Kaji Numerik Distribusi Temperatur Pada Ruangan BB 203 D III Teknik Mesin FTI-ITS

Fahresi, Fahmi (2007) Kaji Numerik Distribusi Temperatur Pada Ruangan BB 203 D III Teknik Mesin FTI-ITS. Diploma thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 2104030043-Undergraduate_Thesis.pdf] Text
2104030043-Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only

Download (5MB) | Request a copy

Abstract

Penyegaran udara merupakan suatu fenomena yang penting dalam ilmu pengkondisian udara, dan dalam tugas akhir ini akan ditentukan distribusi temperatur yang terjadi dalam ruangan, dimana analisis distribusi temperatur ini merupakan bagian dari analisis pengkondisian udara. Metoda yang digunakan dalam penganalisaan distribusi pada ruangan adalah metoda numerik, yaitu dengan membagi daerah yang dianalisis menjadi beberapa bagian sub kecil - kecil penerapan komputer khususnya program FLUENT 6.2 ini digunakan untuk memudahkan dalam proses iterasi. Dari hasil numeric yang di peroleh, temperatur terbesar terletak pada nodal paling atas, di tengah ruangan yaitu 287,00568 K dan temperature terkecil terletak pada aliran masuk yaitu 287,00021 K
==================================================================================================================================
Air freshening is an important phenomenon in air conditioning science, and in this final project the temperature distribution that occurs in the room will be determined, where the analysis of this temperature distribution is part of the air conditioning analysis. The method used in analyzing the distribution in the room is a numerical method, namely by dividing the analyzed area into several small sub-parts. The application of a computer, especially the FLUENT 6.2 program, is used to facilitate the iteration process. From the numerical results obtained, the highest temperature is located at the topmost node, in the center of the room, namely 287.00568 K and the lowest temperature is located at the inlet flow, namely 287.00021 K

Item Type: Thesis (Diploma)
Additional Information: RSM 518 Fah k-1 2007 (weeding)
Uncontrolled Keywords: distribusi, temperatur, ruangan; istribution, temperature, room
Subjects: Q Science > QC Physics > QC 611.97.T46 Temperature effects. Including transition temperature
Divisions: Faculty of Industrial Technology > Mechanical Engineering > 21401-(D3) Diploma 3