Nurafiatullah, Nurafiatullah (2014) Analisis Aliran Daya Harmonisa Dengan Metode ZBR Pada Sistem Distribusi Tiga Fasa Weakly Meshed. Other thesis, Institut Teknologi Sepuluh Nopember.
![]() |
Text
2210100178_Undergraduate_Thesis.pdf Restricted to Repository staff only Download (1MB) | Request a copy |
Abstract
Kualitas daya listrik memiliki peranan yang sangat penting pada era teknologi seperti saat ini. Perkembangan teknologi yang begitu pesat telah mendorong terciptanya pemakaian beban non-linier sehingga dapat mengakibatkan peristiwa harmonisa, yaitu suatu gangguan sistem tenaga listrik yang berupa distorsi pada bentuk gelombang tegangan dan arus pada sistem tenaga listrik. Timbulnya peristiwa harmonisa dalam suatu sistem tenaga listrik ini dapat menimbulkan rugi-rugi dalam penyaluran energi listrik serta dapat menyebabkan kerusakan pada peralatan listrik. Karena dampak yang ditimbulkan dari peristiwa harmonisa tersebut cukup merugikan, maka diperlukan suatu analisis penyebaran harmonisa dalam sistem distribusi, sehingga besar dan tingkatan harmonisa pada setiap lokasi tertentu dapat diketahui. Pada sistem distribusi weakly meshed, yaitu sistem distribusi yang tidak murni radial, analisis aliran daya harmonisa dilakukan dengan menggunakan metode ZBR melalui proses modifikasi topologi jaringan dalam menentukan aliran dayanya. Dari hasil simulasi dapat terlihat bahwa ketika 2 bus dari sistem distribusi radial dihubungkan, terjadi perubahan nilai tegangan yang mengakibatkan perubahan tingkatan THDv (Total Harmonic Distortion) dari gelombang tegangan pada semua bus. Dari hasil simulasi tersebut terlihat juga bahwa dengan error maksimal sebesar 10,13214 %, semakin besar perbedaan tegangan antara kedua bus yang dihubungkan maka akan semakin besar pula persentase perubahan THDv sistemnya. Hal ini bisa dilihat dari hasil simulasi saat Bus 10 dan Bus 13 dihubungkan.
============================================================================================================================
Electric power quality has an important role in the era of technology like nowadays. This vast technology development makes the uses of non-linear loads which can cause harmonics, one of a fault in a electric power system that can cause some distortion in a current or a voltage waveforms in the electric power system. This harmonics phenomena can cause a losses in a power distribution system and can cause failures on the devices. Because the effects on this phenomena can harm the power system, the harmonic loadflow analysis in a distribution system is needed so that the magnitudes and the harmonic levels in each location could be calculated. In a weakly meshed distribution system, which is a distribution system that isn’t purely radial, this harmonic analysis is done by using ZBR method through a network topology modification process in order to determine it’s loadflow. In the simulation results, it could be seen that if 2 buses of the radial distribution system is connected one another, it could make a voltage changes that can cause THDv (Total Harmonic Distortion) level changes in every buses. From that simulation also it could be seen that with a maximal error value about 10,13214 %, when the voltage differences between the connected bus become higher, the THDv level percentage changes also become higher. This result can be seen in the simulation when Bus 10 and Bus 13 are connected.
Item Type: | Thesis (Other) |
---|---|
Uncontrolled Keywords: | harmonisa, jaringan distribusi weakly meshed, metode ZBR, modifikasi topologi jaringan, THDv harmonics, weakly meshed distribution system, ZBR Method, network topology modification, THDv |
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK5105.543 Routers (Computer networks) |
Divisions: | Faculty of Industrial Technology > Electrical Engineering > 20201-(S1) Undergraduate Thesis |
Depositing User: | Eko Sulistiono |
Date Deposited: | 22 Sep 2025 03:43 |
Last Modified: | 22 Sep 2025 03:43 |
URI: | http://repository.its.ac.id/id/eprint/128336 |