Azzahra, Fathma Salsabil (2025) Analisis Dan Assesment Teknologi Pengolahan Air Minum Pada PDAM (Perusahaan Daerah Air Minum) Surya Sembada Menggunakan Metode Teknometrik. Other thesis, Institut Teknologi Sepuluh Nopember.
![]() |
Text
5010211150-Undergraduate_Thesis.pdf - Accepted Version Restricted to Repository staff only Download (8MB) | Request a copy |
Abstract
PDAM Kota Surabaya kerap mendapatkan keluhan dari pelanggan terkait kualitas air yang diterimanya, seperti bau yang kurang sedap dan warna yang keruh sehingga memicu ketidaknyamanan penggunaan air. Ciri kondisi air tersebut menunjukkan kondisi yang tidak memenuhi ketentuan Permenkes. Kondisi air yang tidak memenuhi ketentuan tersebut dapat memungkinkan disebabkan dari proses pengolahan maupun distribusi air. Teknologi yang kurang optimal dalam pengolahan air merupakan salah satu penyebab pada proses pengolahan maupun distribusi air. Pada proses pengolahan air di IPAM masih ditemukan tidak meratanya teknologi karena masih terdapat proses yang dilakukan manual. Oleh karena itu, untuk membandingkan kondisi eksisting, maka dilakukan penelitian ini dengan menerapkan metode teknometrik guna mengukur tingkat kemutakhiran (modern) dari teknologi pengolahan air atau water treatment yang terdapat pada IPAM Ngagel 1 dan 3. Pemilihan metode ini dapat membantu menganalisis dari perspektif yang lebih luas berdasarkan komponen teknologi yang terdiri dari aspek teknologi melalui komponen technoware (mesin atau fasilitas), humanware (SDM), infoware (sistem informasi), dan orgaware (organisasi). Berdasarkan hasil perhitungan TCC diperoleh nilai 0,6746 pada IPAM Ngagel 1 dan nilai 0,6258 pada IPAM Ngagel 3 yang menunjukkan tingkat kontribusi teknologi mencapai semi-modern dengan kategorisasi komponen teknologi yang baik. Nilai TCC yang dihasilkan menunjukkan IPAM memerlukan pengembangan dalam aspek teknologi dan SDM.
====================================================================================================================================
PDAM Kota Surabaya often receives complaints from customers regarding the quality of the water they receive, such as unpleasant odors and dirty colors, which cause discomfort when using the water. These water conditions indicate that they may not meet the standards set by the Ministry of Health regulations. Such condition may be caused by issues in the water treatment or distribution processes. Unoptimized technology in water treatment is one of the causes in both the treatment and distribution processes. In the water treatment process at IPAM, there is still uneven technology because some processes are still done manually. Therefore, to compare the existing conditions, this study was conducted by applying the technometric method to measure the level of modernity of the water treatment technology at IPAM Ngagel 1 and 3. The selection and application of this method can help analyze from a broader perspective based on technological components consisting of technological aspects through technoware (machinery or facilities), humanware (human resources), infoware (information systems), and orgaware (organization). Based on the TCC calculation results, a value of 0.6746 was obtained for IPAM Ngagel 1 and a value of 0.6258 for IPAM Ngagel 3, indicating that the level of technological contribution has reached semi-modern with good categorization of technological components. The TCC values obtained indicate that IPAM requires development in the aspects of technology and human resources.
Item Type: | Thesis (Other) |
---|---|
Uncontrolled Keywords: | Pengolahan Air, Manajemen Teknologi, Teknometrik |
Subjects: | T Technology > T Technology (General) |
Divisions: | Faculty of Industrial Technology > Industrial Engineering > 26201-(S1) Undergraduate Thesis |
Depositing User: | Fathma Salsabil Azzahra |
Date Deposited: | 04 Aug 2025 06:10 |
Last Modified: | 04 Aug 2025 06:10 |
URI: | http://repository.its.ac.id/id/eprint/125514 |
Actions (login required)
![]() |
View Item |