Evitasari, Litani (2022) Pengaruh Penambahan Material Pcm Pada Fasad High-Rise Apartment Di Surabaya Terhadap Performa Termal. Masters thesis, Institut Teknologi Sepuluh Nopember.
![]() |
Text
6013201026-Master_thesis.pdf Restricted to Repository staff only Download (5MB) | Request a copy |
Abstract
Didalam sistem bangunan tinggi, selubung yang salah satunya adalah fasad memiliki peran yang besar dalam penerimaan panas ke dalam bangunan. Jenis material fasad kaca memiliki sifat yang dapat meneruskan panas matahari secara langsung, sehingga panas yang masuk kedalam bangunan terperangkap di dalamnya dan membuat suhu di dalam ruang meningkat. Oleh sebab itu, dibutuhkan adanya penyelesaian atau solusi untuk menurunkan suhu di dalam ruang. Saat ini, teknologi semakin berkembang, sehingga terdapat banyak variasi material yang efektif mengurangi beban pendinginan ruang. Salah satunya yaitu PCM (Phase Change Material) yang dapat digunakan untuk menyimpan energi panas yang masuk melalui selubung bangunan dalam jumlah yang sangat besar. Untuk mengetahui pengaruh material PCM terhadap fasad kaca pada apartemen maka dilakukanlah penelitian. Tujuan dari penelitian ini adalah untuk mengevaluasi dan menganalisis adanya pengaruh penerapan material PCM pada fasad apartemen terhadap suhu di dalam ruang. Metode yang digunakan dalam penelitian ini merupakan metode eksperimental, menggunakan pengukuran lapangan dan simulasi dengan software DesignBuilder. Hasil dari simulasi dengan material PCM didapatkan konfigurasi material yang paling optimal dalam mereduksi termal adalah kombinasi double glass (tinted dan reflektif) dengan PCM gap (Bio-PCM), penurunan suhu yaitu sebesar 1,84 oC. WWR dengan penambahan PCM memiliki pengaruh yang berbanding lurus dengan performa termal, semakin besar WWR, maka semakin tinggi pula penurunan suhu yang dihasilkan. Selain itu, semakin tinggi bangunan, maka semakin rendah penurunan suhu yang dihasilkan. Pengaruh performa termal di dalam bangunan terhadap orientasi pada WWR 60% dengan double glass dan gap Bio-PCM yaitu orientasi timur lebih baik dalam mengurangi panas sekitar 2-8 oC. dibanding dengan orientasi barat, utara dan selatan.
=====================================================================================================================================
In high-rise building systems, the envelope, one of which is the facade, has a major role in the reception of heat into the building. This type of glass facade material has properties that can transmit solar heat directly, so that the heat that enters the building is trapped inside and makes the temperature in the room increase. Therefore, it is necessary to have a solution to reduce the temperature in the building. Currently, technology is developing, so there are many variations of materials that effectively reduce the cooling load of the space. One of them is PCM (Phase Change Material) which can be used to store very large amounts of heat energy that enters through the building envelope. To determine the effect of PCM material on the glass facade in the apartment, a study was carried out. The purpose of this study was to evaluate and analyze the effect of applying PCM material on the apartment facade to the temperature in the room. The method used in this study is an experimental method, using field measurements and simulations with DesignBuilder software. The results of the simulation with PCM material obtained that the most optimal material configuration for thermal reduction is a combination of double glass (tinted and reflective) with PCM gap (Bio-PCM), the temperature reduction is 1.84 oC. WWR with the addition of PCM has an effect that is directly proportional to the thermal performance, the greater the WWR, the higher the resulting decrease in temperature. In addition, the taller the building, the lower the resulting temperature drop. The effect of thermal performance inside the building on the orientation at 60% WWR with double glass and gap Bio-PCM, i.e. eastern orientation is better at reducing heat around 2-8 oC. compared to the west, north and south orientations.
Item Type: | Thesis (Masters) |
---|---|
Uncontrolled Keywords: | Fasad Apartemen, Thermal Properties, Tropis, Apartment facade, Thermal properties, Tropical |
Subjects: | N Fine Arts > NA Architecture N Fine Arts > NA Architecture > NA6600 Education buildings |