Zero Down Time (ZDT) system for the distribution network in the Mandalika Circuit area. The Zero Down Time system, also known as an uninterrupted power supply system, is a highly reliable system typically implemented in VIP areas or locations requiring uninterrupted power services. To achieve high reliability of the ZDT system, in addition to the network configuration, the coordination of protection relays such as the Overcurrent Relay (OCR) and Ground Fault Relay (GFR) also plays a significant role in maintaining the reliability of the Mandalika Circuit Distribution Area. With the presence of two parallel feeders, Mandalika 1 and Mandalika 2, connected to a bus that is also connected to three other feeders (Kuta, Novotel, and Teluk Awang), any disturbance originating from these three feeders, if not secured, could affect the distribution system of the Mandalika Circuit. Furthermore, the coordination of protection between the incoming transformer relay at the Kuta substation and each feeder must be ensured to operate correctly to prevent trip coordination errors. In this system, apart from using the PLN grid, if there is a disturbance causing the supply from all feeders to be cut off, there is a backup power supply from generators, and a UPS is installed to prevent voltage dips during load maneuvers. The study proposes changing the curve type from standard inverse to very inverse on the transformer bay relay and determining the UPS capacity based on load considerations and load maneuvers during disturbances.

Item Type: Thesis (Other)
Uncontrolled Keywords: ZDT, OCR, GFR, Protection Coordination, Reliability, and UPS, ZDT, OCR, GFR, Koordinasi Proteksi, Keandalan, dan UPS.
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK2861 Electric relays. Protective relays--Security measures.
Divisions: Faculty of Intelligent Electrical and Informatics Technology (ELECTICS) > Electrical Engineering > 20201-(S1) Undergraduate Thesis
Depositing User: Muhammad Syaiful Alam
Date Deposited: 14 Aug 2024 02:13
Last Modified: 15 Aug 2024 03:37
URI: http://repository.its.ac.id/id/eprint/115387

Actions (login required)

View Item View Item