Evaluasi Dosis Jaringan Glandular Payudara Menggunakan Film XR-QA2 Dengan In-House Phantom Pada Pemeriksaan Computed Tomography

Diaz, Regina (2022) Evaluasi Dosis Jaringan Glandular Payudara Menggunakan Film XR-QA2 Dengan In-House Phantom Pada Pemeriksaan Computed Tomography. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 01111840000084-Undergraduate_Thesis.pdf] Text
01111840000084-Undergraduate_Thesis.pdf
Restricted to Repository staff only

Download (1MB) | Request a copy

Abstract

Penelitian ini dilakukan dengan tujuan untuk mengetahui estimasi dosis yang diterima oleh jaringan glandular payudara pada pemeriksaan Computed Tomography (CT) Thorax Examination di bawah mode manual dan Automatic Exposure Control (AEC) menggunakan in-house phantom. Pada penelitian ini dosimeter yang digunakan adalah film XR-QA2. Pada mode manual tegangan yang digunakan adalah 80 dan 120 kilo Volt peak (kVp) dan arus tetap 100 mili ampere second (mAs), pada mode AEC digunakan nilai tegangan yang sama dengan mode manual, selain itu dilakukan juga analisis pengaruh arus terhadap dosis dengan variasi arus 100, 200, 300, 400 mAs dan tegangan tetap 80 kVp. Dari parameter-parameter berikut didapatkan nilai Volume Computed Tomography Dose Index (CTDIvol) sebesar 2,80 pada tegangan 80 kVp dan 8,85 mGy pada tegangan 120 kVp untuk mode manual dan AEC. Pada film XR-QA2 terlebih dahulu dilakukan uji sentivitas dan didapatkan bahwa kanal merah lebih sensitif daripada kanal hijau dan biru. Kurva kalibrasi diplot dengan hanya menggunakan kanal merah saja selanjutnya dilakukan evaluasi grafik polynomial fitting. Melalui persamaan yang didapatkan dari polynomial fitting didapatkan nilai dosis dengan mode manual pada tegangan 80 kVp sebesar 6,47 – 6,75 mili Gray (mGy) dan tegangan 120 kVp sebesar 15,75 – 18,43 mGy. Pada mode AEC diperoleh nilai dosis pada tegangan 80 kVp sebesar 4,92 – 5,34 mGy dan tegangan 120 kVp sebesar 11,15 – 14,68 mGy. Nilai dosis dari data variasi arus diperoleh 6,47 – 6,75 mGy pada 100 mAs, dosis 9,19 – 10,91 mGy pada 200 mAs, dosis 12,95 – 13,54 mGy pada 300 mAs dan dosis 19,44 – 20,55 mGy pada arus 400 mAs. Nilai dosis pada jaringan glandular dengan mode AEC diperoleh nilai yang lebih kecil dibandingkan dengan pemeriksaan mode manual. Data variasi arus memiliki pengaruh terhadap nilai dosis yang diperoleh, semakin besar arus yang diberikan maka semakin besar pula dosis yang diterima oleh jaringan glandular.
=================================================================================================================================
This study was conducted to investigate the estimated dose received by the breast glandular tissue on the Computed Tomography (CT) Thorax Examination under manual mode and Automatic Exposure Control (AEC) using an in-house phantom. In this study, the dosimeter used was XR-QA2 film. In manual mode, the voltage used is 80 and 120 kilo Volt peak (kVp) and a fixed current of 100 mili ampere second (mAs); in AEC mode, the same voltage is used as in manual mode. The effect of tube current on glandular tissue dose is also analyzed with variations of tube currents 100, 200, 300, and 400 mAs and a fixed voltage of 80 kVp. From the following parameters, the Volume Computed Tomography Dose Index (CTDIvol) value is 2.80 at a voltage of 80 kVp and 8.85 mGy at a voltage of 120 kVp for manual and AEC modes. In the XR-QA2 film, a sensitivity test was first carried out, and it was found that the red channel was more sensitive than the green and blue channels. The calibration curve is plotted using only the red channel, and then the polynomial fitting graph is evaluated. Through the equation obtained from the polynomial fitting, the dose value in manual mode at a voltage of 80 kVp is 6.47 – 6.75 mGy, and a voltage of 120 kVp is 15.75 – 18.43 mGy. In AEC mode, the dose value at 80 kVp is 4.92 – 5.34 mGy, and 120 kVp is 11.15 – 14.68 mGy. The dose values from the current variation data obtained were 6.47 – 6.75 mGy at 100 mAs, doses 9.19 – 10.91 mGy at 200 mAs, doses 12.95 – 13.54 mGy at 300 mAs, and doses 19.44 – 20.55 mGy at 400 mAs current. The dose value in glandular tissue with AEC mode obtained a smaller value than the manual mode. The tube current also influences the dose value obtained; the greater the current given, the greater the dose received by the glandular tissue.

Item Type: Thesis (Other)
Uncontrolled Keywords: AEC, CTDIvol, Computed Tomography, Film XR-QA2, Computed Tomography, XR-QA2 Film
Subjects: Q Science > QC Physics > QC451 Spectroscopy
Divisions: Faculty of Science and Data Analytics (SCIENTICS) > Physics > 45201-(S1) Undergraduate Thesis
Depositing User: Mr. Marsudiyana -
Date Deposited: 08 Oct 2025 06:36
Last Modified: 08 Oct 2025 06:36
URI: http://repository.its.ac.id/id/eprint/128509

Actions (login required)

View Item View Item