MODIFIKASI PERENCANAAN HOTEL FAVE KETINTANG SURABAYA DENGAN MENGGUNAKAN SISTEM STRUKTUR CONCENTRICALLY BASED FRAME DAN STEEL SLIT DAMPER

NURAINI, SANTI (2016) MODIFIKASI PERENCANAAN HOTEL FAVE KETINTANG SURABAYA DENGAN MENGGUNAKAN SISTEM STRUKTUR CONCENTRICALLY BASED FRAME DAN STEEL SLIT DAMPER. Undergraduate thesis, Institut Teknologi Sepuluh Nopember.

[thumbnail of 3113106048-Undergraduate_Theses.pdf]
Preview
Text
3113106048-Undergraduate_Theses.pdf - Published Version

Download (17MB) | Preview

Abstract

Salah satu alat kontrol pasif pada struktur yang
berdasarkan penggunaan material bercelah untuk mengurangi
getas adalah Steel Slit Damper (Peredam Celah). Alat ini dapat
dipasang pada bermacam-macam struktur: gedung bertingkat
tinggi, menara, bentangan yang panjang, dan jembatan. Tujuan
utama pemasangan Steel Slit Damper pada gedung tinggi untuk
mengurangi goyangan gedung akibat angin, pada menara untuk
mengurangi goyangan akibat gempa bumi dan angin, pada
struktur berbentang panjang untuk mengurangi getaran akibat lalu
lintas, dan pada jembatan untuk mengurangi goyangan akibat
angin atau getaran akibat lalu lintas (Lisa, 2012). Dengan adanya
penelitian-penelitian sebelumnya mengenai Steel Slit Damper
perlu adanya perencanaan pada bangunan gedung bertingkat
dengan menggunakan Steel Slit Damper sehingga dapat diketahui
bagaimana perilaku struktur yang terjadi jika diaplikasikan pada
sebuah bangunan gedung dan tidak hanya ditinjau pada portal
bertingkat saja.
Telah dilakukan perhitungan modifikasi perencanaan
struktur bangunan Fave Hotel Ketintang Surabaya menggunakan
sistem (Concentrically Braced Frames) dengan menggunakan
Steel Slit Damper. Perhitungan struktur yang dilakukan mengacu
pada SNI 03-1729-2002 “Tata Cara Perencanaan Struktur Baja
Untuk Bangunan Gedung, Badan Standarisasi Nasional”, SNI 03-
1726-2012 “Tata Cara Perencanaan Ketahanan Gempa Untuk
Rumah dan Gedung”, SNI 1727-2013 “Beban Minimum Untuk
Perancangan Bangunan Gedung dan Struktur Lain”. Pemodelan
dan analisis struktur dilakukan dengan program bantu SAP 2000.
Dari analisa dan hasil perhitungan diperoleh hasil, yaitu:
tebal pelat atap dan lantai 9 cm, dimensi balok induk lantai ada 3
macam yaitu WF500.300.11.15,WF500.200.10.16 dan
WF300.150.5,5.8, dimensi balok induk atap ada 3 macam yaitu
WF500.200.10.16,WF450.300.10.15 dan WF250.125.6.9,
dimensi kolom lantai 1-6 KC800.450.16.38, dimensi kolom lantai
7-12 KC588.300.12.20, dimensi bressing terdiri dari bressing
dengan portal 3,4 m menggunakan WF200.150.6.9 dan portal 7 m
menggunakan WF200.200.8.12, dimensi SSD WF350.350.14.22,
base plate menggunakan fixed plate BMK-17 dari katalog
PT.Gunung Garuda. Sambungan struktur utama direncanakan
sebagai sambungan kaku dengan baut fub 825 Mpa. Perencanaan
pondasi menggunakan tiang pancang beton pracetak diameter 50
cm dengan kedalaman 14 m. Sloof ukuran 40 cm x 60 cm dengan
tulangan utama 8D22 dan tulangan geser Ø12-300. ========== One of the tools in the passive control structure, which is
based on the use of slotted to reduce the brittle material, is Steel
Slit Damper (Silencer Gap). This tool can be mounted on various
structures such as, a high-rise building, a tower, a long stretch,
and bridges. The main purpose in installing Steel Slit Damper on
high buildings is to reduce the sway of the building due to the
wind. On the tower, it will reduce the oscillation due to
earthquake and wind. On the other hands, installing it on the long
span structure will reduce vibration caused by traffic, as in the
bridge, I can reduce wobble due to wind or vibrations due to last
cross (Lisa, 2012). Having previous studies about Steel Slit, it
needs development planning on a storey buildings by using Slit
Steel Damper, therefore, we can seen how is the behavior of
structures that occur when we apply it to a non-storey building
and not only review on the storied portal.
The calculation on the structural design modification
building of Ketintang Fave Hotel Surabaya (Concentrically
Braced Frames), has been done by using Slit Steel Damper.
Structure calculations are referred to the SNI 03-1729-2002
"Planning Procedures For Building Steel Structure, National
Standardization Agency", SNI 03-1726-2012 "Resisting Planning
Standard from Earthquake for building structure", SNI 1727-
2013 "Minimum load for Designing Buildings and Other
vi
structures ". Modeling and structural analysis performed by the
auxiliary program SAP 2000.
From the analyzing and calculating, the results obtained
are: the roof and floor slab with thickness of 9 cm; the dimensions
of the floor beam there are 3 kinds WF500.300.11.15,
WF500.200.10.16 and WF300.150.5,5.8; the dimensions of the
roof beam there are 3 kinds WF500.200.10.16; WF450.300.10.15
and WF250.125.6.9, column dimensions KC800.450.16.38 floors
1-6, 7-12 floor KC588.300.12.20 column dimensions; dimension
bressing WF200.150.6 .9 and WF200.200.8.12; dimensions SSD
WF350.350.14.22,; and a base plate using a fixed plate BMK-17
from the catalog PT. Gunung Garuda. Splicing the main structure
is planned as a rigid connection with bolt fu
b 825 Mpa.
Foundation design using precast concrete pile with diameter of
50 cm and a depth of 14 m. it also has Sloof with size of 40 cm x
60 cm with the main reinforcement and shear reinforcement Ø12-300 8D22.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Steel Slit Damper, Concentrically Braced Frame, Struktur Baja, Steel Slit Damper, Concentrically Braced Frame, Steel Structure
Subjects: T Technology > TA Engineering (General). Civil engineering (General) > TA645 Structural analysis (Engineering)
T Technology > TA Engineering (General). Civil engineering (General) > TA681 Concrete construction
Divisions: Faculty of Civil Engineering and Planning > Civil Engineering > 22201-(S1) Undergraduate Thesis
Depositing User: - Davi Wah
Date Deposited: 05 Jan 2017 03:59
Last Modified: 27 Dec 2018 03:14
URI: http://repository.its.ac.id/id/eprint/1323

Actions (login required)

View Item View Item