Studi Efektivitas Penggunaan Fluid Viscous Damper (FVD) Pada Gedung Beton Bertulang 10 Lantai Di Kota Jakarta

Sitompul, Andreas Maxwel (2025) Studi Efektivitas Penggunaan Fluid Viscous Damper (FVD) Pada Gedung Beton Bertulang 10 Lantai Di Kota Jakarta. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 5012211055-Undergraduate_Thesis.pdf] Text
5012211055-Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only until 1 April 2027.

Download (12MB) | Request a copy

Abstract

Gempa bumi terjadi akibat tabrakan antar lempeng bumi, pergerakan patahan aktif, aktivitas vulkanik, atau longsoran batu. Hal ini dapat menyebabkan kerugian yang signifikan, termasuk korban jiwa dan kerusakan pada bangunan. Pada tugas akhir ini, akan dilakukan studi efektivitas pada gedung beton bertulang 10 lantai di Kota Jakarta dengan dan tanpa menggunakan Fluid Viscous Damper (FVD) sebagai peredam pada bangunan tahan gempa. Gedung yang ditinjau merupakan gedung perkuliahan 10 lantai dengan struktur utama beton bertulang yang dibangun pada tanah kondisi tanah sedang (SD). Struktur bangunan gedung eksisting tanpa dan dengan FVD akan dianalisis menggunakan standar struktur bangunan gempa SNI 1726:2019 dan SNI 2847:2019. Penggunaan Fluid Viscous Damper (FVD) menunjukkan pengaruh signifikan terhadap perilaku struktur bangunan. Periode fundamental mengalami penurunan sebesar 10,07% pada arah X dan 10,09% pada arah Y. Berdasarkan analisis gempa respons spektra di Kota Jakarta, gaya geser dasar meningkat sebesar 11,16% untuk arah X dan 11,22% untuk arah Y. Analisis tambahan menggunakan rekaman gempa riwayat waktu menunjukkan peningkatan gaya geser dasar sebesar 11,9% pada arah X dan 18% pada arah Y. Selanjutnya, simpangan atap bangunan mengalami penurunan sebesar 32,2% pada arah X dan 29,9% pada arah Y, sementara pada analisis riwayat waktu, penurunan simpangan tercatat sebesar 38% pada arah X dan 22,7% pada arah Y. Penggunaan FVD juga berkontribusi pada penurunan rasio kapasitas elemen struktur, dengan penurunan sebesar 0,35% untuk gaya geser dan 19,1% untuk momen pada balok, serta 20,29% untuk gaya aksial dan 17,94% untuk momen pada kolom. Selain itu, FVD mengurangi percepatan atap hingga 45% pada arah X dan 24% pada arah Y, sementara hasil analisis riwayat waktu menunjukkan penurunan percepatan sebesar 8,9% pada arah X dan 2% pada arah Y. Disipasi Energi oleh struktur berkurang sebesar 36% setelah penggunaan Fluid Viscous Damper (FVD).
========================================================================================================================
Earthquakes occur as a result of plate collisions, active faulting, volcanic activity, or rock avalanches. They can cause significant damage, including loss of life and damage to buildings. In this final project, an effectiveness study will be conducted on a 10-story reinforced concrete building in Jakarta City with and without using Fluid Viscous Damper (FVD) as an earthquake damper. The building in this final project is a 10-story lecture hall with a reinforced concrete structure on medium soil conditions (SD). The existing building structure without and with FVD will be analyzed using the seismic building structure standards SNI 1726:2019 and SNI 2847:2019. The application of the Fluid Viscous Damper (FVD) shows a significant effect on the structure behaviour. The fundamental period was reduced by 10.07% in X-direction and 10.09% in Y-direction. Based on the analysis of earthquake response spectra in Jakarta City, the fundamental shear force increased by 11.16% in X direction and 11.22% in Y direction. Additional analysis using time-series earthquake records showed an increase in the base shear force of 11.9% in the X-direction and 18% in the Y-direction. In addition, the building's roof deflection decreased by 32.2% in the X-direction and 29.9% in the Y-direction, while the time series analysis showed a decrease in deflection of 38% in the X-direction and 22.7% in the Y-direction. The energy dissipation experienced by the structure is reduced by 36% with the use of Fluid Viscous Damper.

Item Type: Thesis (Other)
Uncontrolled Keywords: Bangunan Tahan Gempa, Beton Bertulang, Disipasi Energi, Fluid Viscous Damper, Respons Struktur, Earthquake Resistant Building, Reinforced Concrete, Energy Dissipation, Fluid Viscous Damper, Structure Behaviour
Subjects: T Technology > TA Engineering (General). Civil engineering (General) > TA645 Structural analysis (Engineering)
Divisions: Faculty of Civil Engineering and Planning > Civil Engineering > 22201-(S1) Undergraduate Thesis
Depositing User: Andreas Maxwel S
Date Deposited: 27 Jan 2025 08:55
Last Modified: 27 Jan 2025 08:55
URI: http://repository.its.ac.id/id/eprint/116967

Actions (login required)

View Item View Item