Fardanu, Alif Al (2025) Rancang Bangun Ultrasonik Water Flow Meter Berdaya Rendah dan Murah Berbasis Perbedaan Time of Flight. Other thesis, Institut Teknologi Sepuluh Nopember.
![]() |
Text
Laporan Tugas Akhir_Alif Al Fardanu_5009211084.pdf - Accepted Version Restricted to Repository staff only Download (2MB) | Request a copy |
Abstract
Meteran Air Mekanik yang dipakai saat ini memiliki kekurangan yaitu pemeriksaan masih menggunakan pegawai yang mengecek dari rumah ke rumah sehingga membutuhkan banyak waktu untuk cek meteran air, selain itu tingkat akurasi pengukuran yang cukup rendah dan resiko kehilangan air (loss) yang cukup tinggi. Maka dari itu dibutuhkan meteran air digital yang dapat merekam dan mengirim data penggunaan agar tidak memakan banyak waktu pengecekan. Selain itu, akurasi pengukuran perlu ditingkatkan dan perlu adanya sistem untuk mendeteksi resiko kehilangan air. Pada Penelitian ini, teknologi yang akan dibuat yaitu meteran air ultrasonik yaitu meteran yang meggunakan gelombang ultrasonik dengan mengukur selisih dari Time of Flight. Komponen elektrikal yang digunakan pada alat ini yaitu TDC1000 sebagai chip pengendali ultrasonik yang dirancang khusus untuk aplikasi pengukuran waktu tempuh (Time of Flight) menggunakan gelombang ultrasonik, dan TDC 7200 bertugas melakukan konversi digital dengan resolusi tinggi untuk mengukur durasi waktu antara sinyal awal dan akhir yang diterima dari TDC1000. Spesifikasi dari alat ukur ini yaitu untuk Q1 berada pada 0.0015m3/h, dan Q3 dari alat ukur ini yaitu pada 2.5m3/h. Hasil dari Penelitian ini yaitu memiliki akurasi paling baik sekitar 3.11% dengan standar deviasi atau presisi sebesar 0.028992m3/h, nilai ketidakpastian dari alat ini dengan tingkat kepercayaan 95% yaitu 0.0127m3/h.
========================================================================================================================
The mechanical water meters currently in use have shortcomings: inspections still require staff to check each house, which is time-consuming, in addition to having fairly low measurement accuracy and a high risk of water loss. Therefore, a digital water meter is needed that can record and transmit usage data to reduce inspection time. Furthermore, measurement accuracy needs to be improved, and a system to detect the risk of water loss is necessary. In this research, the technology being developed is an ultrasonic water meter, which utilizes ultrasonic waves by measuring the difference in Time of Flight. The electrical components used in this device are the TDC1000, an ultrasonic controller chip specifically designed for Time of Flight (ToF) applications using ultrasonic waves, and the TDC7200, which performs high-resolution digital conversion to measure the time duration between the start and stop signals received from the TDC1000. The specifications for this meter are a Q1 of 0.0015 m³/h and a Q3 of 2.5 m³/h. The results of this research show a best accuracy of approximately 3.11% with a standard deviation, or precision, of 0.028992 m³/h. The uncertainty value of this device, with a 95% confidence level, is 0.0127 m³/h.
Item Type: | Thesis (Other) |
---|---|
Uncontrolled Keywords: | Meteran Air ultrasonik, Pengukuran, Time of Flight, Time to Digital Converter, Sensing, Time of Flight, Ultrasonic Water Flow Meter, Time to Digital Converter |
Subjects: | Q Science Q Science > QC Physics Q Science > QC Physics > QC100.5 Measuring instruments (General) |
Divisions: | Faculty of Industrial Technology > Physics Engineering > 30201-(S1) Undergraduate Thesis |