Evaluasi Safety Integrity Level Pada Reactor Unit 101 Residual Fluid Catalytic Cracking Berbasis Fuzzy-Layer of Protection Analysis (FLOPA)

Ramadhan, Dimas Rizki M (2022) Evaluasi Safety Integrity Level Pada Reactor Unit 101 Residual Fluid Catalytic Cracking Berbasis Fuzzy-Layer of Protection Analysis (FLOPA). Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 02311840000119-Undergraduate_Thesis.pdf] Text
02311840000119-Undergraduate_Thesis.pdf - Accepted Version

Download (3MB)

Abstract

Minyak menjadi sektor penting dalam perekonomian karena sektor ini memberi kontribusi yang masih cukup signifikan terhadap PDB, hingga pendapatan pemerintah. Salah satu perusahaan BUMN yang mengolah perminyakan yakni pada PT. X RU IV Cilacap. Salah satu kilang yang terdapat disana adalah Residual Fluid Catalytic Cracking (RFCC). Bahaya yang terdapat pada RFCC, dapat menyebabkan kecelakaan yang fatal terjadi, Untuk dapat mencegah resiko kecelakaan kerja yang mungkin terjadi kapan saja, diperlukan pengamanan yang baik agar para pekerja terlindungi dari bahaya. SIL merupakan ukuran kinerja sistem keselamatan, dalam hal probabilitas kegagalan sesuai permintaan, dan sistem fuzzy pada LOPA diadopsi untuk menangani ketidakpastian data yang ada sehingga efektif dalam sebuah evaluasi. Telah dilakukan evaluai nilai SIL menggunakan metode FLOPA dan hasil yang didapat adalah terdapat perbedaan nilai SIL antara perhitungan LOPA konvensional dengan FLOPA. Untuk skenario lima hingga tujuh pada FLOPA didapatkan SIL 1, sedangkan pada LOPA konvensional didapatkan SIL 0. Dari hasil FLOPA untuk risk decision, Untuk skenario dua dan empat berada pada kategori Medium dan untuk skenario satu, tiga, lima, enam dan tujuh berada pada kategori High.
===================================================================================================================================
Oil is an important sector in the economy because this sector contributes significantly to GDP, and government revenues. One of the state-owned companies that process oil, namely PT. X RU IV Cilacap. One of the refineries there is Residual Fluid Catalytic Cracking (RFCC). Contained in the RFCC, can cause fatal accidents to occur. To prevent the risk of work accidents that may occur at any time, good protection is needed so that workers are protected from harm. SIL is a measure of safety system performance, in the probability of failure on demand, and the fuzzy system adopted by LOPA to determine the uncertainty of the existing data so that it is effective in evaluation. An evaluation of the SIL value has been carried out using the FLOPA method and the results obtained are the difference in the SIL value between conventional LOPA and FLOPA calculations. For scenarios five to seven in FLOPA, SIL 1 is obtained, while conventional LOPA is SIL 0. From FLOPA results for risk decisions, scenarios two and four are in the medium category and for scenarios one, three, five, six and seven are in the category high.

Item Type: Thesis (Other)
Additional Information: RSF 629.89 Ram e-1 • 2022
Uncontrolled Keywords: RFCC, SIL, LOPA, FLOPA
Subjects: T Technology > T Technology (General) > T55 Industrial Safety
Divisions: Faculty of Industrial Technology and Systems Engineering (INDSYS) > Physics Engineering > 30201-(S1) Undergraduate Thesis