Prayitno, Audiena Gelung (2022) Evaluasi Pengaruh Tegangan Dan Arus Pada Modalitas Mammografi Terhadap Dosis Dan Kualitas Citra Menggunakan Film XR-QA2 Dan In House Phantom Payudara. Other thesis, Institut Teknologi Sepuluh Nopember.
![]() |
Text
01111840000085-Undergraduate_Thesis.pdf Restricted to Repository staff only Download (1MB) | Request a copy |
Abstract
Pencitraan mammografi digunakan untuk mendeteksi kelainan pada jaringan payudara berdasarkan tingkat keabuan suatu citra. Oleh karena itu, modalitas mamografi memerlukan jaminan kualitas untuk mempertahankan citra yang dihasilkan. Untuk mengatasi permasalahan di atas, maka dilakukan penelitian pengembangan fantom mammografi berdasarkan data aktual mamografi (MG). Penelitian telah dilakukan untuk mengevaluasi ukuran nozzle terhadap kualitas gambar pada tegangan tetap dan pengaruh variasi tegangan tabung dan modulasi arus tabung pada kualitas gambar in-house breast phantom. Selanjutnya, penelitian ini bertujuan untuk mengevaluasi pengaruh variasi tegangan tabung mammografi terhadap dosis yang diterima jaringan kelenjar menggunakan metode manual dan Automatic Exposure Control (AEC) dengan variasi tegangan 23, 28, dan 35 kV dan arus konstan 100 mAs. Selanjutnya evaluasi kualitas citra dianalisis dengan parameter Signal to Noise Ratio (SNR), Contrast to Noise Ratio (CNR), dan Modulation Transfer Function (MTF), serta hasil dosimetri pada jaringan glandular. Kualitas citra terbaik diperoleh pada ukuran nozzle 0,2 mm dengan tegangan 28 kV menggunakan mode manual. Hasil SNR menunjukkan bahwa yang paling signifikan adalah pada 35 kV, dan nilai SNR terbesar dicapai pada ukuran nozzle 0,2 mm, sedangkan nilai SNR terbesar diperoleh untuk jaringan kulit. Sedangkan nilai CNR terbesar diperoleh pada 28 kV dengan ukuran nozzle 0,2 mm menggunakan mode manual. Selain itu, nilai MTF terbesar terdapat pada Polylactic Acid (PLA) pada ukuran nozzle 0,4 mm dengan 35 kV menggunakan mode manual. Akhirnya, hasil dosimetri pada jaringan kelenjar diperoleh nilai dosis rata-rata pada 23 kV, 28 kV, dan 35 kV berturut-turut adalah 2,85 mGy 0,97 mGy, dan 9,75 mGy. =================================================================================================================================
Mammography imaging is used to detect abnormalities in breast tissue based on the gray level of an image. Therefore, mammography modalities require quality assurance to maintain the resulting image. To overcome the problems above, research on the development of phantom mammography was carried out based on actual mammography (MG) data. Research has been carried out to evaluate nozzle size on image quality at constant voltage and the effect of tube voltage variation and tube current modulation on image quality of in-house breast phantom. Furthermore, this study aims to evaluate the effect of variations in mammographic tube voltage on the dose received by glandular tissue using manual and Automatic Exposure Control (AEC) methods with variations in voltage of 23, 28, and 35 kV and a constant current of 100 mAs. Furthermore, the evaluation of image quality was analyzed with the parameters Signal to Noise Ratio (SNR), Contrast to Noise Ratio (CNR), and Modulation Transfer Function (MTF), as well as dosimetry results in glandular tissue. The best image quality is obtained at a nozzle size of 0.2 mm with a voltage of 28 kV using manual mode. The SNR results show that the most significant is at 35 kV, and the largest SNR value is achieved at a nozzle size of 0.2 mm, while the largest SNR value is obtained for skin tissue. While the largest CNR value was obtained at 28 kV with a nozzle size of 0.2 mm using manual mode. In addition, the largest MTF value is found in Polylactic Acid (PLA) at a nozzle size of 0.4 mm with 35 kV using manual mode. Finally, dosimetry results on glandular tissue were obtained; the average dose at 23 kV, 28 kV, and 35 kV was 2.85 mGy, 28 kV was 0.97 mGy, and 35 kV was 9.75 mGy.
Item Type: | Thesis (Other) |
---|---|
Uncontrolled Keywords: | In house phantom, Mammografi, Payudara, Breast, Mammography |
Subjects: | Q Science > QC Physics |
Divisions: | Faculty of Science and Data Analytics (SCIENTICS) > Physics > 45201-(S1) Undergraduate Thesis |
Depositing User: | Mr. Marsudiyana - |
Date Deposited: | 08 Oct 2025 06:44 |
Last Modified: | 08 Oct 2025 06:44 |
URI: | http://repository.its.ac.id/id/eprint/128511 |