Tambunan, Akas Steven (2025) Studi Numerik Heat Recovery Steam Generator Tipe Horizontal Dengan Penambahan Turning Vane Pada Sisi Inlet Transition Zone Dengan Variasi Jumlah Dan Sudut Kemiringan Vane. Masters thesis, Institut Teknologi Sepuluh Nopember.
![]() |
Text
6007222026-Master_Thesis.pdf - Accepted Version Restricted to Repository staff only until 1 April 2027. Download (9MB) | Request a copy |
Abstract
HRSG (Heat Recovery Steam Generator) adalah salah satu komponen dari combined cycle powerplant yang berguna untuk penukaran panas antara Heat Exchanger (Economizer, Evaporator dan Superheater) dengan gas masuk dalam sistem yang digunakan untuk menghasilkan listrik dalam turbin uap. Dalam sistem HRSG penting untuk memodelkan sistem dengan baik agar dapat membuat distribusi temperatur dan energi dalam sistem dapat tersebar merata selain untuk mencegah adalanya problem lain seperti Localized Overheating, Scaling, dan problem lainnya. Cara yang dapat digunakan untuk memodelkan distribusi energi dengan baik pada sistem HRSG adalah dengan mengatur bukaan damper, Guide Van, dan Corner Angle pada HRSG ketiga komponen ini adalah komponen yang berperan penting dalam mengatur distribusi panas pada zona transisi yaitu zona yang mengalami perluasan dari bagian damper menuju ke bagian heat exchanger itu sendiri. Tugas akhir ini bertujuan untuk mengetahui bagaimana karakterisktik aliran flue gas di HRSG tipe horizontal dengan mengatur jumlah (2 & 3) dan sudut pada Guide Vane (90 & 270) HRSG terhadap distribusi temperatur, distribusi kecepatan dan Pressure drop. Penelitian ini menggunakan metode numerik dengan bantuan software Ansys 2023. Pemodelan yang dilakukan pada penelitian ini adalah tiga dimensi, aliran steady, dengan turbulence model yang digunakan realizable k-epsilon. Domain pemodelan dari penelitian ini dibatasi yaitu domain inlet duct dan domain heat exchanger (Superheater, Evaporizer dan Economizer). Data yang digunakan diambil dari PT Linde Gresik Gases Indonesia. Hasil dari penelitan menunjukkan bahwa peningkatan pada sudut corner angle, dan penambahan jumlah guide vane akan meningkatkan efisiensi pada sistem HRSG sementara efektivitas HRSG akan mengalami peningkatan diakibatkan bertambahnya penyerapan kalor, namun pressure drop yang besar akan menurunkan performa sehingga membuat sistem HRSG menjadi kurang efektif.
==================================================================================================================================
HRSG (Heat Recovery Steam Generator) is one of the components of a combined cycle powerplant that is useful for heat exchange between the Heat Exchanger (Economizer, Evaporator and Superheater) with gas entering the system used to generate electricity in a steam turbine. In the HRSG system, it is important to model the system properly in order to make the temperature and energy distribution in the system evenly distributed in addition to preventing other problems such as Localized Overheating, Scaling, and other problems. The method that can be used to model the energy distribution properly in the HRSG system is to adjust the damper opening, Guide Van, and Corner Angle on the HRSG. These three components are components that play an important role in regulating heat distribution in the transition zone, namely the zone that experiences expansion from the damper section to the heat exchanger section itself. This final project aims to determine the characteristics of flue gas flow in HRSG, the effect of and Guide Vane with incline angle 90 & 270 and also by adding number og guide van HRSG on temperature distribution, velocity distribution and Pressure drop. This study uses a numerical method with the help of Ansys 2023 software. The modelling carried out in this study is three-dimensional, steady flow, with a turbulence model used realizable k-epsilon. The modelling domain of this study is limited to the inlet duct domain and the heat exchanger domain (Superheater, Evaporizer and Economizer). The data used was taken from PT Linde Gresik Gases Indonesia. The results of the study show that increasing the corner angle and increasing the number of guide vanes will increase the efficiency of the HRSG system while the HRSG performance will increase due to increased heat absorption, but the pressure drop will have an effect on reducing performance, making the HRSG system less effective.
Item Type: | Thesis (Masters) |
---|---|
Uncontrolled Keywords: | HRSG, Sudut Kemiringan, Guide Vane, Zona Transisi |
Subjects: | T Technology > TJ Mechanical engineering and machinery > TJ263.5 Boilers (general) T Technology > TJ Mechanical engineering and machinery > TJ265.E23 Thermodynamics. |
Divisions: | Faculty of Industrial Technology and Systems Engineering (INDSYS) > Mechanical Engineering > 21101-(S2) Master Thesis |
Depositing User: | Akas Tambunan |
Date Deposited: | 06 Feb 2025 02:50 |
Last Modified: | 06 Feb 2025 02:51 |
URI: | http://repository.its.ac.id/id/eprint/118361 |
Actions (login required)
![]() |
View Item |