Nisa, Rifka Choirun (2022) Pengaruh Besar Tegangan Electrostatic Precipitator (ESP) Jenis Wire-To-Plat Terhadap Pengukuran Reduksi Gas Co. Other thesis, Institut Teknologi Sepuluh Nopember.
|
Text
01111840000025-Undregraduate_thesis.pdf Restricted to Repository staff only Download (1MB) | Request a copy |
Abstract
Tingginya kadar polusi di Indonesia dan betapa berbahayanya gas karbon monoksida (CO) untuk jangka panjang. Seiring perkembangan zaman, telah banyak inovasi yang dikembangkan untung mengurangi tingginya kadar CO. Salah satunya yaitu pemanfaatan Eelctrostatic Precipitator (ESP) yang dapat mengurangi kadar polutan menggunakan tegangan tinggi dan laju aliran gas tertentu dan ramah lingkungan. Pada penelitian ini telah dilakukan pengukuran reduksi dengan menggunakan Gas CO. Pengukuran reduksi dilakukan dengan mengalirkan asap dari tabung inlet menuju tabung outlet pada Electrostatic Precipitator (ESP). Pada perjalannya dari inlet menuju outlet, gas akan direduksi pada sistem Electrostatic Precipitator (ESP) yang didalamnya terdapat elektroda negatif dan positif untuk melakukan ionisasi, kemudian dilakukan pengambilan data dengan melihat kadar gas sebelum dan sesudah exhausting. Pada penelitian ini didapatkan pengukuran reduksi tertinggi yaitu pada saat tegangan 25 kV dengan laju aliran gas 4-6 liter/menit sebesar 73,472 %. Dan pengukuran reduksi terendah yaitu pada saat tegangan 10 kV dengan laju aliran gas 6-8 liter/menit didapatkan reduksi sebesar 42,350 %. Dari hasil penelitian ini dapat disimpulkan bahwa tegangan dan laju aliran gas sangat berpengaruh pada besar reduksi dan tegangan sifatnya berbanding lurus dengan reduksi, namun laju aliran gas sifatnya berbanding terbalik dengan reduksi.
===================================================================================================================================
The high level of pollution in Indonesia and how dangerous carbon monoxide (CO) gas is in the long term. Along with the times, many innovations have been developed to reduce high levels of CO. One of them is the use of Electrostatic Precipitator (ESP) which can reduce pollutant levels using high voltage and certain gas flow rates and is environmentally friendly. In this research, reduction measurements have been carried out using CO gas. The reduction measurement is carried out by flowing smoke from the inlet tube to the outlet tube on the Electrostatic Precipitator (ESP), on its way from the inlet to the outlet, the gas will be reduced to the Electrostatic Precipitator (ESP) system in which there are negative and positive electrodes for ionization, then taking data by looking at gas levels before and after exhausting. In this study, the highest reduction measurement was obtained, namely when the voltage was 25 kV with a gas flow rate of 4-6 liter/minute, the gas reduction was 73,472 %. And the lowest reduction measurement is at a voltage of 10 kV with a gas flow rate of 6-8 liter/minute, a reduction of 42,35 % is obtained. From the results of this study, it can be concluded that the voltage and gas flow rate greatly affect the reduction and the voltage is directly proportional to the reduction, but the gas flow rate is inversely proportional to the reduction.
| Item Type: | Thesis (Other) |
|---|---|
| Uncontrolled Keywords: | CO, Debit, Electrostatic Precipitator, Polutan, Tegangan, CO, Electrostatic Precipitator, Flowrate, Pollutant, Voltage |
| Subjects: | Q Science > QC Physics Q Science > QC Physics > QC100.5 Measuring instruments (General) |
| Divisions: | Faculty of Science and Data Analytics (SCIENTICS) > Physics > 45201-(S1) Undergraduate Thesis |
| Depositing User: | Mr. Marsudiyana - |
| Date Deposited: | 16 Dec 2025 06:23 |
| Last Modified: | 16 Dec 2025 06:23 |
| URI: | http://repository.its.ac.id/id/eprint/128986 |
Actions (login required)
![]() |
View Item |