Studi Efektivitas Penggunaan Fluid Viscous Damper (FVD) Dengan Struktur Baja Komposit Pada Gedung Pendidikan Di Surabaya

Heryadi, Kevin Putra (2026) Studi Efektivitas Penggunaan Fluid Viscous Damper (FVD) Dengan Struktur Baja Komposit Pada Gedung Pendidikan Di Surabaya. Other thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 5012221091-Undergraduate_Thesis.pdf] Text
5012221091-Undergraduate_Thesis.pdf - Accepted Version
Restricted to Repository staff only

Download (35MB) | Request a copy

Abstract

Dalam lima tahun terakhir, tercatat setidaknya terjadi 113 gempa bumi di Indonesia yang menelan 755 orang korban jiwa serta kerusakan pada 1.893 fasilitas pendidikan. Kota Surabaya, sebagai salah satu kota metropolitan dengan ekosistem pendidikan yang maju, juga memiliki potensi gempa bumi yang signifikan karena berada di atas patahan aktif Sesar Kendeng segmen Waru–Surabaya, dengan potensi magnitudo hingga 6,5. Pada tugas akhir ini, akan dilakukan studi efektivitas pada gedung baja komposit 12 lantai di Kota Surabaya yang dibangun pada kondisi tanah lunak (SE) dengan dan tanpa menggunakan Fluid Viscous Damper (FVD) sebagai peredam pada bangunan tahan gempa. Struktur bangunan gedung baja komposit tanpa dan dengan FVD akan dianalisis menggunakan standar struktur bangunan gempa SNI 1726:2019 dan SNI 1729:2019. Penggunaan Fluid Viscous Damper (FVD) menunjukkan pengaruh signifikan terhadap perilaku struktur bangunan. Struktur dengan FVD diperoleh berat lebih ringan 13% namun biaya material struktur atas meningkat sebesar 5,7%. Di sisi lain kebutuhan dan biaya material tiang pondasi dapat direduksi hingga 21%. Periode fundamental mengalami penurunan sebesar 4,1% pada arah-X dan peningkatan 1,46% pada arah-Y. Berdasarkan analisis gempa respons spektra di Kota Surabaya, gaya geser dasar direduksi sebesar 19% untuk arah-X dan 14,8% untuk arah-Y. Selanjutnya, simpangan antar lantai bangunan mengalami penurunan sebesar 33,55% pada arah-X dan 18,10% pada arah-Y, sementara pada analisis riwayat waktu, penurunan simpangan tercatat sebesar 23,9% pada arah-X dan 12,8% pada arah-Y. Selain itu, FVD mengurangi percepatan atap hingga 29,9% pada arah-X dan 16,9% pada arah-Y, sementara hasil analisis riwayat waktu menunjukkan penurunan percepatan sebesar 14,3% pada arah-X dan 8,5% pada arah-Y. Penggunaan FVD dapat mendisipasikan energi sebesar 37,3% pada 7 rekaman gempa yang digunakan sehingga kolom dan balok dapat bekerja secara elastis.
==================================================================================================================================
In the last five years, Indonesia has recorded at least 113 earthquakes that resulted in 755 fatalities and damaged 1,893 educational facilities. Surabaya, as a major metropolitan city with a strong educational ecosystem, faces significant seismic risk due to its location on the active Kendeng Fault segment Waru–Surabaya, which can generate earthquakes up to magnitude 6.5. This study evaluates the effectiveness of Fluid Viscous Dampers (FVD) in a 12-story composite steel building constructed on soft soil (Site Class SE) in Surabaya, analyzed with and without FVD in accordance with SNI 1726:2019 and SNI 1729:2019. The FVD equipped structure shows a 13% reduction in superstructure weight, although the superstructure material cost increases by 5.7%. Conversely, the material requirements and costs for pile foundations are reduced by up to 21%. The use of FVD demonstrates significant improvements in seismic performance. The fundamental period decreases by 4.1% in the direction X and increases by 1.46% in the direction Y. Response spectrum analysis indicates reductions in base shear of 19% in the direction X and 14.8% in the direction Y. Interstory drift decreases by 33.55% in the direction X and 18.10% in the direction Y, while time-history analysis shows drift reductions of 23.9% in the direction X and 12.8% in the direction Y. Roof acceleration is also reduced by 29.9% in the direction X and 16.9% in the direction Y, with time-history results showing reductions of 14.3% and 8.5%, respectively. Overall, FVD dissipates up to 37.3% of seismic energy across seven earthquake records, enabling beams and columns to remain within the elastic range and demonstrating its effectiveness as a seismic control strategy for composite steel buildings in high-risk urban areas.

Item Type: Thesis (Other)
Uncontrolled Keywords: Bangunan Tahan Gempa, Fluid Viscous Damper, Linear Time History, Struktur Baja, Surabaya, Steel Structure, Earthquake Resistant, Fluid Viscous Damper, Linear Time History, Surabaya
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
T Technology > TA Engineering (General). Civil engineering (General) > TA645 Structural analysis (Engineering)
T Technology > TH Building construction
T Technology > TH Building construction > TH1095 Earthquakes and building
Divisions: Faculty of Civil, Planning, and Geo Engineering (CIVPLAN) > Civil Engineering > 22201-(S1) Undergraduate Thesis
Depositing User: Kevin Putra Heryadi
Date Deposited: 21 Jan 2026 06:02
Last Modified: 21 Jan 2026 06:02
URI: http://repository.its.ac.id/id/eprint/129954

Actions (login required)

View Item View Item